FS Pitot Tube Flowmeter Riels Instruments
1Pages

{{requestButtons}}

Catalog excerpts

FS Pitot Tube Flowmeter Riels Instruments - 1

PITOT TUBE flow FLOWMETER CONTROLS Tutti i dati ed i contenuti di questa scheda sono di proprieta esclusiva di Riels Instruments FS Pitot's Tube Measurer The measurer FS-2007 is a Pitot tube tool used for measuring the fluid speed and founds his operation on the definition of total pressure. A Pitot tube is furnished in fact of two pressure intakes, one to the anterior extremity perpendicularly prepared to the tide (total intake) and one on the body of the tube tangentially prepared to the fluid (statics intake). In this case the Pitot tube is gotten in an unique piece of plexiglas. The measurement is effectuated putting the tube in the tide of the fluid, where a perpendicular hole will practise preventively to the pipeline. The measurer is fixed with two metallic wrappers. A mediate plain gasket among the pipeline and the measurer avoid losses of pressure. The FS-2007 is an innovative instrument to have the great ranges in a small space. The facility of maintenance increases the possibilities of employment. In fact to be employed in filtration, purification, presurization and fireproof plants. Features: - Use: water - Accuracy: +/- 10% FS - Max working pressure: 10 bar - Max working temperature: 70°C - Body of the flow meter: PMMA - Float: in AISI 316 - Delivery: as per the table and expressed only in Lt/min Technical features General FS-2007 serie flowmeter should only be used on the size and type of pipe for which it was intended. Incorret use will result in in accurate readings and leakage problems. Installation Install the flowmeter with at least the minimum dimensions called for installation drawing.Carefully remove all burrs. Insert the pitot tube, with basket in place, into the drilled pipe. Tighten the clamps alternately a little at a time. Make certain the flow direction is towards the pitot tube opening. Cleaning The flowmeter body and all other parts can be cleaned by washing in a mild soap and water solutions. A soft bristle brush will simplify cleaning inside the meter body Note the floats up position for re-assembly We cannot guarantee our flowmters will not be damaged either at or below the suggested limits simply because of many factors which influence meter integrity; stress resulting from meter misalignment, damage due to excessive vibration and/or deterioration caused by contact with certain chemicals as well as direct sunlight. These situations and other tend to reduce the strength of the materials from which the meters are manufactured. Flowmeters are tested and calibrated only for water

Open the catalog to page 1

All Riels Instruments catalogs and technical brochures

  1. miniELCOR

    4 Pages

  2. EL-USB-4

    5 Pages

  3. EE33

    6 Pages

  4. EE300Ex-HT

    6 Pages

  5. AVFM 5.0

    3 Pages

  6. EE 75

    5 Pages

  7. EE776

    6 Pages

  8. EE771/2

    6 Pages

  9. TRICOR

    15 Pages

  10. FFU

    7 Pages

  11. RIF600W

    4 Pages

  12. RIF180

    3 Pages

  13. MC 505

    1 Pages

  14. HM-R

    3 Pages

  15. HD408T

    2 Pages

  16. RIB300

    3 Pages

  17. 23/25 ED

    2 Pages

  18. RIB180

    4 Pages

  19. FLD48

    2 Pages

  20. CLM-36

    6 Pages

  21. DLM-35

    2 Pages

  22. DLS-27

    7 Pages

  23. CLS-23

    5 Pages

  24. LFP

    2 Pages

  25. GRLM70

    9 Pages

  26. RIL600

    5 Pages

  27. LITTLE EX

    1 Pages

  28. DEEPER

    1 Pages

  29. DCX22

    2 Pages

  30. MN03

    1 Pages

  31. LEO RECORD

    2 Pages

  32. EV220B

    13 Pages

  33. WWG

    1 Pages

  34. MATIC/V/MC

    2 Pages