Group: Riels Instruments
Catalog excerpts
Compact temperature switches explosionproof Execution Electric construction Degree of protection: IP65 (NEMA 4). - Dust-protected enclosure: Ex-tD A2I IP65T85 andTI 35 Electrical safety class: class I (EN61298-2:1997-06) Case and cover copper free aluminium alloy, threaded coupling with tam- per proof device. Epoxy exterior painting, grey colour Cable entry: 1/2-14 NPT-F (std) (see point 4). Terminal block: suitable for wires section 1,5 mm2 (minimum 0,5 mm2). Insulating material toVDE standard. Earthing screws: one Inside, one outside. Max section of earthing wires: 4 mm2. Electric contacts (See point 1.4) One micro, SPDT or DPDT, with fixed dead band. Vapor tension system to SAMA II C or II A, consisting of: - Connection AISI 304 compression fitting with adjustable nsertion length. - Capillary AISI 3 I 6 with stainless steel flexible armor Adjustable throughout the range. Repeatability: better than I % of span. Scale: the Instrument Is fitted as std. with an approximate scale of the set point Indication. - Remote at surface (std.) or 2" pipe (with optional bracket), sensors type Ambient temperature (operative limit1): Directive ATEX 94/9/EC Group II Category 2GD Annex lll + IV REMOTE (SENSORTYPE "C/Q/R") DIRECT (SENSORTYPE "B") Riels Instruments Sri . W +39 049 8961771 - A +39 049 7l7368 .www.riels.it. info@riels.it
Open the catalog to page 1Model code - Setting range - Pressure connection thread - Cable entry thread - Options if any - Versions. MODEL CODE Enclosure code Sensor code (D On instrument nameplate, data underlined only © Simultaneous action to within 2% of span. Scientific Apparatus Makers Association SETTING RANGES working range Proof temperature Classification of the thermal system. BULB CONNECTIONS CABLE ENTRY Helical bulb (ranges -15/+40°C & +10/+70°C) height between bulb/enclosure: Yean be varied up to Ymax. THE LENGTH K AVAILABLE WILL BE REDUCED accordingly.
Open the catalog to page 2All Riels Instruments catalogs and technical brochures
-
RIV110 Flow switch
2 Pages
-
miniELCOR
4 Pages
-
EL-USB-4
5 Pages
-
EE33
6 Pages
-
EE300Ex-HT
6 Pages
-
Temperature Sensors
64 Pages
-
AVFM 5.0
3 Pages
-
EE 75
5 Pages
-
EE776
6 Pages
-
EE771/2
6 Pages
-
TRICOR
15 Pages
-
SE 404 X SE 406 X
2 Pages
-
FFU
7 Pages
-
RIF600W
4 Pages
-
RIF180
3 Pages
-
MC 505
1 Pages
-
HM-R
3 Pages
-
HD408T
2 Pages
-
RIB300
3 Pages
-
23/25 ED
2 Pages
-
RIB180
4 Pages
-
FLD48
2 Pages
-
CLM-36
6 Pages
-
DLM-35
2 Pages
-
DLS-27
7 Pages
-
CLS-23
5 Pages
-
PFG05/ATFHV60
2 Pages
-
LFP
2 Pages
-
GRLM70
9 Pages
-
RIL600
5 Pages
-
LITTLE EX
1 Pages
-
DEEPER
1 Pages
-
DCX22
2 Pages
-
RIV165 Paddle Flow Switches
2 Pages
-
RIV170 Paddle Flow Switch
2 Pages
-
RIV100 Flow switch for air
1 Pages
-
RIV150 Flow switch
2 Pages
-
Riels® Instruments Catalog
24 Pages
-
MN03
1 Pages
-
LEO RECORD
2 Pages
-
EV220B
13 Pages
-
WWG
1 Pages
-
LEO2_Digital_Manometer_Riels
1 Pages
-
LEO1_Digital_Manometer_Riels
1 Pages
-
FAM_Air_flowmeter_riels
1 Pages
-
MATIC/V/MC
2 Pages