Multisensor Inner Diameter Measurement System Manual
1 / 13Pages

Catalog excerpts

Multisensor Inner Diameter Measurement System Manual - 1

MULTISENSOR INNER DIAMETER MEASUREMENT SYSTEM RF040-65/115 Series User's manual www.riftek.com info@riftek.com

Open the catalog to page 1
Multisensor Inner Diameter Measurement System Manual - 2

Multisensor Inner Diameter Measurement System. RF040-65/115 Series

Open the catalog to page 2
Multisensor Inner Diameter Measurement System Manual - 3

Multisensor Inner Diameter Measurement System. RF040-65/115 Series Safety precautions · · · · Use supply voltage and interfaces indicated in the system specifications. In connection/disconnection of cables, the system power must be switched off. Do not use the system in locations close to powerful light sources. The system must be grounded. The system has been developed for use in industry and meets the requirements of the following Directives: · EU directive 2014/30/EU. Electromagnetic compatibility (EMC). · EU directive 2011/65/EU, “RoHS“ category 9. Laser safety The sensors make use of...

Open the catalog to page 3
Multisensor Inner Diameter Measurement System Manual - 4

Multisensor Inner Diameter Measurement System. RF040-65/115 Series Basic technical data Parameter Diameter measurement range, mm Measurement accuracy, um Light source Output power, mW Laser safety class Output interface Power supply, V Power consumption, W Environmental resistance Enclosure rating Vibration Shock Permissible ambient light, lx Relative humidity, % Operating ambient temperature, ° С Storage temperature, °С Value 65...115 ±25 red semiconductor laser, 660 nm wavelength <1 2 (IEC60825-1) Ethernet 9…36 7 IP67 20 g / 10…1000 Hz, 6 hours for each of XYZ axes 30 g / 6 ms 30000 5-95...

Open the catalog to page 4
Multisensor Inner Diameter Measurement System Manual - 5

Multisensor Inner Diameter Measurement System. RF040-65/115 Series The system operates as follows. The measurement system is inserted into the pipe and moved by translation module to the definite position. Laser sensors measure distances to the inner surface. Software calculates inner diameter of the pipe. Overall and mounting dimensions are shown in Figure 2. 5 Figure 2. Overall and mounting dimensions Overall demands for mounting The system is positioned so that the object under control has to be placed within the working range of the system. ATTENTION! The system must be grounded –...

Open the catalog to page 5
Multisensor Inner Diameter Measurement System Manual - 6

Multisensor Inner Diameter Measurement System. RF040-65/115 Series Wire color Power supply: 9…36 V Power consumption: 7 W White Green Yellow Gray Pink Blue Ethernet cable Wire color White-orange Orange White-green Green Transmit data Ethernet + Transmit data Ethernet Receive data Ethernet + Receive data Ethernet - Network setting All systems are shipped with the following default network configuration: IP address of the system – 192.168.0.3. Configure your PC's network card in the following address space: 192.168.0.Х. Connect system directly to PC or through network switch. Preparation for...

Open the catalog to page 6
Multisensor Inner Diameter Measurement System Manual - 7

Multisensor Inner Diameter Measurement System. RF040-65/115 Series Visual inspection · Check the system for completeness and absence of damage. · Check the cables and ground wire. · Check the condition of output windows and, if necessary, wipe them with a soft Installation and connection · Install the system on a robot or linear translation module (NOTE: as an option, the system can be fixed and the robot sets the object in control position). · Make electrical connections (see Par. 9). Switching the system Feed power to the system – 9…36 V. Calibrate the system according to Par. 12.4.2. The...

Open the catalog to page 7
Multisensor Inner Diameter Measurement System Manual - 8

Multisensor Inner Diameter Measurement System. RF040-65/115 Series SDK usage scenario: Step 1 Description Call connect() to connect to the system. Call switchSensor(true) to switch on the system. Call calibrate() to run the calibration, or getCalibratedMeasures() to get calibration data. Call getMeasures(result_array) to run the measurement process. Call switchSensor(off) to switch off the system - optional. Call disconnect() to disconnect from the system - optional, called from destructor. When you start the program, it searches for devices connected. If the network settings of your PC are...

Open the catalog to page 8
Multisensor Inner Diameter Measurement System Manual - 9

Multisensor Inner Diameter Measurement System. RF040-65/115 Series When the system is calibrated, you can start the measurement process. Press the Enter key in order to perform the measurement. The program will show the calculated values: Warranty policy Warranty assurance for the Multisensor Inner Diameter Measurement System RF040-65/115 Series – 24 months from the date of putting in operation; warranty shelflife – 12 months. Revision 1.0.0 Starting document. Applied Measurement Australia Pty Ltd Althen Sensors & Controls BV RAILWAY INSTRUMENTS ONLY Thornton Plaza, Unit 5, 27 Thornton...

Open the catalog to page 9
Multisensor Inner Diameter Measurement System Manual - 10

Multisensor Inner Diameter Measurement System. RF040-65/115 Series Beijing Haiwei Lutong Technology Co., Ltd Chongqing Wolf Industrial Technology Co., Ltd Yard 1, Tianxing Street, Fangshan District, Beijing, China Tel: +86 10 8366 1866 Fax: +86 10 8366 1866 info@haiwlt.com www.haiwlt.com Room 2307 / 2308, Light of City international business building, No. 19 Jiangnan Avenue, Nan'an District, Chongqing, China Tel: 023 62832618 Fax: 023 62832113 info@wolf-hk.com www.wolf-hk.com Beijing Gemston Mechanical & Electrical Equipment Co., Ltd Xi'an Win-Success Automation Technology Co.,Ltd RAILWAY...

Open the catalog to page 10
Multisensor Inner Diameter Measurement System Manual - 11

Multisensor Inner Diameter Measurement System. RF040-65/115 Series ALTHEN GmbH Meß- und Sensortechnik OPTICAL MICROMETERS ONLY Sapelloh 172, 31606 Warmsen, Germany Tel: +49 5767 96020 Fax: +49 5767 93004 finger@finger-kg.de www.finger-kg.de EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 biuro@ascorail.pl export@ascorail.pl www.ascorail.pl Influx Big Data Solutions Pvt Ltd Paragon Instrumentation Engineers Pvt. Ltd. PT. DHAYA BASWARA SANIYASA No:2, Krishvi, Ground Floor, Old Airport Road, Domlur,...

Open the catalog to page 11
Multisensor Inner Diameter Measurement System Manual - 12

Multisensor Inner Diameter Measurement System. RF040-65/115 Series PB 468, N-1327 Lysaker, Norway Tel: +47 23 891015 Fax: +47 92101005 mail@salitec.no www.salitec.no Las Codornices 104, Surquillo, Lima, Peru Tel/fax: +51 992436734 info@verne.cl www.verne.cl EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 biuro@ascorail.pl export@ascorail.pl www.ascorail.pl Campal Inovacoes Ferroviarias Lda. ul. Domaniewska 17/19, 02-672 Warsaw, Poland info@riftek.com www.riftek.com Lagoas Park, Edifício 7, 1° Piso Sul,...

Open the catalog to page 12