Catalog excerpts
Multi Sentry Energy Share SmartGrid ready HIGHLIGHTS • Range 160-200 kVA • High efficiency up to 96.2% • Zero impact • Flexibility of use • Advanced communications The Multi Sentry series is ideal for protecting Data Centers and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 160-200 kVA models with three-phase input and output and ON LINE double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3). Multi Sentry is designed and built using state-of-the-art technology and components. It has a fully controlled IGBT rectifier to minimise the impact on the grid. It is controlled by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems and optimised energy savings. ZERO IMPACT SOURCE Multi Sentry solves installation problems in systems where the power supply has limited power available, where the UPS is supported by a generator or where there are compatibility problems with loads that generate harmonic currents; Multi Sentry has a zero impact on its power source, whether this is the mains power supply or a generator: • Input current distortion up to <2.5%; • Input power factor 0.99; • Power walk-in function that ensures progressive rectifier start up; • Start up delay function, to restart the rectifiers when mains po
Open the catalog to page 1HIGH EFFICIENCY State-of-the-art three-level NPC inverters are used across the power range (160-200 kVA) to achieve an operating efficiency of 96.2%. This technology halves (50%) the energy dissipated in a year by traditional UPS, with an efficiency level of 92%. Its exceptional performance makes it possible to recover the capital investment cost in less than three years of operation. if there are several UPS in the system. In addition, Multi Sentry plays a filtering and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and reactive...
Open the catalog to page 2• More active power than a traditional UPS, guaranteeing a greater margin when sizing UPS for potential future load increases; • Smart ventilation principle on MST 160200 manages the number of operating fans and their speed according to room temperature and load level. This preserves the life span of the fans and at the same time we reduce noise level and overall power consumption for unnecessary UPS ventilation. FLEXIBILITY With its flexible configuration, performance, accessories and options, Multi Sentry is suitable for use in a wide range of applications: • Suitable for powering...
Open the catalog to page 3OPTIONS MULTICOM 411 MULTICOM 421 MULTI I/O MULTIPANEL MBB 400 A 4P SOFTWARE PowerShield3 PowerNetGuard ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 372 MULTICOM 384 Programmable relay board MULTICOM 392 IP rating IP30/IP31 Top cable entry Eyebolts kit PRODUCT ACCESSORIES Battery temperature sensor Parallel Kit Powerful battery charger BTC 1900 480V BB V6 3T BTC 1900 480V BB V7 3T Not available for MST 160-200 (when connected individually) According with battery cabinet fuse associated. MST 160-200 (rear) PARALLEL SLOT CONNECTORS R.E.P.O. - USB RS232 COMMUNICATIONS INTERFACE...
Open the catalog to page 4INPUT Rated voltage [V] Power factor @ full load Current distortion BYPASS Rated voltage [V] Frequency tolerance Bypass overload Power factor Static variation Dynamic variation Crest factor [lpeack/lrms] Voltage distortion ≤1% with resistive linear load / ≤3% with non-linear load Frequency stability during battery operation BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/Supercaps Recharge time OVERALL SPECIFICATIONS Weight without batteries [kg] 3 slots for communications interface / USB / RS232 Ambient temperature for the UPS Recommended temperature for battery life Range of relative humidity...
Open the catalog to page 5All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Pass 10, 16, and 16-R
1 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Master MPS
8 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
NextEnergy NXE
11 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
Guard Tower
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages