FB400 / FB900
1 /12Pages

FB400 / FB900

FB400 / FB900
1 /12Pages

Catalog excerpts

FB400 / FB900-2

High Performance Digital controller The FB Series is a high performance process controller with a more advanced Brilliant II PID, autotuning, advanced tuning, selectable sampling cycle time of 0.05/0.1/0.25 seconds and 0.1 % of accuracy in short depth housing. • When the sampling time is set to 0.1 seconds or 0.05 seconds, the following input ranges cannot be used : Pt100 -100.00 to +100.00°C, -199.99 to +199.99°F JPt100 -100.00 to +100.00°C, -199.99 to +199.99°F Versatility and easy maintenance in 60mm Depth 1 Panel space saving: 60mm depth The FB Series has very short depth as a 1/8 or 1/4...

 Open the catalog to page 2
FB400 / FB900-3

A more advanced Brilliant II PID with Enhanced Autotuning Brilliant II PID Control Selectable PID control algorithm PV derivative type PID control Deviation derivative type PID control Follow-up PID control algorithm is selectable in the FB Series to achieve the most precise control for various applications. PV Derivative PID : suitable for fixed setpoint control (Factory setting) Deviation Derivative PID : suitable for ramp control using ramp-to-setpoint function and cascade control. Most adaptive to conventional ramp-to-setpoint control Most adaptive to conventional fixed value control sampling...

 Open the catalog to page 3
FB400 / FB900-4

User-friendly key-operation and display 1 Direct Function Keys Three direct function keys enable one-touch operation on frequently used functions such as Auto/Manual, Monitoring display scroll, and Memory area selection. The keys can also be configured as RUN/STOP, Remote/Local, and Auto/Manual keys. Monitoring display select R/S Pressing the MODE select key for 2 sec enables the same mode selection as in the conventional REX-F900/F400. Memory area select Memory area select PID/AT Auto/Manual Monitoring display select Auto/Manual RUN/STOP Remote/Local • Can be set to any of the following selection...

 Open the catalog to page 4
FB400 / FB900-5

Temperature uniformity and stability 1 Temperature Uniformity at Ramp-up Auto-temperature-rise with learning function achieves temperature uniformity at ramp-up without partial thermal expansion even when multiple FB Series controllers are connected. Inter-controller communication by COM port 2 is used to send or receive information among controllers. At start-up, the learning function monitors and evaluates a heat-up balance among channels. Then it calculates ramp-up-rate for each channel to make all heaters follow the temperature-rise-curve of a channel with the longest time to reach setpoint....

 Open the catalog to page 5
FB400 / FB900-6

Easy-setup and Data Monitoring via a standard data port 1 Communicate with a PC via USB port The FB Series has the loader port (provided as standard) to connect to a PC USB port. The standard port allows setup and data logging to be managed by the PC. The FB Series is recognized as an external device on the PC. USB communication converter COM-KG COM-KG-1N (With loader communication cable) COM-KG-NN (Without loader communication cable) No power supply cable necessary at setup Loader port (Provided as standard) RS-422A/RS-485 Loader Communication Loader communication cable Length : 1.5m Length...

 Open the catalog to page 6
FB400 / FB900-7

Inter-controller communication Inter-controller Communication The FB Series has a second communication port (COM2) for inter-controller communication. It achieves more precise cascade control and ratio control by sending data via digital communication while conventional cascade controllers send data to slave controllers by analog signal with less resolution. Auto-temperature-rise with Learning Function • Up to 32 controllers with 16 groups can be configured. • Auto-temperature-rise function is not available with Heat/Cool PID control tyoe. Temperature Ratio Setting • Up to 32 controllers with...

 Open the catalog to page 7
FB400 / FB900-8

Input • Universal input a) Temperature, Current, Low voltage input group Thermocouple : K, J, E, T, R, S, B, N (JIS/IEC) Low voltage (Input impedance : More than 1MQ) 0 to 1V DC, 0 to 100mV, 0 to 10mV DC -100 to + 100mV DC, -10 to + 10mV DC Current (Input impedance : 50Q) b) High voltage input group High voltage (Input impedance : 1MQ) -1 to +1V DC, 0 to 5V DC, 1 to 5V DC, 0 to 10V DC _(Use dip switch to change input group.)_ • When the sampling time is set to 0.1 sec or 0.05 sec, the following input ranges cannot be used: Influence of external 0.2mV/Q (Thermocouple input) Influence of lead 0.01%...

 Open the catalog to page 8
FB400 / FB900-9

^Digital Input (DI) (DI 1 to 4 : Optional, DI 5 to 7 : Standard) Number of inputs Up to 7 points (DI 1 to 4, DI 5 to 7)_ Input method Non-voltage contact input_ Function DI 1 to 4 : Memory area selection + Area set DI 5 to 7 : RUN/STOP, Remote/Local, Auto/Manual Alarm interlock reset, ^Remote Setpoint Input j (standard) Input a) Low voltage, current group 0 to 1V DC, 0 to 100mV DC, 0 to 10mV DC 4 to 20mA DC, 0 to 20mA DC b) High voltage group Sampling time 0.1 sec (with measuring input sampling time of 0.05 sec) 0.2 sec (with measuring input sampling time of 0.1 sec) 0.5 sec (with measuring input...

 Open the catalog to page 9
FB400 / FB900-10

: Required • : Selectable

 Open the catalog to page 10
FB400 / FB900-11

Quick start code 2 tells the factory to ship with each parameter preset to the values detailed as specified by the customer. Quick start code is not necessarily specified when ordering, unless the preset is requested.These parameters are software selectable items and can be re-programmed in the field via the manual. Specifications * Please specify "8" when the remote setpoint input signal is not used. Event Type Code Table Output 1 (OUT 1) (Output Allocation Table • Energized/De-energized is configurable except for the FAIL output. (Factory default setting: Energized) • Invalid for a non-existing...

 Open the catalog to page 11
FB400 / FB900-12

25 (Panel thickness must be between 1 to 10mm) (Panel thickness must be between 1 to 10mm) ^5Rear Terminals <Close horizontal mounting> * Up to 6 units Bteiltr’iiLT FB900 FB400 L n : Number of controllers (2=<n=<6) • Waterproof/dustproof is not available for close horizontal mounting. (*) Optional CT : Current transformer for heater break alarm PFF : Power feed forward transformer (RIKA KOGYO CO.,LTD) HEAD OFFICE : 16-6, KUGAHARA 5 CHOME OHTA-KU TOKYO 146-8515 JAPAN PHONE : 03-3751-9799 ( +81 3 3751 9799 ) Email : [email protected]

 Open the catalog to page 12

All RKC INSTRUMENT INC catalogs and technical brochures

  1. VGR-B100

    8  Pages

  2. PF900

    8  Pages

  3. MA901

    6  Pages

  4. MA900

    6  Pages

  5. COM-ME-1

    2  Pages

  6. SRX

    8  Pages

  7. SRZ

    12  Pages

  8. SB1

    8  Pages

  9. REX-F9000

    3  Pages

  10. HA930

    6  Pages

  11. GZ400 / GZ900

    12  Pages

  12. FB100

    8  Pages

  13. SA200

    6  Pages

  14. SA100

    6  Pages

  15. RZ SERIES

    4  Pages

  16. SB1 Series

    8  Pages

  17. RB SERIES

    8  Pages

  18. AG500

    108  Pages

  19. PRODUCT CATALOG

    167  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.