TRICOR

TRICOR
1 / 15 PagesView full catalog

TRICOR

Product catalog summary
Overview: The Tricor Series Mass Flow Meters by Riels Instruments Srl utilize Coriolis technology to measure mass flow, volume flow, temperature, and density, making them suitable for diverse applications.
Principle of Operation: These meters operate on the Coriolis effect, where vibrating flow tubes experience a time delay due to mass flow, allowing for mass flow calculation. The resonant frequency aids in determining density, while temperature sensors adjust for temperature variations.
Applications: Ideal for measuring the flow of PU components, paints, and aggressive or contaminated media, these meters measure mass flow, density, temperature, and volume flow.
Features: Notable features include a maximum pressure of 350 bar, rapid response time, DKD calibration, excellent purging and sterilization capabilities, and temperature tolerance up to +150°C. They also comply with Ex protection standards (ATEX, IECEx, CSA cUs).
Technical Specifications: Detailed specifications are provided for models like TCM0325 to TCM65k, covering flow ranges, accuracy, density measuring range, temperature accuracy, and process connections. Constructed from stainless steel, they offer various housing options.
Transmitter and Display Options: The TCE 8000 and TCE 6000 transmitters feature graphic displays, multiple interfaces (RS 485, HART, Foundation Fieldbus), and diverse output configurations. The TRD 8001 remote display enhances remote monitoring capabilities.
Ex Certifications: Certified for hazardous areas, these meters have ATEX Zone 1 and 2, IECEx, and CSA Ex Division 1 certifications.
Dimensional Drawings: Dimensional drawings for various models and configurations are included, offering detailed installation and integration measurements.
Ordering Information: The datasheet provides ordering codes for different configurations, including mechanical options, electronics, terminal options, and Ex-protection levels.
See more

Catalog excerpts

TRICOR-1

MISURATORE MASS Certified according to DIN EN ISO 9001 MASSICO - CORIOLIS FLOW METER CORIOLIS TECHNOLOGY Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Technical Datasheet TRICOR Series Mass Flow Meters

 Open the catalog to page 1
TRICOR-2

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Flow measurement of aggressive and contaminated media Due to a construction free of dead spots the meters are well flushable and can be easily sterilized. Flow measurement of PU components and paints The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different measuring instruments. Measurement of mass flow, density, temperature and volume flow The Tricor Mass Flow Meters do not contain any moving parts and consequently are suited...

 Open the catalog to page 2
TRICOR-3

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Compact version with TCE 8000 Exd housing for wall-mounting (separated version, also with flange ends) Remote panel-mounted housing (separated version, also with flange ends) Compact version with TCE 6000 and TRD 8001 Compact version with KCE 8000 ATEX / IECEx

 Open the catalog to page 3
TRICOR-4

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Data - TCM Transducer TCM0325 Flow range (kg/h) Flow range (lb/min) Flow range (l/h) Basic Accuracy (% of flow reading) Zero Stability (% of full scale) Density measuring range Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Density accuracy Temperature accuracy Process and Ambient Process connections female thread 1/2“ adaptors for flanges, diary and tri-clamp Pressure Drop at max. flow H20 Operating Density range 500 - 2,500 kg/m³ (standard) , 5...

 Open the catalog to page 4
TRICOR-5

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Data - TCE 8000 Transmitter General Display Supply votage RS 485, Option HART®, option Foundation Fieldbus Power consumption internal clamp terminals cable gland for 7 - 13 mm cables aluminium diecast Protection class Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments operating: - 40 up to 70°C (up to + 80°C on request) storage and transport: -40 up to 80°C Panel-mounted housing: Dimensions rear clamp terminals Protection class operation: 0 to 60°C storage...

 Open the catalog to page 5
TRICOR-6

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Data - TCE 6000 Transmitter General Supply voltage Power consumption aluminium diecast Ingress protection Analog Outputs Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Current output Temperature drift Output value programmable: flow, total, density, temperature Pulse Output Frequency range: Output signal: active push pull output for flow rate Status In-and Output Status output Push Pull programmable (option) Control input programmable (standard: 1...

 Open the catalog to page 6
TRICOR-7

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Zone 1: Group IIC or IIB, T4 Zone 2: II 3G Ex nA IIC T4 Gc Basic Accuracy + Zero Stability ∗ Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments max. Flow Current Flow

 Open the catalog to page 7
TRICOR-8

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments * further lengths on request ** flange types on request

 Open the catalog to page 8
TRICOR-9

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Dimensional drawing (mm) On site Electronics „C“ Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Dimensional drawing (mm) Big on site Electronics „E“

 Open the catalog to page 9
TRICOR-10

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Dimensional drawing (mm) On site Electronics TCE 6000 Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Dimensional drawing (mm) Connection Head

 Open the catalog to page 10
TRICOR-11

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments

 Open the catalog to page 11
TRICOR-12

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Dimensional drawing (mm) TCE 80xx - E with cable connection Dimensional drawing (mm) TCE 80xx - E with Junction Box 189 Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments

 Open the catalog to page 12
TRICOR-13

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Dimensional drawing (mm) Panel-Mounted Housing (drawing not to scale) Dimensional drawing (mm) Remote Display TRD 8001 Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments

 Open the catalog to page 13
TRICOR-14

Tricor - Mass Flow Meter MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Ordering Code (4 digit) Maximum Flow in kg/h code Ax Dx Fx process connections (2 digits) ANSI flange x = size of flange, contact KEM / AWL for code DIN flange x = size of flange, contact KEM / AWL for code Female thread x = size of thread, contact KEM / AWL for code code X000 Mechanical options (4 digits) Temperature range S = -20 to 100°C H = -20 to 150°C Pressure range G = 100bar with rupture disc For other ranges contact KEM Accuracy (S = standard) Flange to flange length, contact KEM/AWL for code Tutti...

 Open the catalog to page 14
TRICOR-15

MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY (4 digits) Low Power Electronics High Power Electronics code W S E L housing (1 digit) Wall-mounted housing with fixed cable to TCM Panel-mounted housing (separate cable required) Big wall-mounted housing with fixed cable to TCM or with junction box Wide panel-mounted housing (separate cable required) (Ex) code Options (4 digits) Interface S = RS 485 only A = Hart + RS 485 B = Foundation Fieldbus + RS485 C = HART + Foundation Fieldbus + RS485 D = Foundation Fieldbus only E = Hart + Foundation Fieldbus Z = not used Power Supply...

 Open the catalog to page 15

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. FFU

    7  Pages

  11. RIF600W

    4  Pages

  12. RIF180

    3  Pages

  13. MC 505

    1  Page

  14. HM-R

    3  Pages

  15. HD408T

    2  Pages

  16. RIB300

    3  Pages

  17. 23/25 ED

    2  Pages

  18. RIB180

    4  Pages

  19. FLD48

    2  Pages

  20. CLM-36

    6  Pages

  21. DLM-35

    2  Pages

  22. DLS-27

    7  Pages

  23. CLS-23

    5  Pages

  24. PFG05/ATFHV60

    2  Pages

  25. LFP

    2  Pages

  26. GRLM70

    9  Pages

  27. RIL600

    5  Pages

  28. LITTLE EX

    1  Page

  29. MATIC/V/MC

    2  Pages

  30. DCX22

    2  Pages

  31. MN03

    1  Page

  32. LEO RECORD

    2  Pages

  33. EV220B

    13  Pages

  34. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.