LEX1 Highly Precise Digital Manometer Riels
2Pages

{{requestButtons}}

Catalog excerpts

LEX1 Highly Precise Digital Manometer Riels - 1

DIGITAL MANOMETER PRESSURE CONTROLS Highly Precise Digital Manometer Precision (0,01 % FS*) RS485 BUS Interface LEX1 is a micro-processor controlled, accurate and versatile digital pressure measuring instrument for calibration and testing purposes with 0,05 %FS standard accuracy. Option for precision 0,01% available as extra feature. Via the RS485 Bus Interface, communication with up to 128 connected instrument can take place. The pressure is measured twice per second and displayed. The top display indicates the actual pressure, the bottom display shows the Max. or Min. pressure. ATEX / IECEx: LEX1 devices which are marked with “LEX1 Ei” are intrinsically safe for use in hazardous areas (by approval for both ATEX and IECEx standards). Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Function LEX1 has two operating keys.The left key is to turn the instrument on, to select the functions and the pressure units. The right key executes the selected function resp. unit or serves to display the Max. and Min. value. The instrument has the following functions RESET With the RESET-function, the Max. and Min.value is set to the actual pressure value. ZERO Using the Zero-function will set any prevailing pressure to be the new zero point reference. CONT The instrument turns off 15 min. after the last key function. Activating CONT(Continuous) deactivates this automatic turn-off. UNITS All standard instruments are calibrated in bar. The pressure can be indicated in 13 different units. Scope of Delivery: Carrying case and 5-point calibration certificate. LEX1 with piezo-resistive pressure sensor Optional accessories - Carrying bag, protective rubber covering - Iinterface converter K-114A Number of Digits of the LCD Display Measuring Rate (Display LCD) Measuring Rate via Serial Interface 2 x per second Pressure up to 15 x per second Storage / Operating Temperature Medium Temperature Pressure Sensor Compensated Temperature Range Battery Battery Life approx. 2’000 hours continuous operation Pressure Connection G1/4” (other threads on request) Electrical Connection (****) External supply and RS485 communication via Fischer D103A054, flange socket fits with PC-converter cable K-114A (USB to RS485) External Supply (****) Temperature Measurement Material in Contact with Media Stainless Steel (AISI 316L), Viton® O-ring. In addition with LEX1 capacitive: gold plated ceramic diaphragm, Nitril O-ring Diameter x Height x Depth (approx.) Weight (approx.) LEX1 with capacitive pressure sensor LEX1 piezoresistive: 76x118x55 mm LEX1 capacitive: 76x148x55 mm LEX1 piezoresistive: 300 g. LEX1 capacitive 335 g. (****) In the Ex-Zone, the LEX1 Ei gauges are not allowed to be supplied externally, nor can they be connected via the RS485 interface. “Accuracy” is an absolute term, “Precision” a relative term. Dead weight testers are primary standards for pressure, where the pressure is defined by the primary values of mass, length and time. Highest class primary standards in national laboratories indicate the uncertaintyof their pressure references with 70 to 90 ppM or close to 0,01%. Commercial dead weight testers as used in our facilities to calibrate the transmitters and manometers indicate an uncertainty or accuracy of 0,025%. Below these levels, RIELS use the expression “Precision” as the ability of a pressure transmitter or manometer to be at each pressure point within 0,01 %FS relative to these commercial standards. The manometer’s full-scale output can be set up to match any standard of your choice by correcting the gain with a calibration software.

Open the catalog to page 1
LEX1 Highly Precise Digital Manometer Riels - 2

Accuracy, Error Band (0...50 °C): < 0,2 %FS LongTerm Stability: FS > 100 mbar: ± 0,1 %FS FS < 100 mbar: ± 0,1 mbar (**) Other pressure ranges as well as instruments with relative pressure measuring cells, on request (***) For the PD version, a tube connection 0 6 mm for the reference is available PR = Vented Gauge. Zero at atmospheric pressure PA = Absolute. Zero at atmospheric pressure PAA = Absolute. Zero at vacuum The factory setting of the zero for the ranges <61 bar absolute is at vacuum (0 bar absolute). For relative pressure measurements, activate "ZERO SEt" at ambient pressure....

Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. miniELCOR

    4 Pages

  2. EL-USB-4

    5 Pages

  3. EE33

    6 Pages

  4. EE300Ex-HT

    6 Pages

  5. AVFM 5.0

    3 Pages

  6. EE 75

    5 Pages

  7. EE776

    6 Pages

  8. EE771/2

    6 Pages

  9. TRICOR

    15 Pages

  10. FFU

    7 Pages

  11. RIF600W

    4 Pages

  12. RIF180

    3 Pages

  13. MC 505

    1 Pages

  14. HM-R

    3 Pages

  15. HD408T

    2 Pages

  16. RIB300

    3 Pages

  17. 23/25 ED

    2 Pages

  18. RIB180

    4 Pages

  19. FLD48

    2 Pages

  20. CLM-36

    6 Pages

  21. DLM-35

    2 Pages

  22. DLS-27

    7 Pages

  23. CLS-23

    5 Pages

  24. LFP

    2 Pages

  25. GRLM70

    9 Pages

  26. RIL600

    5 Pages

  27. LITTLE EX

    1 Pages

  28. DEEPER

    1 Pages

  29. DCX22

    2 Pages

  30. MN03

    1 Pages

  31. LEO RECORD

    2 Pages

  32. EV220B

    13 Pages

  33. WWG

    1 Pages

  34. MATIC/V/MC

    2 Pages