Multi Switch - 1

Master Switch STS SINGLE-PHASE Static Transfer Switch Plug & Play installation HIGHLIGHTS • Operating flexibility • Load protection • Complete diagnostics • Hot Swap function Master Switch Single-phase (MMS) is part of the Master Switch range and offers solutions suitable for protecting singlephase loads with different power ratings. MMS is available in three sizes: 32, 63 and 120 A and is therefore able to satisfy various requirements for the protection of single-phase loads. FLEXIBILITY OF USE All MMS versions are designed with criteria that facilitate on-site installation as well as diagnostics, control and maintenance operations. All models are equipped with a manual bypass and the hot swap function allows for rapid corrective interventions by non-specialised personnel in the event of faults. LOAD PROTECTION With MMS transfer switch loads are protected against critical environmental situations and mains power interference. Microprocessor control and the use of thyristor static switches ensure continuous monitoring of the power supply sources and reduced switching times between the two sources in the event of a fault. The constant monitoring of the output current allows for the rapid identification of any short circuit currents in the consumers, preventing short circuits from propagating to other loads. MMS is equipped with thermal-magnetic protection for the two sources, ensuring rapid intervention in the event of faults and integrated backfeed protection. MMS ensures switching times between the two power sources of less that a quarter of a cycle, both in the event of manual switching and in the event automatic switching triggered by a fault in the power source. COMPLETE DIAGNOSTICS All MMS versions are equipped with 32-character LCD displays and control panels with multi-function keys. This allows for rapid and intuitive monitoring of supply readings, switch status and environmental conditions. MMS is equipped with three standard programmable dry contacts, an input for emergency shutdown, a RS232 serial connection and a slot for housing the expansion board, thus ensuring complete availability of interface solutions for remote control and monito

Open the catalog to page 1
Multi Switch - 2

R.E.P.O. CONNECTORS WITH DRY CONTACTS ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 411 MULTICOM 421 MAINTENANCE BYPASS COMMUNICATIONS INTERFACE SLOT INPUT SWITCH (SWIN) S1 INPUT SWITCH (SWIN) S2 IN/OUT TERMINAL BOARD Remove the screws placed on left/right side and extract the unit Replace the faulty unit with a new one Fix the parts, follows start up procedure and return back from manual bypass All operations are carefully described on operating manual. OPERATING SPECIFICATIONS Nominal Current [A] Transfer type “Break Before Make” (no overlapping sources) Available transfer...

Open the catalog to page 2

All RIELLO UPS catalogs and technical brochures

  1. Master FC400

    2 Pages

  2. iDialog

    2 Pages

  3. iDialog Rack

    2 Pages

  4. Net Power

    2 Pages

  5. Sentinel Pro

    4 Pages

  6. Powershiled3

    1 Pages

  7. iPlug

    3 Pages

  8. Master MPS

    8 Pages

  9. Vision

    3 Pages

  10. Vision Rack

    3 Pages

  11. Vision Dual

    4 Pages

  12. Sentryum

    11 Pages

  13. NextEnergy NXE

    11 Pages

  14. Multi Sentry

    5 Pages

  15. Multi Power2

    8 Pages

  16. Guard Tower

    4 Pages

  17. Sentryum S3U

    4 Pages

  18. Master HP UL

    4 Pages

Archived catalogs