197 ENP VENT VALVE WITH FLAME ARRESTER
2Pages

{{requestButtons}}

Catalog excerpts

197 ENP VENT VALVE WITH FLAME ARRESTER - 1

VENT VALVE WITH END OF LINE FLAME ARRESTER Mod. 197 EN P VENT APPLICATION Vent Valve with ribbon coil is a Protection System: deflagration end of line flame arrester in according with Directive 2014/34/EU and harmonized standard EN ISO 1 6852:201 6. - Stage I vapor recovery compliant. - The Flame Arrester protects tank from outside fire. - Surface Protection System is for all ATEX zone (0,1 and 2). - Vapor recovery of Truck system shall be connected for fill storage tank. GAS & VAPOR COMPATIBILITY Inflammable gases and vapors classification is necessary to correct use of flame arrester. UE-Type Examination Certificate EPT 19 ATEX 3333 X is for Explosion Group “IIB3” tested with Ethylene and compatible for all gas with MESG 0.65 mm for example: Ammonia, Industrial methane, Blas-furnace gas, Carbon monoxide, Propane, Butane, Pentane, Esane, Eptane, Iso-octane, Decane, Benzene, Xilene, Cyclohexane, Acetone, Ethyl-methyl-ketone, Methyl acetate, Ethyl acetate, Normal propyl acetate, Normal butyl acetate, Amyl acetate, Cloroethylene, Methanol, Ethanol, Iso Butanol, Normal Butanol, Amyl alcohol and Ethyl nitrite. Use only for gas or vapor with MESG 0.65 mm. Marked “IIC” for Hydrogen and gas/vapor with MESG < 0.5 mm 197 EN-P H2. Burning rating BC=b and tBT=1 min and for “H2” model BC=c and tBT=0 min. Max operational temperature 60°C. - Standard model is for traditional fuel without additives. ON REQUEST: - “PTFE” coated model is for special fuel, non-aggresive solvents or chemical products. - “SS” model is for aggressive solvents, acids or bases. RIDART s.r.l. via Adua. 17 - 21045 Gazzada Schianno (VA) ITALY P.IVA/C.F. IT 01454770122 www.ridart.it info@ridart.it +39 0332 463301 Product Certification, Declaration of Conformity, User Manual and Testing on: www.ridart.it/support The Data and Images are not binding. We reserve the right to make changes without notice. Pressure & Flow Tolerances ±20%.

Open the catalog to page 1
197 ENP VENT VALVE WITH FLAME ARRESTER - 2

- Vent valve is only for vertical installation at the end of vapor pipeline. - For 1 ”1 /2 pipeline 197 -50 + adaptor 2”x1 ”1 / 2 - For 3” pipeline use 197-100 + adaptor 4”x3” - For 5” pipeline 197-150 + adaptor 6”x5” - For correct installation follow the Directives and product User Manual. - Explosion Group is “IIB3” in according with EN ISO 1 6852 (MESG 0.65 mm). - Explosion Group is “IIC” in according with EN ISO 1 6852 (MESG < 0.5 mm). - Contact our technical department for custom application or maintenance by email to: qualitv@ridart.it - Product Certification, Declaration of...

Open the catalog to page 2

All Ridart srl catalogs and technical brochures

  1. 190 VENT CAP

    1 Pages

  2. 197 ENP

    2 Pages

  3. RIDART CATALOG

    39 Pages