Master MPS - 1

Lithium compatible SmartGrid ready HIGHLIGHTS • EFFICIENCY CONTROL Mode (ECM) • Robust and reliable • Galvanic isolation • High overload capacity • Hot System Expansion (HSE) TOTAL PROTECTION The Master MPS series UPS provides maximum protection and power quality for mission critical loads, including data centers, industrial processes, telecommunications, security and electromedical systems. Master MPS is an ON LINE double conversion UPS classified as VFI-SS-111 (as set out by the IEC EN 62040-3 standard) with a transformer-based isolated inverter. The Master MPS range includes threephase input and single-phase output versions from 10 to 100 kVA and threephase input and output versions from 10 to 200 kVA. All versions are provided with a 6-pulse thyristor-based rectifier, with or without optional harmonic filters. A 12-pulse thyristor-based rectifier is available on request for the 60 and 80 kVA three-phase output versions with or without optional harmonic filters. EASY SOURCE Master MPS makes supplying the UPS from generator sets and MT/BT transformers simpler and more efficient, reducing power loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS. In addition to this, the progressive rectifier start up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generat

Open the catalog to page 1
Master MPS - 2

FLEXIBILITY Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for powering capacitive and inductive loads. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability, as well as providing the option to add new UPS without interruption to existing installation. BATTERY CARE SYSTEM: MAXIMUM BATTERY CARE Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source...

Open the catalog to page 2
Master MPS - 3

D= Twelve-pulse rectifier version HC= Version with 5th or 11th harmonic filter. Solution to ensure redundancy through synchronization of two power buses and improving STS operation. + Downstream fault discrimination Solution to ensure redundancy of the power supply even during maintenance. + High availability and redundancy Static Transfer SWITCH Load 3 Static Transfer SWITCH MPT 200 with open doors.

Open the catalog to page 3
Master MPS - 4

MPS (front) COMMUNICATION PORTS (R.E.P.O. - IN/OUT SIGNALS - RS 232) MAINS INPUT SWITCH (SWIN) BYPASS INPUT SWITCH (SWBYP) SLOTS FOR OPTIONAL ACCESSORY COMMUNICATION CARDS PARALLEL CARD [OPTIONAL] MANUAL BYPASS SWITCH (SWMB) UGS CARD [OPTIONAL] OUTPUT SWITCH (SWOUT) MULTI I/O CARD [OPTIONAL] ADDITIONAL COMMUNICATION PORTS (IN/OUT SIGNALS) [OPTIONAL] OPTIONS SOFTWARE PowerShield3 PowerNetGuard ACCESSORIES NETMAN 208 MULTICOM 302 MULTICOM 352 MULTICOM 411 MULTICOM 421 MULTI I/O MULTIPANEL MBB 100 A 2P MBB 125 A 4P MBB 400 A 4P PRODUCT ACCESSORIES Battery temperature sensor 5th or 11th...

Open the catalog to page 4
Master MPS - 5

BATTERY CABINET CABINETS WITH TOP ACCESS FOR CABLES SINGLE-PHASE ISOLATION TRANSFORMERS TBX ISO 10 M TBX ISO 80 M MPM 10-80 THREE-PHASE ISOLATION TRANSFORMERS

Open the catalog to page 5
Master MPS - 6

INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...

Open the catalog to page 6
Master MPS - 7

INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...

Open the catalog to page 7
Master MPS - 8

INPUT Rated voltage [V] Soft start BYPASS Rated voltage [V] Permitted frequency tolerance Standard equipment provided ±2% (selectable from ±1% to ±5%) Backfeed protection; separable bypass line OUTPUT Nominal power [kVA] Static stability Dynamic stability EN 62040-3 class performance 1 non-linear load Voltage distortion <1% with linear load / <3% with non-linear load Crest factor [lpeack/lrms] Frequency stability on battery BATTERIES Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps Recharging method One level, Two level, Cyclic recharge (selectable) Battery arrangement (parallel systems) OVERALL...

Open the catalog to page 8

All RIELLO UPS catalogs and technical brochures

  1. Master FC400

    2 Pages

  2. iDialog

    2 Pages

  3. iDialog Rack

    2 Pages

  4. Net Power

    2 Pages

  5. Sentinel Pro

    4 Pages

  6. Multi Switch

    2 Pages

  7. Powershiled3

    1 Pages

  8. iPlug

    3 Pages

  9. Vision

    3 Pages

  10. Vision Rack

    3 Pages

  11. Vision Dual

    4 Pages

  12. Sentryum

    11 Pages

  13. NextEnergy NXE

    11 Pages

  14. Multi Sentry

    5 Pages

  15. Multi Power2

    8 Pages

  16. Master HP UL

    4 Pages

Archived catalogs

  1. Guard Tower

    4 Pages

  2. Sentryum S3U

    4 Pages