Catalog excerpts
Manual Transfer Switch Multi Pass 10, 16 and 16-R The Multi Pass manual bypass cuts out UPS in the event of a malfunction or fault. Multi Pass ensures that the connected equipment is automatically switched to mains power if a UPS is switched off or goes into blocked status. Multi Pass is available for rack or wall installations (box). FEATURES • 16 A rack version; • 10 A and 16 A wall mounted version; • Standard backfeed protection; • Multi Pass permits that the connected consumers are manually switched to mains power before a UPS is switched off or before make maintenance. ; • Mains power present LED indicator; • Available with different socket standards; (IEC, British socket, terminal boards). MBB 100 A 2P, MBB 125 A 4P and MBB 400 A 4P MAINTENANCE BYPASS Riello UPS offers several maintenance bypass solutions with two poles and four poles suitable for single and three-phase applications. These devices are equipped with three switches to completely isolate the UPS in case of maintenance needs, keeping, at the same time, the load supplied by the mains without any interruption. All the operations are done safely, thanks to a dedicated ausxiliary contact which provides the status of the MBB to the UPS, avoiding any simultaneous supply from the manual bypass and inverter. Riello UPS offers a wide range of external bypasses and static switches for UPS up to 800 kVA and for parallelm systems up to 6.4 MVA. The information in this document is subject to change without notice. Riello UPS assumes no responsibility for any errors that may appear in this document. MAINTENANCE BYPASS RPS SpA - Riello Power Solutions - Member of the Riello Elettronica Group Viale Europa, 7 - 37045 Legnago (Verona) - ITALY - Tel: +39 0442 635811 www.riell
Open the catalog to page 1All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Master MPS
8 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
NextEnergy NXE
11 Pages
-
Multi Sentry
5 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
Guard Tower
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages