Catalog excerpts
Master Switch STS THREE-PHASE Static Transfer Switch Service 1st start HIGHLIGHTS • High reliability • Hot Replacement function • 3 or 4 poles version • Advanced communications Installing a Master Switch static transfer switch provides additional resilience and protection from the disruption that can be caused by the failure of a single power source. The result is the absolute protection of industrial utilities and critical information technology against power supply and load faults. OPERATING PRINCIPLE Master Switch guarantees a source of redundant power, allowing the load to be switched between to alternative and independent power sources. Switching can be automatic (when a supply source falls outside of acceptable tolerances) or manually done by an operator from the front panel or remotely. PROTECTION AGAINST POWER SUPPLY FAULTS If one of the two power sources falls outside tolerance levels, Master Switch will transfer the consumers to the second power source (switching is instantaneous if the two sources are in phase). PROTECTION AGAINST ENVIRONMENTAL DISTURBANCES In the event of an overload, the user can decide the level of intervention of the internal protection devices in order to block the power supply. In the extreme case of a downstream short circuit, Master Switch disconnects the load in order to avoid jeopardising the operation of the other loads (i.e. in the event of poor selectivity of the protection devi
Open the catalog to page 1TOTAL MICROPROCESSOR CONTROL Microprocessor control logic ensures: • ast and safe switching between power F sources; • onitoring of all parameters via LCD M display; • onstant monitoring of SCR operation C • dvanced remote diagnostics (RS232 and A TCP/IP). REDUNDANT DESIGN Power is supplied to the internal logic by two physically separate supply circuits that are fully independent and that can be replaced in “hot replacement” mode without causing power supply interruptions to the load. In the event that the power supplied by both sources fails, full system operation is guaranteed by the...
Open the catalog to page 2MASTER SWITCH IN REDUNDANT MODE The secondary power source [AS], although highly reliable, only powers the load in the event of a failure with the priority power source [PS], ensuring maximum redundancy and power quality to the loads. MASTER SWITCH IN CROSS FEEDING MODE The two sources power critical loads using Master Switches configured to selected one of the two power sources as the priority source [PS]. In case of a failure in one of two sources, the other will be able to supply power to all the loads connected to the system. MASTER SWITCH IN BACK-UP MODE Independent separate lines...
Open the catalog to page 3OPERATING SPECIFICATIONS Nominal Current [A] Transfer type “Break Before Make” (no overlapping sources) Available transfer methods Automatic / Manual / Remote INPUT Rated voltage - sources S1/S2 [V] Switched input phases 3 ph+N (four poles version) - 3 ph (three poles version) Input frequency tolerance range Distribution compatibility OVERALL SPECIFICATIONS Weight [kg] three poles version Weight [kg] four poles version Dimensions (WxDxH) [mm] Communications 685x580x1770 RS232 / Relay contacts port Ambient temperature Range of relative humidity Colour Noise level at 1 m [dBA ±2] IP rating...
Open the catalog to page 4All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Pass 10, 16, and 16-R
1 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Master MPS
8 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
NextEnergy NXE
11 Pages
-
Multi Sentry
5 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
Guard Tower
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages