TCA_Compact_Temperature_switches_Riels-1

Compact temperature switches explosionproof Execution Electric construction Degree of protection: IP65 (NEMA 4). - Dust-protected enclosure: Ex-tD A2I IP65T85 andTI 35 Electrical safety class: class I (EN61298-2:1997-06) Case and cover copper free aluminium alloy, threaded coupling with tam- per proof device. Epoxy exterior painting, grey colour Cable entry: 1/2-14 NPT-F (std) (see point 4). Terminal block: suitable for wires section 1,5 mm2 (minimum 0,5 mm2). Insulating material toVDE standard. Earthing screws: one Inside, one outside. Max section of earthing wires: 4 mm2. Electric contacts (See point 1.4) One micro, SPDT or DPDT, with fixed dead band. Vapor tension system to SAMA II C or II A, consisting of: - Connection AISI 304 compression fitting with adjustable nsertion length. - Capillary AISI 3 I 6 with stainless steel flexible armor Adjustable throughout the range. Repeatability: better than I % of span. Scale: the Instrument Is fitted as std. with an approximate scale of the set point Indication. - Remote at surface (std.) or 2" pipe (with optional bracket), sensors type Ambient temperature (operative limit1): Directive ATEX 94/9/EC Group II Category 2GD Annex lll + IV REMOTE (SENSORTYPE "C/Q/R") DIRECT (SENSORTYPE "B") Riels Instruments Sri . W +39 049 8961771 - A +39 049 7l7368 .www.riels.it. [email protected]

 Open the catalog to page 1
TCA_Compact_Temperature_switches_Riels-2

Model code - Setting range - Pressure connection thread - Cable entry thread - Options if any - Versions. MODEL CODE Enclosure code Sensor code (D On instrument nameplate, data underlined only © Simultaneous action to within 2% of span. Scientific Apparatus Makers Association SETTING RANGES working range Proof temperature Classification of the thermal system. BULB CONNECTIONS CABLE ENTRY Helical bulb (ranges -15/+40°C & +10/+70°C) height between bulb/enclosure: Yean be varied up to Ymax. THE LENGTH K AVAILABLE WILL BE REDUCED accordingly.

 Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. TRICOR

    15  Pages

  11. FFU

    7  Pages

  12. RIF600W

    4  Pages

  13. RIF180

    3  Pages

  14. MC 505

    1  Page

  15. HM-R

    3  Pages

  16. HD408T

    2  Pages

  17. RIB300

    3  Pages

  18. 23/25 ED

    2  Pages

  19. RIB180

    4  Pages

  20. FLD48

    2  Pages

  21. CLM-36

    6  Pages

  22. DLM-35

    2  Pages

  23. DLS-27

    7  Pages

  24. CLS-23

    5  Pages

  25. PFG05/ATFHV60

    2  Pages

  26. LFP

    2  Pages

  27. GRLM70

    9  Pages

  28. RIL600

    5  Pages

  29. LITTLE EX

    1  Page

  30. MATIC/V/MC

    2  Pages

  31. DCX22

    2  Pages

  32. MN03

    1  Page

  33. LEO RECORD

    2  Pages

  34. EV220B

    13  Pages

  35. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.