Catalog excerpts
DIGITAL LIVING Guard Tower ONLINE • Transformer based • Small footprint • Power factor 1 • Maintenance bypass • Galvanic Isolation transformer • High quality output voltage Guard Tower is the ideal solution for protecting mission critical systems such as safety devices, telecommunications equipment and IT systems to ensure maximum power reliability. Guard Tower is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimised energy savings. The series includes 6-10 kVA/kW single/single-phase output models with ON LINE double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology and performance, Guard Tower is one of the best UPS available on the market today: output power factor 1 to Increase in efficiency of system and devices and reduce power system losses. Selectable ECO Mode functions; new custom diagnostics LCD display, RS232 and USB interfaces with PowerShield3 software, ESD input, interf
Open the catalog to page 1HIGH BATTERY RELIABILITY ADVANCED COMMUNICATIONS • Total microprocessor and DSP control. • Interruption-free static and manual bypass; • Specifications guaranteed up to 104 °F/40 °C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures). • Automatic and manual battery test. • Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life...
Open the catalog to page 2RS-232 COMMUNICATION PORT USB COMMUNICATION PORT EMERGENCY POWER OFF FUNCTION CONNECTOR (EPO CONNECTOR) COMMUNICATION CARD SLOT ACCESSORIES NETMAN 104 MULTICOM 184 Manual Bypass MBB 100 A PDU box (see images below) CHARGER FAN EXTERNAL BATTERY CONNECTOR (ONLY AVAILABLE FOR LONG-RUN MODEL) BATTERY CIRCUIT BREAKER MAINTENANCE BYPASS SWITCH INPUT CIRCUIT BREAKER PDU box top view ISOLATION TRANSFORMER FAN INPUT/OUTPUT TERMINAL BATTERY CABINET Dimensions [inches/mm]
Open the catalog to page 3INPUT Rated Power [VA] Current distortion BYPASS Voltage tolerance [V] Frequency selected (from ±0 to ±5 configurable) 240 plus neutral for a split of 120 / 120 or 230 plus neutral for a split 115 / 115 Number phases Crest factor [Ipeak/Irms] Voltage distortion with non linear load Voltage distortion with linear load BATTERIES Type VRLA AGM lead, maintenance-free Typical recharge time ENVIRONMENTAL Maximum altitute [ft/m] USB / DB9 with RS232 and contacts / Slot for communication interface Safety compliance CFR 47 FCC Part 15, Subpart B, Class A 2016 Accessories provided Power cable, serial...
Open the catalog to page 4All RIELLO UPS catalogs and technical brochures
-
Sentinel Rack
4 Pages
-
PowerNetGuard
1 Pages
-
Master FC400
2 Pages
-
iDialog
2 Pages
-
iDialog Rack
2 Pages
-
Net Power
2 Pages
-
Sentinel Pro
4 Pages
-
Sentinel Dual SDH
4 Pages
-
Sentinel Dual SDU
5 Pages
-
Master HP & Master HE
8 Pages
-
Master Industrial
2 Pages
-
Multi Pass 10, 16, and 16-R
1 Pages
-
Multi Socket PDU
2 Pages
-
Multi Switch
2 Pages
-
Multi Switch ATS
3 Pages
-
SuperCaps UPS
4 Pages
-
Powershiled3
1 Pages
-
iPlug
3 Pages
-
Master MPS
8 Pages
-
Vision
3 Pages
-
Vision Rack
3 Pages
-
Vision Dual
4 Pages
-
Central Supply Systems CSS
6 Pages
-
Multi Power 15-294 kVA
9 Pages
-
Sentryum
11 Pages
-
NextEnergy NXE
11 Pages
-
Multi Sentry
5 Pages
-
Sentryum Rack
4 Pages
-
General Catalogue 2023
210 Pages
-
Multi Power2
8 Pages
-
Master HP FC UL
4 Pages
-
Master HP UL
4 Pages
Archived catalogs
-
Sentinel Tower STW
4 Pages
-
North America Catalogue
60 Pages
-
Sentryum S3U
4 Pages
-
Sentinel RT 6-10 kVA
4 Pages
-
Sentinel RT 1-3 kVA
4 Pages
-
Multi Guard Industrial
4 Pages
-
Master Static By-pass
4 Pages