RECTANGULAR INNER PROFILE MEASUREMENT SYSTEM RF096-170x110 Series User's manual www.riftek.com [email protected]
Open the catalog to page 1Rectangular Inner Profile Measurement System. RF096-170x110 Series
Open the catalog to page 2Rectangular Inner Profile Measurement System. RF096-170x110 Series Safety precautions · · · · Use supply voltage and interfaces indicated in the system specifications. In connection/disconnection of cables, the system power must be switched off. Do not use the system in locations close to powerful light sources. The system must be grounded. The system has been developed for use in industry and meets the requirements of the following Directives: · EU directive 2014/30/EU. Electromagnetic compatibility (EMC). · EU directive 2011/65/EU, “RoHS“ category 9. Laser safety The system makes use of a c.w....
Open the catalog to page 3Rectangular Inner Profile Measurement System. RF096-170x110 Series Basic technical data Parameter Base distance/measurement range (#1 sensor), mm Base distance/measurement range (#2 sensor), mm Base distance/measurement range (#3 sensor), mm Profile measurement accuracy, mm Space resolution, points/turnover Light source Laser output power, mW Laser safety class Laser beam shape Output interface Power supply, V Power consumption, W Environmental resistance Vibration Shock Permissible ambient light, lx Relative humidity, % Operating ambient temperature, °С Storage temperature, °С Housing material...
Open the catalog to page 4Rectangular Inner Profile Measurement System. RF096-170x110 Series Example of item designation when ordering Description Profile length, mm Profile width, mm Example: RF096-170x110 – Rectangular Inner Profile Measurement System, measurement range: Length - 170 mm , Width - 110 mm. Structure and operating principle Operation of the system is based on the scanning of the hole inner surface by rotating triangulation laser sensors. The system contains the measurement head with three laser sensors inside, Figure 1. The measurement head is mounted on the rotation module. Radiation of semiconductor...
Open the catalog to page 5Rectangular Inner Profile Measurement System. RF096-170x110 Series Designation of connector contacts Wire color White-orange Note Transmit data Ethernet + TXRX+ RXPower+ Power+ PowerPower- Orange White-green Green Blue White-blue Brown White-brown Transmit data Ethernet Receive data Ethernet + Receive data Ethernet Power supply: 9...24 V Power consumption: 5 W (standby mode), 12 W (scan mode) Cable Designation of cable wires is given in the table below: Pin number RJ-45 RJ-45 RJ-45 RJ-45 free lead free lead free lead free lead Assignment #09 0426 10 08 TX+ TXRX+ RXAL (output) Power+ IN (input)...
Open the catalog to page 6Rectangular Inner Profile Measurement System. RF096-170x110 Series Network setting All systems are shipped with the following default network configuration: IP address of the system – 192.168.0.3. Configure the network card of your PC in the following address space: 192.168.0.Х. Connect the system directly to PC or through the network switch. Preparation for use Preparation of the system includes: · Visual inspection. · Installation and connection. · Adjustment. · Switching on the system. Visual inspection Before operating, it is needed to ensure of the serviceability of the equipment: · Check...
Open the catalog to page 7Rectangular Inner Profile Measurement System. RF096-170x110 Series Service software General information The service software is intended for: · Testing and demonstration of the work of the system. · Setting parameters. · Calibration. The service software includes: · SDK library. · RF096 Test Program. System requirements · Operating system Windows 7 and later. · Microsoft Visual C++ Runtime Redistributable for Windows 64-bit. Shipped with the package (you need to run vcredist_x64.exe). Description Dynamic link library. C header file. Refer to this file to understand the SDK functions. There is...
Open the catalog to page 8Rectangular Inner Profile Measurement System. RF096-170x110 Series When the connection is established, the system information will be displayed: To disconnect from the system, click Disconnect.
Open the catalog to page 9Rectangular Inner Profile Measurement System. RF096-170x110 Series Calibration ATTENTION! 1. It is imperative to perform the calibration procedure before the first use. 2. While using the system, you can repeat the calibration procedure in case of obtaining incorrect results. The calibration must be performed by using the calibration block supplied with the system. The calibration procedure: Step 1 2 3 Description Install the calibration block: the bottom side is the side with the axes designation, the axes designation must be to the left. Install the system inside the calibration block so that...
Open the catalog to page 10Rectangular Inner Profile Measurement System. RF096-170x110 Series CAPI Controle e Automaçã o Ltda Rua Itororó, 121, CEP 13466-240 Americana-SP, Brazil Tel: +55 19 36047068 Fax: +55 19 34681791 [email protected] www.capicontrole.com.br EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT República de Honduras 11936 Las Condes, Santiago de Chile Tel: +56 9 59200362 [email protected] www.molingenieria.com...
Open the catalog to page 11Rectangular Inner Profile Measurement System. RF096-170x110 Series BLET Measurement Group S.A.S. Disynet GmbH RAILWAY INSTRUMENTS ONLY Juvan teollisuuskatu 28 FI-02920 ESPOO, Finland Tel: +358 400 422 900 Fax: +358 9 2511 5510 [email protected] www.teraspyora.fi ALTHEN GmbH Meß- und Sensortechnik OPTICAL MICROMETERS ONLY Sapelloh 172, 31606 Warmsen, Germany Tel: +49 5767 96020 Fax: +49 5767 93004 [email protected] www.finger-kg.de EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected]...
Open the catalog to page 12Rectangular Inner Profile Measurement System. RF096-170x110 Series Althen Sensors & Controls BV BLConsult Ryssbält 294, 95 291 Kalix, Sweden EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl [email protected] www.blconsult.se PB 468, N-1327 Lysaker, Norway Tel: +47 23 891015 Fax: +47 92101005 [email protected] www.salitec.no Las Codornices 104, Surquillo, Lima, Peru Tel/fax: +51 992436734 [email protected] www.verne.cl EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT...