Catalog excerpts

Laminated Tubes Geometry Measurement System Manual-1

LAMINATED TUBES GEOMETRY MEASUREMENT SYSTEM RF092-13/50 Series User's manual www.riftek.com [email protected]

 Open the catalog to page 1
Laminated Tubes Geometry Measurement System Manual-2

Laminated Tubes Geometry Measurement System. RF092-13/50 Series

 Open the catalog to page 2
Laminated Tubes Geometry Measurement System Manual-3

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Safety precautions · · · · Use supply voltage and interfaces indicated in the system specifications. In connection/disconnection of cables, the system power must be switched off. Do not use the system in locations close to powerful light sources. The system must be grounded. The system has been developed for use in industry and meets the requirements of the following Directives: · EU directive 2014/30/EU. Electromagnetic compatibility (EMC). · EU directive 2011/65/EU, “RoHS“ category 9. Laser safety The sensors make use of a c.w....

 Open the catalog to page 3
Laminated Tubes Geometry Measurement System Manual-4

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Basic technical data Parameter Diameter measurement range Diameter measurement accuracy Foil thickness range Foil and weld thickness measurement accuracy Tube length measurement accuracy Light source Output power Laser safety class Output interface Power supply Power consumption Environmental resistance Vibration Shock Permissible ambient light Relative humidity Operating ambient temperature Storage temperature Housing material Weight (without cable) Value 13...50 mm ±10 µm 0,05…0,5 mm ±5 µm ±0,1 mm red semiconductor laser, 660 nm...

 Open the catalog to page 4
Laminated Tubes Geometry Measurement System Manual-5

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Structure and operational principle The system structure is shown in Figure 1: Figure 1. The system structure Linear translation stage 1 with stepper motor 2 carries rotation module 3 with inbuilt motor and encoder (not shown). Multi-position linear translation module 4 with motor 5 is placed on the rotation module. Module 4 carries three triangulation laser sensors 6-8. Laser sensor 8 is intended for scanning of tube inner surface, laser sensors 6 and 7 are intended for scanning of tube outer surface. Measurement lines of sensors...

 Open the catalog to page 5
Laminated Tubes Geometry Measurement System Manual-6

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Overall and mounting dimensions are shown in Figure 2. Figure 2. Overall and mounting dimensions Connection Ethernet cable

 Open the catalog to page 6
Laminated Tubes Geometry Measurement System Manual-7

Laminated Tubes Geometry Measurement System. RF092-13/50 Series B4B-ZR BINDER 09 0426 10 08 LAPP CABLE ETHERLINE FD P BK CAT.5e Wire color White-orange Note Transmit data Ethernet + TXRX+ RXPower+ Power+ PowerPower- Orange White-green Green Blue White-blue Brown White-brown Transmit data Ethernet Receive data Ethernet + Receive data Ethernet Power supply: 24 V DC Power consumption: <30 W Cable for motor and limit switch Network setting All systems are shipped with the following default network configuration: IP address of the system – 192.168.0.3. Configure your PC's network card in the following...

 Open the catalog to page 7
Laminated Tubes Geometry Measurement System Manual-8

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Preparation for use The preparation involves the following steps:  Visual inspection.  Installation and connection. · Switching the system. · Calibration. Visual inspection · Check the system for completeness and absence of damage. · Check the cables and ground wire. · Check the condition of output windows and, if necessary, wipe them with a soft Installation and connection · Install the system. · Make electrical connections (see Par. 8). Switching the system Feed power to the system – 24 V DC. The calibration procedure must be...

 Open the catalog to page 8
Laminated Tubes Geometry Measurement System Manual-9

Laminated Tubes Geometry Measurement System. RF092-13/50 Series SDK library Class name: rf096112. Description of class members: Setup(remote_ip, remote_port, local_port, local_port) Set network parameters. Must be called before connecting to the device. Returns: void. Normal parameters: b"192.168.0.3", 6008, 6004 (customizable). Connect() Try to connect and read the device parameters stored in flash. Returns: boolean; "True" on success. Disconnect() Close connection sockets. Returns: void. Calibrate(sampleName) Run the calibration procedure. sampleName: a name of calibration sample. Calibration...

 Open the catalog to page 9
Laminated Tubes Geometry Measurement System Manual-10

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Applied Measurement Australia Pty Ltd Althen Sensors & Controls BV RAILWAY INSTRUMENTS ONLY Thornton Plaza, Unit 5, 27 Thornton Crescent, Mitcham VIC 3132, Australia Tel: +61 39874 5777 Fax: +61 39874 5888 [email protected] www.appliedmeasurement.com.au BOSNIA AND HERZEGOVINA ASCO RAIL sp. z o.o. EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl CAPI Controle e Automaçã o Ltda...

 Open the catalog to page 10
Laminated Tubes Geometry Measurement System Manual-11

Laminated Tubes Geometry Measurement System. RF092-13/50 Series CZECH REPUBLIC Rm 2205-2210, Zhongyou Hotel 1110 Nanshan Road, Nanshan District 518054 Shenzhen, China Tel: +86 755-26528100/8011/8012 Fax: +86 755-26528210/26435640 [email protected] www.51sensors.com EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected]...

 Open the catalog to page 11
Laminated Tubes Geometry Measurement System Manual-12

Laminated Tubes Geometry Measurement System. RF092-13/50 Series Nisso Dekalo Import Export LTD 1 David Hamelech Street Herzlia 46661 Israel Tel: +972 99577888 Fax: +972 99568860 [email protected] www.fly-supply.net www.aircraft-partsupply.com Via Tertulliano, 41 20137 Milano, Italy Tel: +39 02 55187133 Fax: +39 02 55187399 [email protected] www.fae.it Althen Sensors & Controls BV OptoCom InstruVentures Haabersti linnaosa, Astangu tn 52 13519 Eesti, Tallinn, Estonia Tel: +372 56363110 [email protected] H-49-2, Jalan 5, Cosmoplex Industrial Park, Bandar Baru Salak Tinggi, Sepang, Malaysia...

 Open the catalog to page 12
Laminated Tubes Geometry Measurement System Manual-13

Laminated Tubes Geometry Measurement System. RF092-13/50 Series SOUTH KOREA EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl EXCLUSIVE REPRESENTATIVE FOR RAILWAY EQUIPMENT ul. Wielowiejska 53, 44-120 Pyskowice, Poland Tel: +48 32 230 45 70 Fax: + 48 32 233 21 34 [email protected] [email protected] www.ascorail.pl SOUTH KOREA M-1001, Songdo techno park IT center, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, 21984, Republic of Korea Tel: +82 32 811 3457 Fax:...

 Open the catalog to page 13

All RIFTEK EUROPE catalogs and technical brochures

  1. RF62x Manual

    174  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.