Catalog excerpts
5.4 MHz pulse repetition rate, and 750 lines per second resulting in up to 13,000 pts/m2 in approximately 3 m range at 80 km/h platform speed The RIEGL VMX-RAIL is a fully integrated Mobile Laser Scanning System for track mapping and clearance surveying. The triple scanner system design allows for utmost efficient capturing of dense, accurate, and feature-rich data. Take advantage of the VMX-RAIL for • accurate surveying in challenging environments • reliable capturing of railway infrastructure, topography, and vegetation • platform speed up to 130 km/h for operation during regular rail schedules • reduction of scan shadows by triple scanner system design • flexible camera options to complement scan data with high resolution imaging • data export to Third-Party Rail-Processing Software Packages Triple Scanner Mobile Mapping System Specifically Designed for Rail Application Typical Applications • Rapid and Safe Data Capture with Minimal Disruption to Network Schedules • Rail Infrastructure Asset Management • As-Built Surveying • Track and Infrastructure Monitoring • Clash Detection Simulation and Clearance Analysis • Railway Planning and E
Open the catalog to page 1RIEGL VMX-RAIL VMX-RAIL Key Features • rugged measuring-head for reliable long-term operation in harsh environments • equipped with 3 VUX-1HA22 High Accuracy Laser Scanners • optimized scanner orientation to increase the field of view and to minimize scan shadows • unique crossed point cloud pattern along 360 degree of the clearance profile for improved feature extraction and small object detection • 5.4 MHz pulse repetition rate and 750 lines per second resulting in up to 13,000 pts/m2 in approximately 3 m range at 80 km/h platform speed RIEGL VMX-RAIL scan data State-of-the-Art Track...
Open the catalog to page 2at a glance RIEGL VMX-RAIL RIEGL VMX-RAIL Components and Setup GNSS antenna protective housing for enhanced scan head protection (3x) RIEGL VUX-1HA22 laser scanner (3x) VMX-RAIL-MH Measuring Head thermo-electronic elements and forced-air cooling RIEGL cameras (optional) main electronics unit: IMU/GNSS electronics, distribution of power supply and synchronization signals, camera control unit, control electronics for thermo-electric elements lifting point shock absorbers RIEGL VMX-RAIL System Block Diagram VMX-RAIL-RM Roof Mount RIEGL VMX-RAIL System Components • VMX-RAIL-MH: temperature...
Open the catalog to page 3at a glance RIEGL VMX-RAIL RIEGL VMX-RAIL VMX-RAIL-MH Measuring Head VMX-RAIL-RM Roof Mount VMX-RAIL-CR Control Rack VMX-RAIL-MC Main Cable 654 x 1456 x 406 mm 837 x 1340 x 412 mm min. 500 mm stack space requirement in a 19” rack tailored cable length RIEGL VMX-RAIL-CR • 19 inch rack based control unit for fixed installation in a rail car • The VMX-RAIL Main Cable is connected with a Harting® connector to the rear of the VMX-RAIL Control Rack. RIEGL VMX-RAIL-CM Control Module * 4 rack units AC/DC power supply * 1 rack unit scan and image data acquisition computer * 4 rack units...
Open the catalog to page 4RIEGL VMX-RAIL RIEGL VMX-RAIL Technical Data 475m max. measurement range optional digital camera pulse repetition rate (peak) online waveform processing multiple target capability eye safe operation at Laser Class 1 VMX-RAIL Scanner Performance Laser Class 1 (Class 1 Laser Product according to IEC 60825-1:2014) Laser Class Max. Range, Target Reflectivity ≥ 10% 2) 3) Effective Measurement Rate Max. Range, Target Reflectivity ≥ 80% Max. Number of Targets per Pulse Minimum Range Scan Speed (selectable) 1) Rounded values, selectable by measurement program. 2) Typical values for average...
Open the catalog to page 5RIEGL VMX-RAIL at a glance Data Interfaces VMX-RAIL-MH 6x multi-purpose ports supporting complementary camera systems and additional devices, each with - trigger pulse - precise time stamping of exposure pulse - NMEA data - PPS - LAN 1GigE - power 24 V DC, max. 30 W VMX-RAIL-CR 1x DMI input (for distance measuring indicator; odometer) 1x NAV RS-232 (COM port for IMU/GNSS for RTK, SBAS) 1x NAV RS-232 (COM output for synchronization of external device) 1x AUX power supply output (+28 V DC, max 30 W) 1x rack-based industrial PC with standard interfaces: -) LAN, 1000 Mbit/sec (e.g. to connect...
