1. Catalogs
  2. RIFTEK EUROPE
  3. Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН

Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН

Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН
1 / 30 PagesView full catalog

Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН

Product catalog summary
Safety Precautions and Measurement Conditions: Proper installation of the gauge is crucial to prevent distortions and impacts. Regular inspection and cleaning of the laser sensor windows are recommended.
CE Compliance: The gauge adheres to EU directives concerning electromagnetic compatibility and RoHS standards.
Laser Safety: The device uses a 660 nm semiconductor laser with a maximum output of 1 mW, classified as laser safety class 2. It is important to avoid directing the laser at humans and not to disassemble the sensor.
General Information: The gauge is designed for non-contact scanning and measurement of pipe inner diameters.
Basic Technical Data: The measurement range is 18-30 mm with an error margin of ±0.05 mm. It operates in temperatures from -10 to +50°C and has an IP42 enclosure rating.
Ordering Designation: The model is identified as RF096-Dmin/Dmax-Lmin/Lmax-HH, indicating diameter and depth measurement ranges.
Complete Set: The package includes a laser scanning module, calibration module, guide bush, nut, charger, data cable, and a protective case.
Device Structure: The device consists of a laser scanning module, guide bush with nut, calibration module, charger, and data cable.
Operating Principle: The gauge uses a rotating laser head to scan the inner surface of pipes, calculating parameters like diameter and roundness, with results displayed on a built-in screen.
Basic Settings: Users can configure settings such as date/time, language, synchronization with PC, database settings, and measurement type.
Calibration and Measurement: The device supports both single measurements and measurements according to a scheme, with data stored in a database for analysis.
Software and Synchronization: The gauge can synchronize with a PC via USB using ActiveSync or Mass Storage methods.
Technical Support and Warranty: The manual includes information on battery charging, technical support, and warranty policies.
Database Settings: Users can save measurement results to the PDA database, create new databases, and manage existing ones. The default naming convention for databases is based on the current date.
Measurement Type Selection: Two types of measurements are available: rapid measurements and measurements by scheme. Users can select and save the desired type.
Calibration and Measurement Settings: Calibration involves setting parameters such as calibration diameter and tolerance. The gauge must be calibrated before use to ensure accuracy.
Measurement Procedures: Measurements can be single or according to a scheme. The process involves inserting the gauge, checking sensor status, and saving results. Parameters like pipe diameter and wall thickness are measured, with out-of-tolerance values highlighted.
Database Browsing: Users can view saved data, apply filters, and visualize pipe profiles. The software allows for data sorting, filtering, and grouping.
PC Software Installation and Synchronization: The pipe_DB software is used for database management on a PC. Synchronization between the gauge and PC can be done via ActiveSync or Mass Storage.
User Settings: Users can configure parameters for viewing and calculating pipe data, specify database paths, and import data from other databases.
Data Exchange: Data can be transferred between the gauge and PC using USB synchronization methods, allowing for data import and export.
Technical Support and Warranty: Technical assistance is available for gauge issues, and the product comes with a 24-month warranty from the date of operation.
Distributors: Contact information for distributors in various countries is provided for purchasing and support.
See more

Catalog excerpts

Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-1

HANDHELD INNER DIAMETER MEASURING GAUGE RF096-18/30-155/307-HH Series User's manual www.riftek.com [email protected]

 Open the catalog to page 1
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-2

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series

 Open the catalog to page 2
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-3

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Safety precautions and measurement conditions · When installing the gauge into the channel, avoid distortions and strong impacts. · It is necessary to periodically inspect the windows of the laser sensor and clean them of dirt. The gauge has been developed for use in industry and meet the requirements of the following Directives: · EU directive 2014/30/EU. Electromagnetic compatibility (EMC). · EU directive 2011/65/EU, “RoHS“ category 9. Laser safety The gauge makes use of an c.w. 660 nm wavelength semiconductor laser. The...

