Overview
The document provides technical specifications and benefits of the Radar Level Meter with Guided Wave technology, designed for hygienic applications. It features a manually cuttable monoprobe, suitable for process temperatures up to 150°C and pressures up to 16 bar, with CIP/SIP resistance and IP67/IP69K enclosure ratings.

Key Specifications
  • Probe Length: Up to 2,000 mm, manually cuttable
  • Process Temperature: -20°C to 150°C
  • Process Pressure: -1 bar to 16 bar
  • Enclosure Rating: IP67 and IP69K
  • Output: Analog (4-20 mA / 0-10 V) and two binary outputs
  • Approvals: EHEDG, GOST, RoHS

Benefits
  • Robust design for increased service life
  • High flexibility with cuttable probe and interchangeable connections
  • Cost-effective with multiple output signals for level detection and monitoring
  • No calibration required, saving time and costs

Performance and Electrical Data
  • Dielectric Constant: ≥ 5
  • Repeatability: ≤ 2 mm
  • Resolution: < 2 mm
  • Accuracy: ± 5 mm
  • Supply Voltage: 12 V DC to 30 V DC
  • Power Consumption: ≤ 75 mA at 24 V without output load
  • Response Time: < 400 ms

Mechanical and Ambient Data
  • Housing Material: 303
  • Process Connection: G 3/4 A
  • Wetted Parts: 316L (Ra ≤ 0.8 μm), PEEK
  • Ambient Temperature (Operation): -20°C to 60°C
  • Ambient Temperature (Storage): -40°C to 80°C

Dimensional Drawing
The document includes a dimensional drawing with details on connection types and inactive areas at the process connection and probe end.
See more

Catalog excerpts

LFP Radar level meter with guided wave Riels-1

RADAR LEVEL METER GUIDED WAWE Radar level meter with guided wawe At a glance • Level monitoring in hygienic applications • Manually cutable monoprobe up to 2,000 mm long with Ra 0.8 μm • Process temperature up to 150 °C, process pressure up to 16 bar • CIP/SIP resistant • IP 67 and IP 69K enclosure rating • Interchangeable hygienic process connections • 3-in-1: combined display, analog output and binary output • Analog output 4 mA ... 20 mA / 0 V … 10 V, switchable, plus two binary outputs Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Your benefits • Robust design increases service life • High flexibility due to cutable probe and interchangeable connection concept • Cost savings due to multiple output signals: one system for both level detection and continuous level monitoring • Time and cost savings due to low maintenance and quick commissioning • No calibration or recalibration required for commissioning, thus saving time and costs Features Medium Measurement Probe length Process pressure Process temperature EHEDG approval GOST approval RoHS certificate Fluids switch, continuous 300 mm -1 bar ... 16 bar -20 °C ... 150 °C √ √ √ Mechanical data Performance Dielectricity constant Repeatability Resolution Accuracy of sensor element Conductivity Inactive area at process connector Inactive area at probe end 1) 2) Housing material Process connection Wetted parts Max.probe load Ambient data With parameterized tank with water under reference conditions, otherwise 40 mm With water under reference conditions Ambient temperature, operation Ambient temperature, storage Electrical data Supply voltage Power consumption Initialization time Connection type Response time Signal voltage HIGH Signal voltage LOW Output current 12 V DC ... 30 V DC 1) ≤ 75 mA at 24 V without output load ≤2s M12x1, 5-pin < 400 ms Vs - 2 V ≤2V < 100 mA 0 V ... 10 V > 750 Ohm at Uv ≥ 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V 20 mA ... 20.5 mA 3.8 mA ... 4 mA 100 nF <1H IP 67: EN 60529, IP 69K: EN 40050 < 0.1 mm/K III EN 61326-1:2006, 2004/108/EG EN 61000-6-2:2005 EN 61000-6-4:2007 EN 60068-2-27 EN 60068-2-29 Output load Upper signal level Lower signal level Capacitive load Inductive load Enclosure rating Temperature drift Protection class EMC Interference resistance Interference emission Single shock Continuous shock 1) All connections are polarity protected. All outputs are overload and short-circuit protected.

 Open the catalog to page 1
LFP Radar level meter with guided wave Riels-2

Dimensional drawing M: Measuring range L: Probe length IA: Inactive area at process connection 25 mm (0.79'') / 40 mm (1.58'') IAE: Inactive area at probe end 10 mm (0,39'') All dimensions in mm (inch) Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Connection type |1| L+: Supply voltage, brown |2| QA: Analog current-/voltage output, white |3| M: Ground, OUT - for current-/voltage output, blue |4| C/Q1: Switching output 1, PNP/IO-Link-communication, |5| Q2: Switching output 2, PNP/NPN, grey

 Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. TRICOR

    15  Pages

  11. FFU

    7  Pages

  12. RIF600W

    4  Pages

  13. RIF180

    3  Pages

  14. MC 505

    1  Page

  15. HM-R

    3  Pages

  16. HD408T

    2  Pages

  17. RIB300

    3  Pages

  18. 23/25 ED

    2  Pages

  19. RIB180

    4  Pages

  20. FLD48

    2  Pages

  21. CLM-36

    6  Pages

  22. DLM-35

    2  Pages

  23. DLS-27

    7  Pages

  24. CLS-23

    5  Pages

  25. PFG05/ATFHV60

    2  Pages

  26. LFP

    2  Pages

  27. GRLM70

    9  Pages

  28. RIL600

    5  Pages

  29. LITTLE EX

    1  Page

  30. MATIC/V/MC

    2  Pages

  31. DCX22

    2  Pages

  32. MN03

    1  Page

  33. LEO RECORD

    2  Pages

  34. EV220B

    13  Pages

  35. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.