Open the catalog to page 6All RIEGL LMS catalogs and technical brochures
-
RIEGL VQ-580 II-S
8 Pages
-
RIEGL VQ-680 OEM
8 Pages
-
RIEGL VQ-680
8 Pages
-
RIEGL VQ-860-G
6 Pages
-
RIEGL VZ-600i
8 Pages
-
RIEGL VQ-1460
10 Pages
-
RIEGL VQ-1260
10 Pages
-
RIEGL VQ-1560 III-S
10 Pages
-
RIEGL VZ-4000i-25
8 Pages
-
RIEGL VQ-840-GL
6 Pages
-
RIEGL VQ-840-G
6 Pages
-
RIEGL VQ-840-GE
6 Pages
-
RIEGL VPX-1
2 Pages
-
RiLOC-F - Preliminary
1 Pages
-
RIEGL VMX-2HA
8 Pages
-
RIEGL RiLOC-E
1 Pages
-
RiMINING
4 Pages
-
RIEGL VUX-180-24
6 Pages
-
RIEGL VUX-240-24
6 Pages
-
VUX-160²³
6 Pages
-
RIEGL VUX-120²³
8 Pages
-
RIEGL miniVUX-3UAV
6 Pages
-
RIEGL V-Line UB23
2 Pages
-
RIEGL VMY-2
8 Pages
-
RIEGL VMQ -1HA
6 Pages
-
RIEGL Mobile Mapping Systems
1 Pages
-
RIEGL BLS Overview
1 Pages
-
LIS TreeAnalyzer Plugin
2 Pages
-
RIEGL VZ-2000i
10 Pages
-
RIEGL VZ-400i
10 Pages
-
RIEGL Monitoring Apps
2 Pages
-
RIEGL VQX-1 Wing Pod
4 Pages
-
LIS GeoTec Plugin
2 Pages
-
RIEGL VQ-480 II
6 Pages
-
RIEGL VMY-1
4 Pages
-
RIEGL VMR
4 Pages
-
RDBLib
2 Pages
-
RiSOLVE
4 Pages
-
RIEGL VQ-1560 II-S
10 Pages
-
RIEGL VQ-780 II-S
8 Pages
-
RIEGL VQ-780 II
8 Pages
-
RIEGL LD05e-A30-PH67
5 Pages
-
RIEGL LD05-A10GF
10 Pages
-
LD05e-A10, LD05e-A30
4 Pages
-
RIEGL VUX-240
6 Pages
-
RIEGL VQ-580 II
6 Pages
-
RiPROCESS
4 Pages
-
RIEGL VQX-2 Helicopter Pod
4 Pages
-
RIEGL ULS Overview
1 Pages
-
RIEGL ALS Overview
1 Pages
-
RIEGL VMX-2HA-BC
2 Pages
-
RIEGL PH-VUX
2 Pages
-
RIEGL Topo-Bathymetry
4 Pages
-
RIEGL miniVUX-SYS
4 Pages
-
RIEGL VUX-1UAV-22
6 Pages
-
RIEGL VUX-1HA-22
4 Pages
-
RIEGL VUX-1LR-22
6 Pages
-
RIEGL V-Line CB23
2 Pages
-
RIEGL UAV Sensors & Systems
2 Pages
-
RiSCAN PRO
4 Pages
-
RIEGL VUX-SYS
4 Pages
-
RIEGL VZ-400i
2 Pages
-
RIEGL miniVUX-1UAV
4 Pages
-
RiVLib
4 Pages
-
RiACQUIRE
4 Pages
-
RiUNITE
4 Pages
-
RIEGL VQ-1560i-DW
10 Pages
-
RIEGL VMZ
4 Pages
-
RIEGL VZ-6000
6 Pages
-
RIEGL VZ-4000
6 Pages
-
RiPANO
4 Pages
-
RIEGL DR1560i
2 Pages
-
RiHYDRO
2 Pages
-
RIEGL LD05e-HT
4 Pages
-
RIEGL LD05-HTGF
13 Pages
-
RIEGL VZ-2000i
2 Pages
Archived catalogs
-
RIEGL miniVUX-1LR
4 Pages
-
RIEGL miniVUX-2UAV
4 Pages
-
RIEGL LD05-A80
5 Pages