Overview
The RIL160 is a hydrostatic level transmitter designed for measuring levels in various liquid environments, including dirty and waste water. It utilizes piezoresistive silicon measurement technology and advanced microprocessor signal conditioning for high accuracy and reliability across a wide temperature range.

Key Features
  • Non-fouling diaphragm design
  • Resistant to chemical attacks with AISI 316SS housing
  • Digital interface RS485
  • Rangeable analog output
  • Enhanced reliability in lightning-prone areas

Applications
  • Level measurement in wells, tanks, lakes, ponds, and fuel tanks
  • Control and measurement in leachate plant biomass and artificial lakes
  • Monitoring pump operations and alert levels in manholes

Performance Specifications
  • Pressure Range: 0-0.5 to 200 mH2O
  • Operating Temperature: -20 to +70°C
  • Compensated Temperature Range: 0 to 50°C
  • Output Signal Options: 0...20 mA, 4...20 mA, 0…5 VDC, 1…5 VDC, 1…10 VDC, 0.5…4.5 VDC, RS485, Hart protocol
  • Power Supply: 5VDC, 9VDC, 12VDC, 24VDC, 12…36VDC
  • Accuracy: ±0.25% FSO
  • Long-Term Stability: ±0.3% FSO

Physical Specifications
  • Housing: 304 stainless steel, optional 316SS
  • Diaphragm: 316L stainless steel, optional ceramic
  • Cable: PUR, PE, PTFE
  • Protection: IP68
  • Net Weight: Approx. 400g

Ordering Information
  • Model Types: RIL160-A, RIL160-B
  • Pressure Range Options: 0.5mH2O to 200mH2O
  • Cable Length: Customizable
  • Output Signal Options: Various including RS485 Modbus RTU
  • Accuracy Options: 0.1%FS to 0.5%FS
  • Electrical Connection: PUR, PE, PTFE cables
  • Housing Material Options: 304, 316, 316L Stainless steel, Titanium alloy
  • Diaphragm Material Options: 316L Stainless steel, Ceramic, Titanium, Tantalum alloy
See more

Catalog excerpts

RIL160 Hydrostatic Level Transmitter waste water-1

LEVEL CONTROLS IMMERSION LEVEL TRANSMITTER RIL160 Hydrostatic level transmitter. Suitable for dirty water, waste water The RIL160 level transmitteruses proven piezoresistive silicon measurement technology, in combination with Riels’ most advanced microprocessor signal conditioning circuitry, to deliver maximum accuracy and reliability over a wide compensated temperature range. It is perfectly suited for pump control applications that require transmitters with standard 2-wire (4÷20 mA current loop) or 3-wire (0÷10 V) output. The RS485 interface allows users to scale the analog output with respect to any required range, including within the standard range of pressure variation. In normal configuration, the RIL160 is held in suspension inside the liquid by a standard cable with PUR sheath (PE, PTFE required), which is selfsupporting and is equipped with vent holes. Upon request, Riels’ enhanced lightning protection makes this transmitter ideal for installations in areas prone to chronic damage due to lightninginduced voltage transients.. Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments • Non-fouling diaphragm design • Housing resist chemical attack (AISI 316SS) • Digital interface RS485 • Rangeable analog output • Increased reliability in lightning-prone regions Performance Specifications • Level measurement in wells • Level measurement in tanks • Level measurement of leachate plant biomass • Level measurement in lakes and ponds • Measurement and control level artificial lakes • Level measurement of fuel tanks • Check operation of pumps • Level measurement of dark waters • Level measurement fish tanks • Check alert level manholes General Pressure Range Environmental Operating Temp.Range Compensated Temp.Range Electrical @25°C(77°F) Output Signal Power Supply Load Resistance Insulation Resistance Physical Specifications Housing 304 stainless steel, option 316SS 316L stainless steel, option ceramic Performance Accuracy** Temp. Coeff– Zero*** Temp. Coeff– Span*** Long-Term Stability * All values measured at 25°C(77°F)** Including non-linearity, hysteresis and repeatability. ***0°C to 70°C(32°F to 158°F) with reference to 25°C (77°F).The listed specifications and dimensions are subject to change without prior notice Riels

 Open the catalog to page 1
RIL160 Hydrostatic Level Transmitter waste water-2

Type A (See the dimension drawing) Type B (See the dimension drawing) Pressure range 0.5mH2O 0001 Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Customer Cable length [x]m x=cable length Output Signal 42 4…20 mA + HART communication Accuracy 01 Customer Electrical Connection 1 PTFE cable Housing 0 Titanium alloy Diaphragm 6 Titanium alloy Tantalum alloy

 Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. TRICOR

    15  Pages

  11. FFU

    7  Pages

  12. RIF600W

    4  Pages

  13. RIF180

    3  Pages

  14. MC 505

    1  Page

  15. HM-R

    3  Pages

  16. HD408T

    2  Pages

  17. RIB300

    3  Pages

  18. 23/25 ED

    2  Pages

  19. RIB180

    4  Pages

  20. FLD48

    2  Pages

  21. CLM-36

    6  Pages

  22. DLM-35

    2  Pages

  23. DLS-27

    7  Pages

  24. CLS-23

    5  Pages

  25. PFG05/ATFHV60

    2  Pages

  26. LFP

    2  Pages

  27. GRLM70

    9  Pages

  28. RIL600

    5  Pages

  29. LITTLE EX

    1  Page

  30. MATIC/V/MC

    2  Pages

  31. DCX22

    2  Pages

  32. MN03

    1  Page

  33. LEO RECORD

    2  Pages

  34. EV220B

    13  Pages

  35. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.