 Open the catalog to page 3
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-4

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Basic technical data Parameter ID measurement range, mm ID measurement error, mm Discreteness of indication, mm Space resolution, points/turnover Measurement depth from the pipe end, mm Measurement time, not greater, s Measured parameters Value 18...30 ±0.05 0.01 700 155...307 2 diameters (min, max, average), ovality, roundness see Figure 4 Dimensions Power supply, V Number of measurements before recharging, not less Operating ambient temperature, °С Enclosure rating Laser sensor output power, mW Laser safety class Weight,...

 Open the catalog to page 4
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-5

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Device structure Basic components Figure 2 shows the main components of the gauge: Designations: (1) Laser scanning module (2) Guide bush with nut (3) Calibration module (4) Charger (5) Data cable

 Open the catalog to page 5
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-6

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Laser scanning module Figure 3 shows the main components of the laser scanning module: Designations: (1) Power button (2) Measurement button (3) Display (4) Charger connector (5) Guide shaft with a scale (6) Rotating laser head (7) Scale on a guide bush

 Open the catalog to page 6
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-7

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Overall dimensions of the laser scanning module are shown in Figure 4: Calibration module The module is designed to calibrate the gauge and check its performance. The overall dimensions of the module and the nut are shown in Figure 5:

 Open the catalog to page 7
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-8

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Operating principle The operation of the gauge is based on the principle of laser scanning of the inner surface of the pipe by a rotating laser head. The rotation of the laser head is carried out by a built-in motor. The gauge is equipped with a display for showing the result. The gauge operates as follows: the guide bush 2 (Figure 2) is installed at the end of the controlled hole by using a nut. The operator inserts the laser head into the pipe through the guide bush at a predetermined depth, which is counted on a scale marked...

 Open the catalog to page 8
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-9

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Basic settings Before you start working with the device, it is necessary to configure its basic parameters. In the main program window (see p. 10), tap the Device button: 9 Button Date/Time Language Synchronization Database Measure type Assignment Date/time settings. Program language selection. Synchronization with PC. Database settings. Measurement type selection (rapid measurement or measurement according to the scheme). Date/time settings To set the date and time, tap the Date/Time button. Then use the buttons to set the...

 Open the catalog to page 9
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-10

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series To transfer data between PDA and PC, it is necessary to synchronize them. There are two ways of synchronization via USB cable. When you select MS ActiveSync, synchronization with PC is performed via the ActiveSync software (Windows XP), or via Windows Mobile Device Center (Windows 7). When you select Mass Storage, the device is detected in Windows as an external storage device. To select the type of synchronization, tap the Synchronization button in the Device window. Then select the required type and tap Save. For the changes...

 Open the catalog to page 10
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-11

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series To create a new database, tap the Add button. The window for entering a name of the new database will appear. By default, it will be prompted to form the database file with the name db_yy_mm_dd.idt, where yy_mm_dd is the current date: yy – the last two digits of the year; mm – month; dd – day. You can agree with this name, or enter another: After typing the name, tap the Enter button - To select the database from a list, tap on the line and then tap Select. The selected file will be marked with a "dot" symbol. To delete the...

 Open the catalog to page 11
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-12

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Calibration and measurement settings To configure calibration and measurement settings, tap the Settings button in the main program window. 12 To make changes, you need to select the required parameter and enter the new value in the Data Input window. Then tap the Enter button - To save the changes, tap the Save button. Description of parameters: Parameter Calibration diameter Calibration tolerance Inner diameter Outer diameter Measurement tolerance Description Calibration ring diameter. Tolerance for calibration and testing....

 Open the catalog to page 12
Handheld Inner Diameter Measuring Gauge, Manual, RF096-18/30-155/307-НН-13

Handheld Inner Diameter Measuring Gauge. RF096-18/30-155/307-HH Series Parameter Reference D Reference T Measured D Measured T Description Calibration ring diameter. Tolerance for calibration and testing. Measured diameter. Deviation from the reference value. · Tap the Calibration button. The gauge will scan the calibration ring and perform an automatic calibration. Then the gauge will scan the calibration ring again in order to perform the testing procedure. If successful, you will see the following message: The Measured T column shows the difference between the actual value of the ring diameter...

 Open the catalog to page 13

All RIFTEK EUROPE catalogs and technical brochures

  1. RF62x Manual

    174  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.