Lithium compatible SmartGrid ready HIGHLIGHTS • Efficiency up to 97% in double conversion • kW = kVA (pf 1) up to 40 °C • Transformer-free UPS • Full front access, back-to-back installation • ACTIVE ECO Mode (active filter) • Colour LCD Touch Screen • Peak shaving The Riello UPS NextEnergy is the latest UPS series designed for mission critical applications as Data Centers, communication networks, commercial and industrial installations. The three-phase UPS offers transformerfree double conversion technology VFI SS 111, with integrated IGBT three-level design. NextEnergy is designed to offer unsurpassed performance and meets the power requirements of tomorrow. NextEnergy is fully scalable to evolve with growing business demands. It offers the highest level of power availability as well as reduced TCO, minimum energy consumption and CO2 emissions. Its unity power factor and easy system upgrading make it the ideal solution for the business continuity of any IT application. Thanks to its fault tolerant architecture, concurrent maintainability and hot scalability, NextEnergy guarantees continuous operation and premium protection for your customers’ business. ZERO IMPACT SOURCE AND PEAK DEMAND MANAGEMENT NextEnergy is designed with the latest technology to prevent disturbances on the mains and is able to “clean” the power from e.g. harmonics generated by nonlinear loads. The input AC/DC converter is based on the IGBT rectifier design using the latest 3-level technology. The key features are: • Input current distortion <3%; • Input power factor 0.99; • Power walk-
Open the catalog to page 1progressive rectifier start up; • start up delay function, to restart the rectifiers when mains power is restored. PEAK SHAVING FUNCTION Thanks to the possibility to set the maximum input power (kW or kVA), NextEnergy can be installed into AC supply systems with limited power availability such as a diesel generator or contractually reduced power sources and then supply the additional power required using the batteries (Peak Shaving function). NextEnergy offers 3 peak shaving operation modes: • Static: the NXE input power is programmed at commissioning time; • User Remote control: the user...
Open the catalog to page 2PEAK SHAVING FUNCTION FLEXIBILITY OF POSITIONING Against the wall EFFICIENCY CONTROL MODE (ECM) THE ACTIVE UPS WORKS IN A HIGHER EFFICIENCY WORKING POINT THE UPS WORKS IN A LOW EFFICIENCY WORKING POINT OPERATION MODES Manual Bypass Manual Bypass Static Bypass Static Bypass Rectifier LOAD Rectifier LOAD Manual Bypass Static Bypass
Open the catalog to page 3as business demands grow: • Parallel configuration up to 8 units NextEnergy UPS can be connected in parallel with up to 8 units to increase the capacity or add redundancy (N+1). Parallel configuration with common or separated battery is possible. • EFFICIENCY CONTROL Mode (ECM) Considering that a typical UPS load can vary from 20% to 80%, the ECM function optimises the operating efficiency of a parallel UPS configuration according to the power absorbed by the load: in case of low load, it sets some UPS in “freeze” mode, ensuring redundancy and a working point of the “live” UPS in the higher...
Open the catalog to page 4ADVANCED COMMUNICATION AND SUPERVISION NextEnergy offers wide communication and supervision tools and interface granting an easy integration into any building management system (BMS) and Data Center infrastructure (DCIM). • PowerShield3 monitoring and shutdown software for Windows operating systems 11, 10, 8, Server 2022, 2019, 2016 and previous versions, Windows Server Virtualization Hyper-V, macOS, Linux, Citrix XenServer and other Unix operating systems; • RielloConnect for remote monitoring service; • 2 slots suitable for the installation of the communication accessories such as network...
Open the catalog to page 5DETAILS NXE 250 (open front) MAINS SWITCH BYPASS SWITCH OUTPUT SWITCH MANUAL BYPASS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH OUTPUT SWITCH MAINS SWITCH OUTPUT SWITCH OUTPUT SWITCH MAINS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH MANUAL BYPASS SWITCH BYPASS SWITCH MAINS SWITCH
Open the catalog to page 6DETAILS NXE 800 (open front) OUTPUT SWITCH MANUAL BYPASS SWITCH MAINS SWITCH BYPASS SWITCH
Open the catalog to page 7OPTIONS MULTI I/O MULTI PANEL Cold start Air filter kit ENERGYMANAGER PRODUCT ACCESSORIES Battery temperature sensor Isolation transformer Parallel kit Synchronisation device (UGS) Hot connection device (PSJ) IP21/IP31 versions, other on request ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 411 MULTICOM 421 BATTERY CABINET THREE-PHASE ISOLATION TRANSFORMERS Note: TBX ISO 800 T Dzn0 for NXE 800 available on request.
Open the catalog to page 8INPUT Rated voltage [V] Power factor Soft Start Standard equipment provided Backfeed protection, separate bypass line BATTERIES Type VRLA AGM / GEL, NiCd, Supercaps, Li-ion Ripple current Recharge voltage compensation OUTPUT Nominal Power [kVA] Static Stability Dynamic Stability Voltage distortion <1% with linear load/<3% with non-linear load Frequency stability on battery BYPASS Rated voltage [V] Frequency tolerance OVERALL SPECIFICATIONS Weight [kg] Input cable Remote signals Volt-free contact (configurable) Remote controls EPO, bypass battery charge block (configurable) USB + Dry...
Open the catalog to page 9INPUT Rated voltage [V] Power factor Soft Start Standard equipment provided Backfeed protection, separate bypass line BATTERIES Type VRLA AGM / GEL, NiCd, Supercaps, Li-ion Ripple current Recharge voltage compensation OUTPUT Nominal Power [kVA] Static Stability Dynamic Stability Voltage distortion <1% with linear load/<3% with non-linear load Frequency stability on battery BYPASS Rated voltage [V] Frequency tolerance OVERALL SPECIFICATIONS Weight [kg] Dimension (WxDxH) [mm] Input cable Remote signals Volt-free contact (configurable) Remote controls EPO, bypass battery charge block...
Open the catalog to page 10NextEnergy UPS PowerShield3 Mail Server Ethernet Switch Ethernet NextEnergy UPS NetMan 208 board Modbus/TCP Manager SNMP Manager Ethernet Switch Ethernet SNMP Protocol The information in this document is subject to change without notice. Riello UPS assumes no responsibility for any errors that may appear in this document. Modbus/TCP Protocol RPS SpA - Riello Power Solutions - Member of the Riello Elettronica Group Viale Europa, 7 - 37045 Legnago (Verona) - ITALY - Tel: +39 0442 635811 www.riello-ups.com
Open the catalog to page 11All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Pass 10, 16, and 16-R
1 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Master MPS
8 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
Multi Sentry
5 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
Guard Tower
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages