Catalog excerpts
Lithium compatible SmartGrid ready HIGHLIGHTS • EFFICIENCY CONTROL Mode (ECM) • Robust and reliable • Galvanic isolation • High overload capacity • Hot System Expansion (HSE) TOTAL PROTECTION The Master MPS series UPS provides maximum protection and power quality for mission critical loads, including data centers, industrial processes, telecommunications, security and electromedical systems. Master MPS is an ON LINE double conversion UPS classified as VFI-SS-111 (as set out by the IEC EN 62040-3 standard) with a transformer-based isolated inverter. The Master MPS range includes threephase input and single-phase output versions from 10 to 100 kVA and threephase input and output versions from 10 to 200 kVA. All versions are provided with a 6-pulse thyristor-based rectifier, with or without optional harmonic filters. A 12-pulse thyristor-based rectifier is available on request for the 60 and 80 kVA three-phase output versions with or without optional harmonic filters. EASY SOURCE Master MPS makes supplying the UPS from generator sets and MT/BT transformers simpler and more efficient, reducing power loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS. In addition to this, the progressive rectifier start up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generat
Open the catalog to page 1FLEXIBILITY Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for powering capacitive and inductive loads. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability, as well as providing the option to add new UPS without interruption to existing installation. BATTERY CARE SYSTEM: MAXIMUM BATTERY CARE Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source...
Open the catalog to page 2D= Twelve-pulse rectifier version HC= Version with 5th or 11th harmonic filter. Solution to ensure redundancy through synchronization of two power buses and improving STS operation. + Downstream fault discrimination Solution to ensure redundancy of the power supply even during maintenance. + High availability and redundancy Static Transfer SWITCH Load 3 Static Transfer SWITCH MPT 200 with open doors.
Open the catalog to page 3MPS (front) COMMUNICATION PORTS (R.E.P.O. - IN/OUT SIGNALS - RS 232) MAINS INPUT SWITCH (SWIN) BYPASS INPUT SWITCH (SWBYP) SLOTS FOR OPTIONAL ACCESSORY COMMUNICATION CARDS PARALLEL CARD [OPTIONAL] MANUAL BYPASS SWITCH (SWMB) UGS CARD [OPTIONAL] OUTPUT SWITCH (SWOUT) MULTI I/O CARD [OPTIONAL] ADDITIONAL COMMUNICATION PORTS (IN/OUT SIGNALS) [OPTIONAL] OPTIONS SOFTWARE PowerShield3 PowerNetGuard ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 411 MULTICOM 421 MULTI I/O MULTIPANEL MBB 100 A 2P MBB 125 A 4P MBB 400 A 4P PRODUCT ACCESSORIES Battery temperature sensor 5th or 11th...
Open the catalog to page 4BATTERY CABINET CABINETS WITH TOP ACCESS FOR CABLES SINGLE-PHASE ISOLATION TRANSFORMERS TBX ISO 10 M TBX ISO 80 M MPM 10-80 THREE-PHASE ISOLATION TRANSFORMERS
Open the catalog to page 5INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...
Open the catalog to page 6INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...
Open the catalog to page 7INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...
Open the catalog to page 8All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Pass 10, 16, and 16-R
1 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
NextEnergy NXE
11 Pages
-
Multi Sentry
5 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
Guard Tower
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages