Ringbalance RW65
1 /2Pages

Ringbalance RW65

Ringbalance RW65
1 /2Pages

Catalog excerpts

Ringbalance RW65-1

Ringbalance RW65 measuring draft, pressure, differential pressure, and flow; optional: with contacts Measuring Ranges from 0...40 Pa to 0...1.8 kPa (0.15" W.C.-7" W.C.) - see next page - Scale Units Pa, kPa, daPa, mbar, mmWS, mmCE, in.W.C. Ambient temp. Setpoint adjustment (contacts) wall mounting IP65 (see next page) Option: Inductive Contacts Inductive sensors according to NAMUR / ATEX [EEx ia IIC T6], Turck or Pepperl & Fuchs, type "N" ("SN" also available) 1xMin Type IK1/0 1xMax Type IK0/1 2xMin Type IK2/0 1xMin / 1xMax Type IK1/1 "Min"- function: vane dips into slot at decreasing pressure "Max"-function: vane dips into slot at increasing pressure RW65 with 2 Inductive Contacts Isolation Switch Amplifier (Turck) housing for snap-in on DIN-rail, 18mm wide, universal power supply IM1-121Ex-R single-channel, for 1 Inductive sensor IM1-22Ex-R dual channel, for 2 Inductive sensors Option: Mechanical Contacts Applicable for ranges above 200 Pa, only Contacts rated at 30W / 50VA; max. 250V. Hysteresis 1-2% 1x Min MK1/0 contact closing at decreasing pressure 1x Max MK0/1 contact closing at increasing pressure Min / Min MK2/0 both closing at decreasing pressure Max / Max MK0/2 both closing at increasing pressure Min / Max MK1/1 1x opens 1x closes Type Order Specifications Metal vane Ringbody Max-Sensor Inductive Sensors 1. Type: RW65 2. Measuring range 3. Options (IK... MK...) RW65 - (-25/0/+25 Pa) - IK1/1 Isolation Switching Amplifier IM1-22-Ex-R

 Open the catalog to page 1
Ringbalance RW65-2

Measuring Ranges, Filling Fluids Overload Limits Filling Fluids Note: All Ringbalance instruments are factory-filled. The type of oil need not be mentioned in the order. "Mineral Oil" density 0,8 kg/l; for ranges up to +/-700 Pa max. overload: +/-900 Pa Overload Protection Every Ringbalance is inherently protected to at least +/-900 Pa (3.5"W.C.), even it has, for example, a measuring range of only 0-40 Pa (0.15"W.C.). With the synthetic oil filling fluid, the Ringbalance is inherently protected to +/-2.1 kPa (8"W.C.). If those limits (900 Pa / 2.1 kPa) are expected to be exceeded in the specific...

 Open the catalog to page 2

All Rixen Messtechnik catalogs and technical brochures

  1. RIXOTACT_4

    2  Pages

  2. MU-Analog-65

    2  Pages

  3. MU Digital

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.