NextEnergy NXE - 1

Lithium compatible SmartGrid ready HIGHLIGHTS • Efficiency up to 97% in double conversion • kW = kVA (pf 1) up to 40 °C • Transformer-free UPS • Full front access, back-to-back installation • ACTIVE ECO Mode (active filter) • Colour LCD Touch Screen • Peak shaving The Riello UPS NextEnergy is the latest UPS series designed for mission critical applications as Data Centers, communication networks, commercial and industrial installations. The three-phase UPS offers transformerfree double conversion technology VFI SS 111, with integrated IGBT three-level design. NextEnergy is designed to offer unsurpassed performance and meets the power requirements of tomorrow. NextEnergy is fully scalable to evolve with growing business demands. It offers the highest level of power availability as well as reduced TCO, minimum energy consumption and CO2 emissions. Its unity power factor and easy system upgrading make it the ideal solution for the business continuity of any IT application. Thanks to its fault tolerant architecture, concurrent maintainability and hot scalability, NextEnergy guarantees continuous operation and premium protection for your customers’ business. ZERO IMPACT SOURCE AND PEAK DEMAND MANAGEMENT NextEnergy is designed with the latest technology to prevent disturbances on the mains and is able to “clean” the power from e.g. harmonics generated by nonlinear loads. The input AC/DC converter is based on the IGBT rectifier design using the latest 3-level technology. The key features are: • Input current distortion <3%; • Input power factor 0.99; • Power walk-

Open the catalog to page 1
NextEnergy NXE - 2

progressive rectifier start up; • start up delay function, to restart the rectifiers when mains power is restored. PEAK SHAVING FUNCTION Thanks to the possibility to set the maximum input power (kW or kVA), NextEnergy can be installed into AC supply systems with limited power availability such as a diesel generator or contractually reduced power sources and then supply the additional power required using the batteries (Peak Shaving function). NextEnergy offers 3 peak shaving operation modes: • Static: the NXE input power is programmed at commissioning time; • User Remote control: the user...

Open the catalog to page 2
NextEnergy NXE - 3

PEAK SHAVING FUNCTION FLEXIBILITY OF POSITIONING Against the wall EFFICIENCY CONTROL MODE (ECM) THE ACTIVE UPS WORKS IN A HIGHER EFFICIENCY WORKING POINT THE UPS WORKS IN A LOW EFFICIENCY WORKING POINT OPERATION MODES Manual Bypass Manual Bypass Static Bypass Static Bypass Rectifier LOAD Rectifier LOAD Manual Bypass Static Bypass

Open the catalog to page 3
NextEnergy NXE - 4

as business demands grow: • Parallel configuration up to 8 units NextEnergy UPS can be connected in parallel with up to 8 units to increase the capacity or add redundancy (N+1). Parallel configuration with common or separated battery is possible. • EFFICIENCY CONTROL Mode (ECM) Considering that a typical UPS load can vary from 20% to 80%, the ECM function optimises the operating efficiency of a parallel UPS configuration according to the power absorbed by the load: in case of low load, it sets some UPS in “freeze” mode, ensuring redundancy and a working point of the “live” UPS in the higher...

Open the catalog to page 4
NextEnergy NXE - 5

ADVANCED COMMUNICATION AND SUPERVISION NextEnergy offers wide communication and supervision tools and interface granting an easy integration into any building management system (BMS) and Data Center infrastructure (DCIM). • PowerShield3 monitoring and shutdown software for Windows operating systems 11, 10, 8, Server 2022, 2019, 2016 and previous versions, Windows Server Virtualization Hyper-V, macOS, Linux, Citrix XenServer and other Unix operating systems; • RielloConnect for remote monitoring service; • 2 slots suitable for the installation of the communication accessories such as network...

Open the catalog to page 5
NextEnergy NXE - 6

DETAILS NXE 250 (open front) MAINS SWITCH BYPASS SWITCH OUTPUT SWITCH MANUAL BYPASS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH OUTPUT SWITCH MAINS SWITCH OUTPUT SWITCH OUTPUT SWITCH MAINS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH MAINS SWITCH

Open the catalog to page 6
NextEnergy NXE - 7

DETAILS NXE 800 (open front) OUTPUT SWITCH MANUAL BYPASS SWITCH MAINS SWITCH BYPASS SWITCH

Open the catalog to page 7
NextEnergy NXE - 8

OPTIONS MULTI I/O MULTI PANEL Cold start Air filter kit ENERGYMANAGER PRODUCT ACCESSORIES Battery temperature sensor Isolation transformer Parallel kit Synchronisation device (UGS) Hot connection device (PSJ) IP21/IP31 versions, other on request ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 411 MULTICOM 421 BATTERY CABINET THREE-PHASE ISOLATION TRANSFORMERS Note: TBX ISO 800 T Dzn0 for NXE 800 available on request.

Open the catalog to page 8
NextEnergy NXE - 9

INPUT Rated voltage [V] Power factor Soft Start Standard equipment provided Backfeed protection, separate bypass line BATTERIES Type VRLA AGM / GEL, NiCd, Supercaps, Li-ion Ripple current Recharge voltage compensation OUTPUT Nominal Power [kVA] Static Stability Dynamic Stability Voltage distortion <1% with linear load/<3% with non-linear load Frequency stability on battery BYPASS Rated voltage [V] Frequency tolerance OVERALL SPECIFICATIONS Weight [kg] Input cable Remote signals Volt-free contact (configurable) Remote controls EPO, bypass battery charge block (configurable) USB + Dry...

Open the catalog to page 9
NextEnergy NXE - 10

INPUT Rated voltage [V] Power factor Soft Start Standard equipment provided Backfeed protection, separate bypass line BATTERIES Type VRLA AGM / GEL, NiCd, Supercaps, Li-ion Ripple current Recharge voltage compensation OUTPUT Nominal Power [kVA] Static Stability Dynamic Stability Voltage distortion <1% with linear load/<3% with non-linear load Frequency stability on battery BYPASS Rated voltage [V] Frequency tolerance OVERALL SPECIFICATIONS Weight [kg] Dimension (WxDxH) [mm] Input cable Remote signals Volt-free contact (configurable) Remote controls EPO, bypass battery charge block...

Open the catalog to page 10
NextEnergy NXE - 11

NextEnergy UPS PowerShield3 Mail Server Ethernet Switch Ethernet NextEnergy UPS NetMan 208 board Modbus/TCP Manager SNMP Manager Ethernet Switch Ethernet SNMP Protocol The information in this document is subject to change without notice. Riello UPS assumes no responsibility for any errors that may appear in this document. Modbus/TCP Protocol RPS SpA - Riello Power Solutions - Member of the Riello Elettronica Group Viale Europa, 7 - 37045 Legnago (Verona) - ITALY - Tel: +39 0442 635811 www.riello-ups.com

Open the catalog to page 11

All RIELLO UPS catalogs and technical brochures

  1. Master FC400

    2 Pages

  2. iDialog

    2 Pages

  3. iDialog Rack

    2 Pages

  4. Net Power

    2 Pages

  5. Sentinel Pro

    4 Pages

  6. Multi Switch

    2 Pages

  7. Powershiled3

    1 Pages

  8. iPlug

    3 Pages

  9. Master MPS

    8 Pages

  10. Vision

    3 Pages

  11. Vision Rack

    3 Pages

  12. Vision Dual

    4 Pages

  13. Sentryum

    11 Pages

  14. Multi Sentry

    5 Pages

  15. Multi Power2

    8 Pages

  16. Master HP UL

    4 Pages

Archived catalogs

  1. Guard Tower

    4 Pages

  2. Sentryum S3U

    4 Pages