![RIEGL LMS - logo](https://img.directindustry.com/images_di/logo-p/L15822.gif)
![video corpo](https://img.directindustry.com/media/ps/images/common/stand/video-icon.gif)
Catalog excerpts
![RIEGL V-Line CB23 - 1](https://img.directindustry.com/pdf/repository_di/15822/riegl-v-line-cb23-1031619_1m.jpg)
Communication Box for RIEGL V-Line Laser Scanners RIEGL scanners are often used in fixed installations in remote environments. For this application, a stable hardware power supply and remote operation of the system are mandatory. In the unlikely event of any hardware/ firmware failure, the system shall automatically reboot and continue with the specified data acquisition tasks on the scanner. To enable a stable and seamless remote 24/7 operation of RIEGL V-Line scanners, RIEGL offers the V-Line CB The housing of the CB is designed for usage in 23. 23 harsh environment and consists of a number of hardware components. Key Features » enables stable 24/7 remote system operation » operation within a wide temperature range (-20° to +50° C) » compact and water proved housing » high accurate environmental data by external sensor » IP64 for usage in harsh environment » one Power IN connector to support all connected devices (including the scanner) Hardware Components, Functionality & Technical Data Watchdog RIEGL V-Line UB 23 Switch Circuit Breaker LTE-Router LAN (any second device) LAN (scanner) Power IN (12-30 voltage) Power Supply Input Voltage Power Consumption (max.) without scanner Thermoelectric cooler inactive 40 W Thermoelectric cooler active 90 W Main Dimensions (LxBxH) Protection Class Temperature Range Storage / Operation Low Temperature Operation -10°C up to +50°C / 0°C up to +50°C -20°C: continuous operation if the instrument is powered on while internal temperature is at or above 0°C and still air Copyright RIEGL Laser Measurement Systems GmbH © 2023– All rights reserved. Use of this data sheet other than for personal purposes requires RIEGL’s written consent. This data sheet is compiled with care. However, errors cannot be fully excluded and alternations might be necessary. ext. sensor for environmental data
Open the catalog to page 1![RIEGL V-Line CB23 - 2](https://img.directindustry.com/pdf/repository_di/15822/riegl-v-line-cb23-1031619_2m.jpg)
USB mass storage device switched power supply Watchdog RIEGL V-Line UB23 Circuit Breaker Legend: power supply + power supply + (switched by Watchdog relay: CH1) power supply + (switched by Watchdog relay: CH2) TCP/IP sensor, antenna cables MOBILE MAIN internal environmental sensor dehumidifier unit external environmental sensor The integrated sim card of a local network operator enables LTE Internet connection. The pre-installed VPN connection protects the system from unauthorized access and enables remote access and configuration of all integrated hardware components. All necessary TCP/IP...
Open the catalog to page 2All RIEGL LMS catalogs and technical brochures
-
RIEGL VQ-580 II-S
8 Pages
-
RIEGL VQ-680 OEM
8 Pages
-
RIEGL VQ-680
8 Pages
-
RIEGL VQ-860-G
6 Pages
-
RIEGL VZ-600i
8 Pages
-
RIEGL VQ-1460
10 Pages
-
RIEGL VQ-1260
10 Pages
-
RIEGL VQ-1560 III-S
10 Pages
-
RIEGL VZ-4000i-25
8 Pages
-
RIEGL VQ-840-GL
6 Pages
-
RIEGL VQ-840-G
6 Pages
-
RIEGL VQ-840-GE
6 Pages
-
RIEGL VPX-1
2 Pages
-
RiLOC-F - Preliminary
1 Pages
-
RIEGL VMX-2HA
8 Pages
-
RIEGL RiLOC-E
1 Pages
-
RiMINING
4 Pages
-
RIEGL VUX-180-24
6 Pages
-
RIEGL VUX-240-24
6 Pages
-
VUX-160²³
6 Pages
-
RIEGL VUX-120²³
8 Pages
-
RIEGL miniVUX-3UAV
6 Pages
-
RIEGL V-Line UB23
2 Pages
-
RIEGL VMY-2
8 Pages
-
RIEGL VMQ -1HA
6 Pages
-
RIEGL Mobile Mapping Systems
1 Pages
-
RIEGL BLS Overview
1 Pages
-
LIS TreeAnalyzer Plugin
2 Pages
-
RIEGL VZ-2000i
10 Pages
-
RIEGL VZ-400i
10 Pages
-
RIEGL Monitoring Apps
2 Pages
-
RIEGL VMX-RAIL
6 Pages
-
RIEGL VQX-1 Wing Pod
4 Pages
-
LIS GeoTec Plugin
2 Pages
-
RIEGL VQ-480 II
6 Pages
-
RIEGL VMY-1
4 Pages
-
RIEGL VMR
4 Pages
-
RDBLib
2 Pages
-
RiSOLVE
4 Pages
-
RIEGL VQ-1560 II-S
10 Pages
-
RIEGL VQ-780 II-S
8 Pages
-
RIEGL VQ-780 II
8 Pages
-
RIEGL LD05e-A30-PH67
5 Pages
-
RIEGL LD05-A10GF
10 Pages
-
LD05e-A10, LD05e-A30
4 Pages
-
RIEGL VUX-240
6 Pages
-
RIEGL VQ-580 II
6 Pages
-
RiPROCESS
4 Pages
-
RIEGL VQX-2 Helicopter Pod
4 Pages
-
RIEGL ULS Overview
1 Pages
-
RIEGL ALS Overview
1 Pages
-
RIEGL VMX-2HA-BC
2 Pages
-
RIEGL PH-VUX
2 Pages
-
RIEGL Topo-Bathymetry
4 Pages
-
RIEGL miniVUX-SYS
4 Pages
-
RIEGL VUX-1UAV-22
6 Pages
-
RIEGL VUX-1HA-22
4 Pages
-
RIEGL VUX-1LR-22
6 Pages
-
RIEGL UAV Sensors & Systems
2 Pages
-
RiSCAN PRO
4 Pages
-
RIEGL VUX-SYS
4 Pages
-
RIEGL VZ-400i
2 Pages
-
RIEGL miniVUX-1UAV
4 Pages
-
RiVLib
4 Pages
-
RiACQUIRE
4 Pages
-
RiUNITE
4 Pages
-
RIEGL VQ-1560i-DW
10 Pages
-
RIEGL VMZ
4 Pages
-
RIEGL VZ-6000
6 Pages
-
RIEGL VZ-4000
6 Pages
-
RiPANO
4 Pages
-
RIEGL DR1560i
2 Pages
-
RiHYDRO
2 Pages
-
RIEGL LD05e-HT
4 Pages
-
RIEGL LD05-HTGF
13 Pages
-
RIEGL VZ-2000i
2 Pages
Archived catalogs
-
RIEGL miniVUX-1LR
4 Pages
-
RIEGL miniVUX-2UAV
4 Pages
-
RIEGL LD05-A80
5 Pages