PA series

PA series

PA series

Product catalog summary
Overview: The document discusses the application and features of RINGSPANN Force Limiters, which are used to prevent damage in machinery by limiting excessive forces. These devices are crucial in installations where longitudinal forces are transmitted, ensuring safety and operational efficiency.
Application Example: Illustrated in figure 74-2, the Force Limiter is integrated into the connecting rod of feeding equipment. It prevents damage by disengaging when force exceeds a preset limit, signaling the drive to switch off via a non-contact proximity switch.
Features:
  • Limits forces in both directions
  • High response accuracy
  • Automatic re-engagement
  • Maintenance-free and robust construction
  • Simple design and easy installation
  • Handles disengaging forces up to 140,000 N
  • Adjustable disengaging force
Technical Specifications: The Force Limiter's assembly and operation are detailed with figures 76-1 and 76-4. It includes components like locking segments, disc spring pack, and a slide ring. The disengaging force (FA) is adjustable, and the maximum operating force (FB) should be less than FA but more than FC (0.2 x FA).
Technical Data and Dimensions: The document provides a table with technical data for different models (PA 12 to PA 75), including dimensions and force capacities. Accessories like a proximity switch are available, which signals excessive force for drive unit braking.
Ordering Information: Customers should specify the required disengaging force when ordering. The Force Limiter can be supplied with a preset disengaging force, and custom rod lengths and connections are available.
See more

Catalog excerpts

PA series-1

Features • Forces limited in both directions • High response accuracy • Automatic re-engagement • Maintenance-free • Robust construction • Uncomplex design • Easy to build on • For disengaging forces up to 140 000 N • Disengaging force finely adjustable Application Example Shown in figure 74-2 is the operation of the feeding equipment for workpieces on an interlinked installation. The feeding equipment is driven by a crankshaft pin on the output shaft via a connecting rod and a lever. The Force Limiter with non-contact proximity switch is built into the connecting rod as shown in figure 74-2. If the material jams the force in the connecting rod increases considerably, causing extensive damage in the machine if there is no safety installation available. The Force Limiter ensures that no excessive high forces reach the feed mechanism. If the force in the Force Limiter exceeds its preset limit it disengages and, through the non-contact proximity switch, a signal is given to switch off the drive. Why RINGSPANN Force Limiters? There are many ways of transmitting forces and torques in machines, installations and vehicles. The advances in constructional engineering are marked by components which run faster and are of a lighter construction. Therefore it has become necessary to provide for safety elements at the critical points. Until now these were usually in the shape of overload clutches on rotating shafts which, once the maximum torque was exceeded, would either slip, stop, or automatically cut out. However, many machines and installations have elements which transmit longitudinal forces. To prevent damage and breakdowns a solution for limiting the amount of these forces has to be found. RlNGSPANN has designed a series of Force Limiters, outstanding in that forces up to a certain size can be transmitted in both directions completely free of play and rigid. On exceeding the pre-set disengaging force FA the power of the force is interrupted and the output part is no longer driven. After the overload has been cleared the driving part and the driven part are aligned towards each other and the Force Limiter re-engages automatically. The Force Limiter can be fitted with non-contact proximity switch to give early warning of reaching a certain force, or di

 Open the catalog to page 1
PA series-2

RINGSPANN Force Limiter PAG as overload clutch in a filling plant

 Open the catalog to page 2
PA series-3

Assembly and Operation Assembly and operation of the RINGSPANN Force Limiter can be seen in illustrations 76-1 and 76-4. The sectional drawing in figure 76-1 shows the standard type of basic unit. The rod (1) is connected with the housing (3) via locking segments (2). The locking segments (2) are pressed into the groove (5) of the rod and against the conical surface (6) of the slide ring via the disc spring pack (4). If a force is effective between the rod and the housing, then, according to figure 76-4, up to force FB no movement takes place between the two parts. If the force is increased the...

 Open the catalog to page 3
PA series-4

Series PAG with mounted proximity switch K proximity switch in push direction disengaged in pull direction disengaged Series PA without proximity switch 77-1 Technical Data and Dimensions Type without with proximity proximity switch switch PA 12 PA 20 PA 30 PA 50 PA 75 Proximity switch • Proximity switch: signals excessive disengaging force for drive unit braking Operating voltage: Engagement travel Across flats Normal condition: Domestic electricity requirement: Protection class: Ambient temperature: Cable length: Please indicate the required disengaging force on your order. The Force Limiter...

 Open the catalog to page 4

All RINGSPANN catalogs and technical brochures

  1. FB Series EN

    2  Pages

  2. DH 010 FPM

    1  Page

  3. HR 130 FHK

    2  Pages

  4. Datasheet SFB

    2  Pages

  5. Datasheet E

    2  Pages

  6. Datasheet FHD

    4  Pages

  7. Datasheet FH

    4  Pages

  8. Beam Couplings

    26  Pages

  9. MV 033 FEM

    8  Pages

  10. DV 020 FHM

    1  Page

  11. DH 020 FHM

    1  Page

  12. DV 030 FHM

    1  Page

  13. DH 030 FHM

    1  Page

  14. DV 030 FHA

    1  Page

  15. DH 030 FHA

    1  Page

  16. DU 060 FHM

    2  Pages

  17. DH 020 FKM

    1  Page

  18. DH 005 PFK

    1  Page

  19. DV 020 FKM

    1  Page

  20. DH 010 PFK

    1  Page

  21. DH 015 PFK

    1  Page

  22. DH 020 PFK

    1  Page

  23. DV 030 PFM

    2  Pages

  24. DH 030 PFM

    2  Pages

  25. DV 035 PFM

    2  Pages

  26. DH 035 PFM

    2  Pages

  27. DU 060 PFM

    2  Pages

  28. DH 010 MSM

    1  Page

  29. DV 020 MSM

    1  Page

  30. DH 020 MSM

    1  Page

  31. DV 020 MKM

    1  Page

  32. DH 020 MKM

    1  Page

  33. HW 075 FHM

    2  Pages

  34. HS 075 HFK

    2  Pages

  35. DV 020 FEM

    1  Page

  36. DV 020 PFK

    1  Page

  37. BCS 600

    4  Pages

  38. DS

    2  Pages

  39. DU 060 FPM

    2  Pages

  40. HW 075 HFK

    2  Pages

  41. HS 120 HFK

    2  Pages

  42. RLK 603 S

    4  Pages

  43. RLK 603 K

    3  Pages

  44. HW 100 HFA

    2  Pages

  45. FN series

    2  Pages

  46. DT

    2  Pages

  47. HW 063 HFA

    1  Page

  48. FD series

    2  Pages

  49. Trantorque OE

    2  Pages

  50. SIKUMAT® SC

    6  Pages

  51. SIKUMAT® SG

    6  Pages

  52. SIKUMAT® ST

    6  Pages

  53. SIKUMAT® SN

    6  Pages

  54. SIKUMAT® SA

    6  Pages

  55. SIKUMAT® SU

    6  Pages

  56. SIKUMAT® SR

    6  Pages

  57. SIKUMAT® SB

    6  Pages

  58. SIKUMAT® SL

    6  Pages

  59. RIMOSTAT® RS

    4  Pages

  60. RSHD series

    2  Pages

  61. RT

    2  Pages

  62. HDDS series

    2  Pages

  63. LAFF series

    2  Pages

  64. BKFF series

    2  Pages

  65. HKFF series

    2  Pages

  66. KFFF series

    2  Pages

  67. LBDF series

    2  Pages

  68. BKDF series

    2  Pages

  69. HKDF series

    2  Pages

  70. KFDF series

    2  Pages

  71. BKDI series

    2  Pages

  72. SKDZ series

    2  Pages

  73. FZ … series

    6  Pages

  74. DH 030 FPA

    2  Pages

  75. DV 030 FPA

    2  Pages

  76. DH 030 FPM

    2  Pages

  77. DV 030 FPM

    2  Pages

  78. DH 020 FPM

    1  Page

  79. DH 012 FEM

    1  Page

  80. IR series

    2  Pages

  81. FNR series

    2  Pages

  82. FSN series

    2  Pages

  83. FRHN

    2  Pages

  84. FDN series

    2  Pages

  85. FXN series

    4  Pages

  86. FRHD series

    2  Pages

  87. FBL series

    2  Pages

  88. FBE series

    2  Pages

  89. FAV series

    2  Pages

  90. FA series

    2  Pages

  91. BC series

    2  Pages

  92. BA series

    2  Pages

  93. BM series

    2  Pages

  94. FBF series

    2  Pages

  95. FR series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.