Rittal - The System. Faster - better - everywhere. Q Roof-mounted Blue e+ cooling unit Integration solution VX25
Open the catalog to page 1Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ ◾ Cooling unit with 1.3 kW and Blue e+ technology with the dimensions W x H x D 800 x 2200 x 600 mm – integrated into the VX25 baying enclosure system ◾ No assembly outlay – the cooling unit, door limit switch and connection cabling are installed ready-to-connect ◾ State-of-the-art design – not a cooling unit built onto the enclosure Excellent planning certainty ◾ The digital twin is available in the EPLAN Data Portal ◾ Dependable and efficient construction planning with EPLAN Pro Panel ◾ “Thermal Design...
Open the catalog to page 2HIGH EFFICIENCY – THE BLUE E+ PRINCIPLE Benefit from this revolutionary energy efficiency with innovative hybrid technology. Blue e+ integration solution
Open the catalog to page 3Accessories for climate control Cat. 35, page 454 RiDiag software Cat. 35, page 474 Roof-mounted Blue e+ cooling unit Page 5 Supply includes: Approvals: - Basic enclosure VX25, door, - UL + cUL - NITW roof, rear panel, side panels, gland plates, mounting plate - Lock: 3 mm double-bit - Integral door-operated switch - Integral Blue e+ cooling unit 1.5 kW - Electric condensate evaporator - Pleated filter Benefits: - The perfect symbiosis of the VX25 baying enclosure system and Blue e+ cooling unit - The cooling unit is easily pulled out forwards for maintenance purposes - No assembly work...
Open the catalog to page 4Accessories for climate control Cat. 35, page 454 Therm software Cat. 35, page 474 RiDiag software Cat. 35, page 474 Approvals: - UL + cUL - FTTA - UR + cUR - ACVS2/8 - Tested safety GS Benefits: - Average 75% energy savings thanks to speed-regulated components and heat pipe technology - Suitable for international use due to a unique multi-voltage capability - Longer service life of the components inside the enclosure and the cooling unit due to component-friendly cooling - Intuitive operation due to touch display and intelligent interfaces Temperature control: - e+ controller (factory...
Open the catalog to page 5Display frame for Blue e+ roof-mounted cooling unit and VX25 Blue e+ integration solution The display frame allows the touch display of the roof-mounted cooling unit Blue e+ or the VX25 Blue e+ integration solution to be positioned in the enclosure door. Benefits: - For positioning the display at the optimum operator height Material: - Plastic Colour: - RAL 7016 Protection category IP to IEC 60 529: - IP 54 Supply includes: - Display frame - Blanking cover - Assembly parts and sealing material Pleated filter for Blue e+ roof-mounted cooling unit and VX25 Blue e+ integration solution To...
Open the catalog to page 7Accessories Electrical condensate evaporation for Blue e+ roof-mounted cooling units Tool-free mounting of the condensate evaporator on the underside of the roof-mounted Blue e+ so that it is not visible from the outside. Any condensation is evaporated and emitted to the ambient air via the air exhaust of the cooling unit. Material: - Plastic Colour: - RAL 9005 Supply includes: - Electrical condensate evaporation - Shipping brace screw - Entry grommet Blue e+ integration solution
Open the catalog to page 8Technical details VX25 Blue e+ integration solution 54.8 Roof-mounted Blue e+ cooling unit Mounting cut-out 70 Blue e+ integration solution Note: Only suitable for mounting on enclosures with minimum dimensions 800 x 600 (W x D).
Open the catalog to page 9Enclosure internal temperature - T = 45°C - T = 40°C - T = 35°C - Ti = 30°C - T = 25°C Pc = Total cooling output [W] Tu = Ambient temperature [°C] Blue e+ integration solution
Open the catalog to page 10Technical details Air routing External circuit Maximum flexibility ◾ The ambient air is drawn in and expelled at the front of the cooling unit. ◾ This means there is no need to observe any minimum distances from adjacent devices or walls. Flexible baying – no minimum distances to the left or right required Flexible installation location – no minimum distances at the top or rear required Internal circuit Optimum air circulation ◾ The cooled air is expelled in the front section of the enclosure ◾ In this way, the cold air flows around and cools other components such as frequency converters
Open the catalog to page 11■ Enclosures ■ Power Distribution ■ Climate Control ■ IT Infrastructure ■ Software & Services You can find the contact details of all Rittal companies throughout the world here. POWER DISTRIBUTION CLIMATE CONTROL SOFTWARE & SERVICES^"
Open the catalog to page 12All RITTAL catalogs and technical brochures
-
VX25
220 Pages
-
Rittal After Sales Service
20 Pages
-
Optimise wire processing
8 Pages
-
Rittal Automation Systems
76 Pages
-
TS 8 Lock systems
3 Pages
-
Network enclosures TE 8000
28 Pages
-
Efficient Liquid Cooling
44 Pages
-
Rittal International Service
12 Pages
Archived catalogs
-
Security rooms for data centres
16 Pages
-
TS IT RACK
68 Pages
-
TS IT technik im Detail
6 Pages
-
TS IT Umstellhife
16 Pages
-
Support arm system CP 60/120/180
12 Pages
-
Terminal boxes HD
2 Pages
-
System consulting
12 Pages
-
RiMatrix S-Make IT easy
32 Pages
-
IT infrastructures
78 Pages
-
Connector gland
4 Pages
-
Industry solutions
68 Pages
-
IT Catalogue 2007
476 Pages
-
Energy efficiency by design
8 Pages
-
RiLine60
120 Pages
-
Ri4Power
148 Pages
-
TopTherm chiller
6 Pages
-
TopTherm fan-and-filter unit
8 Pages
-
Connector gland
4 Pages
-
Monitor/keyboard unit
2 Pages
-
Hygienic Design
20 Pages
-
Catalogue 32
1348 Pages