1. Catalogs
  2. RIELLO UPS
  3. Master HP FC UL

Master HP FC UL

Master HP FC UL

Master HP FC UL

Product catalog summary
Overview: The Master HP FC UL is a high-efficiency voltage and frequency converter designed for critical applications in the emergency e-medical industry and datacentre transport. It offers power ratings from 80 to 200 kVA with a 480 V - 60 Hz input and 400 V - 50 Hz output, certified as UL.
Key Features:
  • High efficiency with IGBT-based rectifier technology.
  • Output voltage of 400 V at 50 Hz with galvanic isolation.
  • High overload capacity and zero impact source with minimal input current distortion (<3%).
  • Battery Care System for optimized battery performance and extended life.
Technical Specifications:
  • Input: 480 V three-phase, frequency 45/65 Hz, power factor >0.99, harmonic current distortion <3%.
  • Output: Nominal power ranges from 80 to 200 kVA, active power from 72 to 180 kW, voltage distortion <1% with linear load.
  • Overload capacity: 110% for 60 min, 125% for 10 min, 150% for 1 min.
  • Operating temperature: 32 – 104 °F (0 – 40 °C), relative humidity <95% non-condensing.
Design and Installation:
  • Compact size and reduced weight for transformer-based FC.
  • Advanced supervision with a front panel graphic display for status updates and alarms.
  • Options for parallel configurations up to 8 units for redundancy or power parallel configurations.
Standards and Compliance:
  • Complies with UL Standard 1778 and IEC 62040-3 for VFI - SS - 111 classification.
  • Meets National Electrical Code (NFPA-70) and FCC Part 15 Subpart J class A standards.
Applications: Suitable for a wide range of applications including capacitive loads like blade servers, motor drivers, and other critical vertical applications.
Contact Information: The document provides contact details for Riello UPS subsidiaries worldwide, including locations in the USA, UK, Germany, France, Spain, Romania, Poland, Australia, Asia Pacific, China, India, and the Arabian Peninsula.
See more

Catalog excerpts

Master HP FC UL-1

^rielloups Master HP FC UL LISTED 80-200 kVA Voltage and Frequency Converter HIGHLIGHTS • High efficiency • IGBT-based rectifier technology • Output voltage: 400 V - 50 Hz • Galvanic isolation • High overload capacity The high levels of quality, reliability and energy savings offered by the Master HP range of UPS have been extended to include frequency converter 480 V - 60 Hz input /400 V - 50 Hz output certified as UL, with power ratings from 80 to 200 kVA. The typical application of such Frequency Converters is the power supply of the loads at 400 V, 50 Hz as for example imported from other countries. The FC units can work with or without battery. With its double conversion ON LINE technology based entirely on IGBT and digital signal processors (DSP), the Master HP FC UL range ensures maximum critical load protection, with VFI SS 111 classification (Voltage and Frequency Independent) in accordance with IEC EN 62040-3. This range is designed using a new configuration that includes an IGBT sinusoidal input rectifier. Unique in its design, double conversion technology with galvanic isolated output guarantees a quality power supply that is completely protected from all electrical anomalies at the input. COMPLETE GALVANIC SEPARATION Master HP FC UL feature an output isolation transformer (delta zig/zag type) on the inverter as part of the inverter circuit inside the FC cabinet, providing galvanic isolation between the load and the battery with improved versatility in system configuration, allowing: • Complete FC output galvanic isolation

 Open the catalog to page 1
Master HP FC UL-2

for critical infrastructures from the battery DC power source; • No neutral input connection is required at the rectifier input stage; • No effects to the FC output performance or reduced impact of the inverter power components whilst supplying specific loads; in addition the inverter transformer minimizes the impact of third harmonic disturbances, prevents the effects of energy back-feed into the inverter when supplying industrial load applications and can supply unbalanced loads. • High inverter short circuit current to clear faults which occur between phase and neutral on load side (up to...

 Open the catalog to page 2
Master HP FC UL-3

INPUT Rated voltage [V] Frequency [Hz] Power factor Harmonic current distortion Soft start Frequency tolerance BATTERIES Type Ripple current Recharge voltage compensation OUTPUT Nominal power [kVA] Active power [kW] Number of phases Rated voltage [V] Static stability Dynamic stability Voltage distortion Crest factor [lpeack/lrms] Frequency stability on battery Frequency [Hz] Overload INFO FOR INSTALLATION Weight [lbs/kg] Weight with TCE [lbs/kg] Dimensions (WxDxH) [inches/mm] Dimensions with TCE and Maintenance bypass (WxDxH) [inches/mm] Remote signals Remote controls Operating temperature Relative...

 Open the catalog to page 3
Master HP FC UL-4

RPS S.p.A. ITALY LEGNAGO (VR) Head Office ViaLe Europa, 7 37045 LEGNAGO (Verona) TeL +39 0442 635811 CORMANO (MI) Visit www.riello-ups.com/bases Sales Office for contact detaHs. Via SomaLia, 20 20032 CORMANO (MiLano) TeL +39 02 663271 USA RPS America, Inc. 8808 Beckett Rd West Chester, OH 45069 Tel +1-513-282-3777 UNITED KINGDOM RIELLO UPS Ltd. Unit 50 CLywedog Road North Wrexham Industrial Estate Wrexham LL13 9XN Tel +44 800 269 394 CONSTANT POWER SERVICES Ltd. RieLLo House, Works Road, Letchworth SG6 1AZ Hertfordshire TeL +44 330 1230125 GERMANY RIELLO UPS GmbH WiLheLm-Bergner-Str. 9b 21509...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.