1. Catalogs
  2. Riels Instruments
  3. DCX22_Datalogger for pressure and temperature Riels

DCX22_Datalogger for pressure and temperature Riels

DCX22_Datalogger for pressure and temperature Riels

DCX22_Datalogger for pressure and temperature Riels

Product catalog summary
Overview
The Riels DCX-22 is a battery-powered, stainless steel datalogger designed for recording water depth (pressure) and temperature over extended periods. It is available in two versions: DCX-22 and DCX-22 SG/VG, each with distinct features for data collection and retrieval.

DCX-22 Version
This version houses the sensor, electronics, and battery in a sealed stainless steel tube for submersible deployment. Data retrieval requires recovering the device from the measurement point and accessing the data port by removing the O-ring sealed end cap. It uses an absolute pressure sensor, and for shallow water, a second DCX-22 (Baro) is recommended to record barometric pressure for accurate differential pressure calculations.

DCX-22 SG/VG Version
This version connects the sensor via a waterproof cable to a surface-mounted housing, facilitating easier data recovery. It does not require removal from the dip pipe for data readout. The SG version is sealed gauge, while the VG version is vented gauge, with a vent tube in the cable and a Gore-Tex® membrane-protected vent port.

Specifications
- Pressure Ranges: Various ranges available for different models, with options for absolute and vented gauge measurements.
- Battery Life: Up to 10 years with 1 measurement per hour.
- Output: RS 485 digital connection.
- Accuracy: High accuracy and resolution with compensation for linearity and temperature errors.
- Material: Stainless steel 316L with Viton® O-Ring.

Software and Data Management
The Logger 4.x software, compatible with Windows, is provided for configuring and reading data from RIELS data loggers. It supports graphical display, data export, and air pressure compensation. The software includes both a Writer for configuration and a Reader for data retrieval.

Writer Functions:
- Online display of measuring channels
- Record status indication
- Editing installation data
- Various start and recording methods

Reader Functions:
- Data readout and conversion into various formats
- Graphical data display
- Export for Excel import

Additional Features
The modular design allows for data collection via direct connection or optional GSM-1 unit for remote data transmission. The system is designed for easy installation and cost-effective setup compared to conventional systems.
See more

Catalog excerpts

DCX22_Datalogger for pressure and temperature Riels-1

DATALOGGER FOR PRESSURE AND TEMPERATURE Autonomous data collector 100% waterproof Riels DCX-22 is an autonomous, battery powered instrument made of stainless steel designed to record water depth (pressure) and temperature over long periods. Two versions are offered: DCX-22: The sensor, electronics and battery are housed in a sealed stainless steel tube, for submersible deployment. For data read-out the DCX-22 must be recovered from the measurement point. The O-ring sealed end cap is then removed to access the data port. The DCX-22 works with an absolute pressure sensor. In shallow water depths where the influence of barometric pressure changes should be considered, it is recommended that a second data collector DCX-22 (Baro) is placed at the surface, to record the barometric pressure. The PC then calculates the differential pressure resp. the water depth by subtracting the two measured values. Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments DCX-22 SG/VG: The sensor is connected by waterproof cable to a surface mounted housing with the data read-out port. This arrangement allows for easier data recovery from fixed installations. The DCX-22 SG/VG does not have to be removed from the dip pipe for data read out. The DCX-22 SG/VG is supplied with a 2” diameter fixing plate to enable mounting at the top of the dip pipe. The sensor can be sealed gauge SG, or vented gauge VG, the cable carries the vent tube for VG version sensors, vent port in the housing is protected by a breathable Gore-Tex® membrane. The electronics employ the latest microprocessor technology, which give high accuracy and resolution for the pressure and temperature signals from both the depth sensor and the barometric sensor. The measured values are mathematically compensated for all linearity and temperature errors of the pressure sensors. The use of a non-volatile memory ensures high data security. The electronics housing is mounted at the top of the borehole to give easy access for data downloading. The level sensor (diameter 22 mm) is connected via a sealed cable to the bottom of the electronics housing. Installation is quick and simple, using fixing devices in various sizes, suitable for cap lock units of different manufacturers and for well access points starting from 1” (caps starting at 2” include a hole to lower a dip meter). Thus enabling measuring stations to be set up at considerably lower costs compared to conventional systems. The modular design offers the user the two options for collecting the data. Standard design requires the user to visit the location, connect via data-cable and download data. The optional GSM-1unit allows the transmission of data, and instructions (re-programming) to the data-collector from/to a remote location. The data can be sent to any mobile phone as a short message (SMS). Version DCX-22 SG DCX-22 VG Pressure ranges Overpressuree DCX-22 Baro PAA DCX-22 PAA DCX-22 SG PAA DCX-22 VG PR 2 x Pressure range PAA: Absolute. Zero at vacuum. PR: Vented Gauge. Zero at atmospheric pressure (other ranges on request)

 Open the catalog to page 1
DCX22_Datalogger for pressure and temperature Riels-2

Specifications Supply Battery Life* Output Electrical Connection Lithium-Battery 3,6 V (Type AA) 10 years 1 measurement/hour RS 485 digital Fischer DEE 103A054 * Exterior influences could reduce battery life Pressure Sensor Specifications Linearity Comp. Temperature Range Error Band ** Resolution Long Term Stability Temperature Compensation Temperature Measurement Shortest Measuring Range Memory Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments Material Weight: Probe Tolerance System Length Options standard 0,02 %FS -10…40 °C standard 0,05 %FS *** max....

 Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. TRICOR

    15  Pages

  11. FFU

    7  Pages

  12. RIF600W

    4  Pages

  13. RIF180

    3  Pages

  14. MC 505

    1  Page

  15. HM-R

    3  Pages

  16. HD408T

    2  Pages

  17. RIB300

    3  Pages

  18. 23/25 ED

    2  Pages

  19. RIB180

    4  Pages

  20. FLD48

    2  Pages

  21. CLM-36

    6  Pages

  22. DLM-35

    2  Pages

  23. DLS-27

    7  Pages

  24. CLS-23

    5  Pages

  25. PFG05/ATFHV60

    2  Pages

  26. LFP

    2  Pages

  27. GRLM70

    9  Pages

  28. RIL600

    5  Pages

  29. LITTLE EX

    1  Page

  30. MATIC/V/MC

    2  Pages

  31. DCX22

    2  Pages

  32. MN03

    1  Page

  33. LEO RECORD

    2  Pages

  34. EV220B

    13  Pages

  35. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.