3:3 65-500 kVA HIGHLIGHTS • High efficiency • IGBT-based rectifier technology • Compact, reliable and robust • Galvanic isolation • High overload capacity The high levels of quality, reliability and energy savings offered by the Master HP range of UPS, has been extended to include a UL/CSA Listed, 480 V 60 Hz version with ratings from 65 kVA to 500 kVA. IT managers, facility managers, and CTOs are under increasing pressure to reduce downtime and assure that their critical loads are supplied with uninterrupted and high quality power. With this increasingly stringent requirement, Riello UPS has invested in power solutions that meet strict demands; a commitment resulting in the launch of the Master HP UL range. More than just an innovative and technologically-advanced UPS, it is a leap into the future of three-phase technology. With its double conversion ON LINE technology based entirely on IGBT and digital signal processors (DSP), the Master HP UL range ensures maximum critical load protection, with VFI SS 111 classification (Voltage and Frequency Independent) in accordance with IEC EN 62040-3. This range is designed using a new configuration that includes an IGBT sinusoidal input rectifier. Unique in its design, double conversion technology with galvanic isolated output guarantees a quality power supply that is completely protected from all electrical anomalies at the input. COMPLETE GALVANIC SEPARATION The Master HP UL UPS features an output isolation transformer on the inverter
Open the catalog to page 1as part of the inverter circuit inside the UPS cabinet, providing galvanic isolation between the load and the battery with improved versatility in system configuration, allowing: • Complete UPS output galvanic isolation for critical infrastructures from the battery DC power source; • Two truly separated supply inputs (utility and bypass), which can be taken from two different power sources (with different neutrals); this is particularly well suited for parallel systems in order to ensure selectivity between the two sources, improving the reliability of the entire installation; • No neutral input...
Open the catalog to page 2480 three-phase + N 45 / 65 >0.99 <3% THDi 0 - 100% in 125” (selectable) ±2% (selectable from ±1% to ±5% from front panel) Back Feed protection; separable bypass line INPUT Rated voltage [V] Frequency [Hz] Power factor Harmonic current distortion Soft start Frequency tolerance Standard equipment provided BATTERIES Type Ripple current Recharge voltage compensation OUTPUT Nominal power [kVA] Active power [kW] Number of phases Rated voltage [V] Static stability Dynamic stability Voltage distortion Crest factor [lpeack/lrms] Frequency stability on battery Frequency [Hz] Overload VRLA, Wet Cell, NiCd...
Open the catalog to page 3INPUT Rated voltage [V] Frequency [Hz] Power factor Harmonic current distortion Soft start Frequency tolerance Standard equipment provided BATTERIES Type Ripple current Recharge voltage compensation OUTPUT Nominal power [kVA] Active power [kW] Number of phases Rated voltage [V] Static stability Dynamic stability Voltage distortion Crest factor [lpeack/lrms] Frequency stability on battery Frequency [Hz] Overload 480 three-phase + N 45 - 65 > 0.99 <3% THDi 0 - 100% in 125’’ (selectable) ±2% (selectable from ±1% to ±5% from front panel) Back Feed protection; separable bypass line VRLA, Wet Cell,...
Open the catalog to page 44 Pages
6 Pages
4 Pages
8 Pages
8 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
5 Pages
8 Pages
2 Pages
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
8 Pages
3 Pages
3 Pages
4 Pages
6 Pages
9 Pages
11 Pages
11 Pages
5 Pages
4 Pages
210 Pages
4 Pages
4 Pages
60 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages