MultiCom - Multi I/O e Multi Panel
8Pages

{{requestButtons}}

Catalog excerpts

MultiCom - Multi I/O e Multi Panel - 1

Connectivity ACCESSORIES NetMan 208 CARD - ETHERNET - SNMP The NetMan 208 network card allows UPS directly connected over LAN 10/100/1000 Mb connections to be managed using the main network communication protocols (TCP/IP, HTTP and SNMP). It is the ideal solution for the integration of UPS over Ethernet networks with Modbus/TCP or BACNET/IP protocols. It was developed to integrate UPS into medium-sized and large networks, to provide a high level of reliability in communication between the UPS and associated management systems. FEATURES • 32 bit RISC dual core processor; • Compatible with 10/100/1000 Mbps Ethernet and IPv4/6 networks; • Compatible with PowerShield3 and PowerNetGuard; • SNMP v1, v2 and v3 with RFC1628 for PowerNetGuard and NMS connection; • SNMP v1, v2 and v3 with RFC3433 for the management of environmental sensors; • HTTPS for UPS control via web browser; • SMTP for alarm notifications and UPS status updates via email; • Ldap and Active Directory integration for centralised authentication mechanism support; • Permits to initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disturbance to protected devices by UPS with migration systems such as VMware and vMotion™. NetMan 208 can monitor and manage UPS either inside or outside the data center. Can also measure power consumption to help calculate power usage effectiveness (PUE), the standard metric utilised for gauging Data Center power efficiency. • Modbus/TCP; • BACNET/IP; • Maximum expandability; • Events log and data management; • Wake-on-LAN management for starting computers via TCP/IP network; • Other standards: DHCP, DNS, RARP, FTP, NTP, ICMP, IGMP; • Management of environmental sensors; • Configurable via SSH sessions and web; • Firmware upgradeable via web browser; • Configurable firewall. Environmental sensor FOR NETMAN 208 The NetMan 208 environmental sensors is able to monitor and record environmental conditions, as well as activities in protected areas and the area where the UPS is installed. The environmental sensors allow management and control to be extended to cover the area around the UPS, monitoring the temperature and humidity and driving cooling fans or locks. Values are provided via Internet, SNMP and via PowerShield3 software. PowerShield3 can be used to manage sensor operating states in order to send messages. Refer to PowerShield3 software documentation for further information. NetMan 208 can manage up to 6 separate sensors. Environmental sensors are quick to install thanks to their small footprint and they do not require a separate external power supply. Thanks to the self-learning sensors, configuration is also rapid and intuitive. Available sensor: -55 +60 °C Temperature 0-100% humidity Sensor and I/O digital 0-12

Open the catalog to page 1
MultiCom - Multi I/O e Multi Panel - 2

MultiCom 302 CARD - MODBUS/JBUS INTERFACE The MultiCom 302 protocol converter allows UPS monitoring using the MODBUS/ JBUS protocol over RS232 or RS485 serial lines. In addition, it also manages a second independent RS232 serial line that can be used to connect to other devices such as the PLC or a PC running PowerShield3 software. FEATURES • Port configuration for MODBUS/JBUS as RS232 or RS485; • Management of two independent serial lines; • Suitable for integration with the main BMS management programs. MultiCom 352 CARD - INTERFACE DUPLEXER The MultiCom 352 serial duplicator is an...

Open the catalog to page 2
MultiCom - Multi I/O e Multi Panel - 3

MultiCom 392 SLOT EXPANDER NETWORK CARD MultiCom 392 is a communications card that provides 8 configurable dry contact outputs and up to 4 inputs to assist with monitoring and control of the UPS. Device is compatible with a broad range of Riello UPS models, including Multi Power, Multi Sentry, Sentryum and our Central Supply Systems (CSS). MultiCom 411 PROFIBUS PROTOCOL CONVERTER The MultiCom 411 connects a Riello UPS to a Profibus DP Network. In industrial environments, the Gateway integrates UPS management and monitoring into a control system. The Gateway uses the field bus design, one of...

Open the catalog to page 3
MultiCom - Multi I/O e Multi Panel - 4

Multi Panel REMOTE DISPLAY INTERFACE The Multi Panel is a remote monitoring device that can provide a detailed UPS status overview in real time. This device is able to display mains power, output and battery readings as well as UPS operating states. The high visibility graphic display supports English, Italian, German, French, Spanish, Russian, Chinese and many other languages. It has 3 independent serial ports, one of which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The other independent serial lines can be used to connect devices such...

Open the catalog to page 4
MultiCom - Multi I/O e Multi Panel - 5

CONNECTIVITY EXAMPLES Index of configurations Connecting a UPS to other devices, sensors, computers and other specific devices, means on the one hand allowing the user to monitor UPS operating parameters and prevent critical situations and on the other hand provides the UPS with input parameters from the working environment. By processing these parameters the UPS is able to activate/ deactivate itself, communicate its status and much more. This brief overview summarises some of the basic connectivity configurations, grouped according to the end purpose and situation surrounding each case. •...

Open the catalog to page 5
MultiCom - Multi I/O e Multi Panel - 6

DISTRIBUTED CONNECTION (MULTIPOINT) Connection with more than 1 UPS. The FULL version of PowerShield3 software is required as well as a NetMan 208 communication board on each UPS. NetMan 208 board Firewall Switch Remote computer connected via web Local computer Local computer that controls the UPS (8) via USB or RS232 and UPS (1) via LAN and Ethernet USB or RS232 Ethernet CONNECTION FOR UPS IN PARALLEL SETUP The FULL version of PowerShield3 software should be used for managing setups with several UPS installed in parallel and each UPS must have a NetMan 208 board installed. UPS in parallel...

Open the catalog to page 6
MultiCom - Multi I/O e Multi Panel - 7

CONNECTION WITH SEVERAL SYSTEMS IN PARALLEL AND STS The FULL version of PowerShield3 software should be used for managing setups with several UPS installed in parallel and each UPS must have a NetMan 208 board installed. UPS arranged in parallel connected to an STS channel Remote computer connected via web, running PowerShield3 software version FULL UPS arranged in parallel connected to an STS channel Firewall STS connected to load UGS Local computer with PowerShield3 software version FULL UGS management of parallel setup Ethernet World Wide Web 6 Power connection FIELD BUS CONNECTION OVER...

Open the catalog to page 7

All RIELLO UPS catalogs and technical brochures

  1. Master FC400

    2 Pages

  2. iDialog

    2 Pages

  3. iDialog Rack

    2 Pages

  4. Net Power

    2 Pages

  5. Sentinel Pro

    4 Pages

  6. Multi Switch

    2 Pages

  7. Powershiled3

    1 Pages

  8. iPlug

    3 Pages

  9. Master MPS

    8 Pages

  10. Vision

    3 Pages

  11. Vision Rack

    3 Pages

  12. Vision Dual

    4 Pages

  13. Sentryum

    11 Pages

  14. NextEnergy NXE

    11 Pages

  15. Multi Sentry

    5 Pages

  16. Multi Power2

    8 Pages

  17. Guard Tower

    4 Pages

  18. Sentryum S3U

    4 Pages

  19. Master HP UL

    4 Pages

Archived catalogs