1. Catalogs
  2. RIGCHINA GROUP COMPANY
  3. RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids

RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids

RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids

RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids

Product catalog summary
Summary: The Electrical Stability Tester is designed to measure the stability of water-in-oil emulsions and evaluate oil-based drilling fluids. It is applicable in various industries such as petroleum and metallurgy.

Main Technical Parameters:
  • Power Supply: AC220V±5%, 50Hz
  • Output Voltage: 0~2000V, 340Hz
  • Electrode Distance: 1.59mm
  • Power: 750W

Structure and Working Principles: The instrument consists of a measuring device, electrodes, power lead, sample cup, and lid. It uses frequency conversion technology to alter voltage and measure electrical stability.

Operations:
  1. Ensure correct voltage and ground protection.
  2. Prepare and heat the sample.
  3. Insert electrodes and start the device.
  4. Adjust voltage until the alarm sounds, indicating the stability value.
  5. Record the value and reset the device.

Maintenance: Keep the instrument dry, handle with care, and ensure proper grounding. Clean and store in a dry environment after use.

Transportation and Storage: Follow JB/T9329-1999 standards, store in ventilated areas free from corrosive impurities.

Fault Diagnosis and Removal: Common issues include alarm malfunctions, abnormal regulator noise, and data deviations. Solutions involve replacing components or adjusting settings.

Accessories and Components: Includes electrodes, sample cup, cup lid, and power lead. Technical documents provided include operation instructions and a certificate of approval.
See more

Catalog excerpts

RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-1

DRILLNG FLUID TESTING INSTRUMENT ELECTRICAL STABILITY TESTER Instruction Manual (Zhejiang, CHINA)

 Open the catalog to page 1
RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-2

DRILLNG FLUID TESTING INSTRUMENT 1. Summary The Electrical Stability Tester is a kind of instrument used mainly to measure the relative stability of water in oil (w/o) emulsion.In addition, the electrical resistance caused by impurity present in electrolytic solution and the stability to time can be predicted from the measurements of the relative emulsion stability. This instrument also can be used to evaluate the oil base drilling fluids, oil base releasing stuck agent, cement and crack water etc. Therefore, it can be extensively applied in petroleum, metallurgy, drilling crew and research institutions...

 Open the catalog to page 2
RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-3

DRILLNG FLUID TESTING INSTRUMENT 1. Switch of power supply; (2) Working principles The instrument adopts the advanced technology of frequency conversion. It alters the AC220V±5%, 50Hz to AC220V, 340Hz. The voltage output of 0~2000V, 340Hz can be realized by virtue of regulating using the 340Hz voltage regulator and increasing voltage using the transformer of intermediate frequency. When regulating voltage, the material tested between electrodes is ionized slowly and finally broken down. At this time, the feedback loop is working and the instrument starts alarming. The instrument is replaced the...

 Open the catalog to page 3
RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-4

DRILLNG FLUID TESTING INSTRUMENT Prevent the transformer of high voltage is burnt out due to short-circuit current. (9) After the tests are completed, press the key of “STOP” on the frequency meter. The displayed “340.0” will stop altering about three seconds later. At this time, turn off the main switch and then take off the plug of power supply (10) Take off the electrode, and then wash and dry disposal for the use next time. 6. The maintenance of the instrument (1) The environment of usage for the instrument should be kept dry and neat. (2) The operator should be familiar with all the operation...

 Open the catalog to page 4
RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-5

DRILLNG FLUID TESTING INSTRUMENT 8. Fault judge and remove Item Removing method ① The controllable silicon on line board alarms continuously when resetting the increment knob tighten the linking line ①The carbon brush of voltage regulator of is ①Replace carbon brush worn seriously. ②Dry the voltage regulator Have abnormal voice from regulator during regulating until operation normally regulator is made moist ① The resistance value ①Adjust the potentiometer of potentiometer on line ② polish the electrode surface deviated seriously for each time board changes. ② The gently with thin emery cloth....

 Open the catalog to page 5
RIGCHINA-Electrical Stability tester |Model ETC | Recommended Practice Standard Procedure for Field Testing Oil-Based Drilling Fluids-6

DRILLNG FLUID TESTING INSTRUMENT 9. A list for accessories, tools, major components and technical documents Power lead (2) Major components Item Model number Position used Measuring package Operation instruction Container load plan EMAIL: [email protected] NO.80ADD: NO.80-82, QIUDE RD, WEST CHENG INDUSTRIAL ESTATE, YONGKANG, ZHEJIANG, CHINA

 Open the catalog to page 6

All RIGCHINA GROUP COMPANY catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.