1. Catalogs
  2. RIEGL LMS
  3. RIEGL LD05-HTGF

RIEGL LD05-HTGF
1 /13Pages

RIEGL LD05-HTGF

RIEGL LD05-HTGF
1 /13Pages

Catalog excerpts

RIEGL LD05-HTGF-1

The RIEGL LD05-HTGF is a laser distance meter based on precise time-of-flight laser range measurement especially suited for demanding applications under critical environmental conditions, i.e. high ambient temperature or hazardous environment. It is additionally optimized for very high target temperatures. It uses state-of-the-art digital signal processing to enable precise distance measurement for complex multi-target situations even under bad visibility conditions. Digitizing the echo signal and subsequent analysis enables multi-target distance measurements. The measuring system consists of an optical head meeting the requirements of the relevant application and a separate electronics box, connected by a duplex glass-fiber cable of variable length with connectors on both sides. • Electronics unit and measuring head can be mounted separately according to requirements resulting from critical environmental conditions • Further improved measurement capability in demanding situations causing poor visibility (rain, dust, fog). • Short infrared laser pulses providing excellent interference immunity • Narrow measurement beam with low divergence for excellent spatial resolution • Measurement to almost any surface regardless of the angle of incidence of the beam and the surface characteristics • Significant enhancement of the maximum range based on predetection-averaging visit our webpage www.riegl.com

 Open the catalog to page 1
RIEGL LD05-HTGF-2

General Description LD05-HTGF Principle of Operation data i/o control / communication processor transmitter online full waveform analysis analog digital electronics unit Transmitter lens optical head Receiver lens An electrical pulse generator periodically drives a semiconductor laser transmitter, emitting infrared light pulses, which are fed into a glass fiber cable. The pulses are guided to the optical head and collimated by the transmitter lens. Part of the echo signal reflected by the target is coupled into the glass fiber cable via the receiver lens and guided back to the electronics unit....

 Open the catalog to page 2
RIEGL LD05-HTGF-3

General Description LD05-HTGF Main Applications • • • Distance and level measurements in high-temperature areas Level measurement of liquid steel in melting pots or in transfer ladles Robotic applications in nuclear power plants Measurement of the position, width, and thickness of glowing slabs in rolling mills The LD05-HTGF is optimized for measuring very hot and glowing targets in steel plants, rolling mills, foundries etc.: Transmitter and receiver optics are equipped with narrow-band optical filters to avoid disturbances of the measurement caused by the radiation of light and heat from the...

 Open the catalog to page 3
RIEGL LD05-HTGF-4

General Description LD05-HTGF Digitizing the echo signal and analyzing it allows excellent clutter suppression under demanding environmental conditions, i.e., in the presence of dust, smoke or fumes. To meet different application challenges, user parameters as measurement rate, maximum target count (first target only, last target only, all targets) or sensitivity are adjustable. Standard Interfaces: • WEB Interface for configuration via WEB browser Industrial Interfaces: • • Analog output 4 – 20 mA Digital switching output (2x) Optional Infrared Radiation Channel: With this option the LD05-HTGF...

 Open the catalog to page 4
RIEGL LD05-HTGF-5

The technical data can be influenced by the environmental conditions to a considerable extent, especially by the following parameters and conditions: • Surface temperature and reflection characteristics of the target • Distance to the target • Angle of incidence of the measurement beam • Optical attenuation of the gases between target and instrument 1) Depending on the surface temperature and the reflection coefficient of the target 2) One sigma @ 5 m range under RIEGL test conditions (except measurements at reflective foil / retro-reflective targets). 3) Note, that fiber lengths in excess of...

 Open the catalog to page 5
RIEGL LD05-HTGF-6

Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 6 of 13

 Open the catalog to page 6
RIEGL LD05-HTGF-7

1) Operating range selectable via TCP/IP port or serial interface. 2) Switching points adjustable via TCP/IP port or serial interface Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 7 of 13

 Open the catalog to page 7
RIEGL LD05-HTGF-8

1) With the optional telescope, the temperature range is only between -10° C and +60° C. Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 8 of 13

 Open the catalog to page 8
RIEGL LD05-HTGF-9

Technical Data LD05-HTGF Dimensional Drawings Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 9 of 13

 Open the catalog to page 9
RIEGL LD05-HTGF-10

case: main dimensions: weight: protection class: temperature range: aluminium, black anodized 120 x 80 x 50 mm 0.67 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) front view side view All dimensions in mm. Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 10 of 13

 Open the catalog to page 10
RIEGL LD05-HTGF-11

case: main dimensions: weight: protection class: temperature range: aluminium, black anodized (stainless steel version on request) 133 x 0 65 mm 0.4 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) SIDE VIEW FRONT VIEW Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 11 of 13

 Open the catalog to page 11
RIEGL LD05-HTGF-12

case: main dimensions: weight: protection class: temperature range: recommended air pressure: aluminium, black anodized 500 x 120 x 70 mm approx. 4.4 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) 2 - 4 bar Data sheet, RIEGL LD05-HTGF, 2019-09-16 page 12 of 13

 Open the catalog to page 12
RIEGL LD05-HTGF-13

Technical Data LD05-HTGF Remote Optical Head MK36-HT: case: main dimensions: weight: protection class: temperature range: recommended air pressure: aluminium, colorless anodized 655 x ∅ 285 mm 10 kg IP64 (glass fiber cables attached) -20° to +80° C (operation and storage) 2 – 4 bar Side view Copyright RIEGL Laser Measurement Systems GmbH © 2019 – All rights reserved. Use of this data sheet other than for personal purposes requires RIEGL’s written consent. This data sheet is compiled with care. However, errors cannot be fully excluded and alternations might be necessary. Datasheet RIEGL LD05-HTGF...

 Open the catalog to page 13

All RIEGL LMS catalogs and technical brochures

  1. RiACQUIRE

    4  Pages

  2. RIEGL VMX-2HA

    8  Pages

  3. RIEGL VZ-2000i

    10  Pages

  4. RIEGL VQ-1260

    10  Pages

  5. RIEGL VQ-1460

    10  Pages

  6. RIEGL VPX-1

    2  Pages

  7. RIEGL VMY-1

    4  Pages

  8. RIEGL VQ-680

    8  Pages

  9. RIEGL VMY-2

    8  Pages

  10. RIEGL VZ-600i

    8  Pages

  11. RIEGL VZ-200

    6  Pages

  12. RiMINING

    4  Pages

  13. VUX-160²³

    6  Pages

  14. RIEGL VZ-400i

    10  Pages

  15. RIEGL VMR

    4  Pages

  16. RDBLib

    2  Pages

  17. RiSOLVE

    4  Pages

  18. RIEGL VUX-240

    6  Pages

  19. RiPROCESS

    4  Pages

  20. RIEGL PH-VUX

    2  Pages

  21. RiSCAN PRO

    4  Pages

  22. RIEGL VUX-SYS

    4  Pages

  23. RIEGL VZ-400i

    2  Pages

  24. RiVLib

    4  Pages

  25. RiUNITE

    4  Pages

  26. RIEGL VMZ

    4  Pages

  27. RIEGL VZ-6000

    6  Pages

  28. RiPANO

    4  Pages

  29. RIEGL DR1560i

    2  Pages

  30. RiHYDRO

    2  Pages

Archived catalogs

  1. RIEGL VZ-4000

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.