1. Catalogs
  2. Ridart srl
  3. 1534/1524 EN P VAPOR RECOVERY CAMLOCK

1534/1524 EN P VAPOR RECOVERY CAMLOCK

1534/1524 EN P VAPOR RECOVERY CAMLOCK

1534/1524 EN P VAPOR RECOVERY CAMLOCK

Product catalog summary
Overview
This document outlines the specifications and usage guidelines for a protection system featuring a ribbon coil deflagration in-line flame arrester, compliant with Directive 2014/34/EU and harmonized standard EN ISO 16852:2016. It is designed for use in hydrocarbon or chemical pipelines and is compliant with Stage I vapor recovery.

Specifications
  • The flame arrester prevents fire propagation into piping and is suitable for all ATEX zones (0, 1, and 2).
  • Maximum distance from potential ignition is 50 pipe diameters.
  • Maximum operational pressure is 0.1 bar.
  • Maximum operational temperature is 60°C.
  • Material specifications include aluminum for the male and female body, stainless steel for ribbon coil, support, screws, springs, and bolts, and Viton® for seals.

Compatibility
  • Suitable for inflammable gases and vapors with MESG > 0.65 mm, including a wide range of chemicals such as ammonia, industrial methane, propane, and more.
  • Explosion Group “IIB3” tested with Ethylene.

Installation and Maintenance
  • The flame arrester can be installed vertically or horizontally and is unidirectional, with the safety side being the female thread.
  • Follow directives and the product user manual for correct installation.
  • Always replace the product after fire or deflagration.
  • Warranty expires if tampered with, compromising safety protection.

Additional Information
  • Contact the technical department for custom applications or maintenance at [email protected].
  • Product certification, declaration of conformity, and user manuals are available at www.ridart.it/support.
  • Pressure and flow tolerances are ±20%.
See more

Catalog excerpts

1534/1524 EN P VAPOR RECOVERY CAMLOCK-1

1534 EN P - 1524 EN P VAPOR RECOVERY ADAPTER In-Line Deflagra on Flame Arrester It’s a Protec on System with ribbon coil deflagra on in-line flame arrester according with Direc ve 2014/34/EU and harmonized standard EN ISO 16852:2016. - Used for hydrocarbons or chemical pipeline. - Stage I vapor recovery compliant. - The Flame Arrester avoids propaga on of fire into the piping. - Surface Protec on System is for all ATEX zone (0, 1 and 2). The best performances allowed by the new regula on - Max distance from the poten al ignic on is 50 pipe’s diameter. - Max opera onal pressure (rela ve) is 0,1 bar. Gas & Vapor compa bility Inflammable gases and vapours classifica on is necessary to correct use of flame arrester. UE-Type Examina on Cer ficate EPT 18 ATEX 3053 X is for Explosion Group “IIB3” tested with Ethylene and compa ble for all gas with MESG > 0.65 mm for example: Ammonia, Industrial methane, Blas-furnace gas, Carbon monoxide, Propane, Butane, Pentane, Esane, Eptane, Iso-octane, Decane, Benzene, Xilene, Cyclohexane, Acetone, Ethyl-methyl-ketone, Methyl acetate, Ethyl acetate, Normal propyl acetate, Normal butyl acetate, Amyl acetate, Cloroethylene, Methanol, Ethanol, Iso Butanol, Normal Butanol, Amyl alcohol and Ethyl nitrite. Use only for gas or vapor with MESG > 0.65 mm. Burning ra ng BC=b, tBT=1 min. Max opera onal temperature 60°C. MALE BODY RIBBON COIL & SUPPORT STAINLESS STEEL SCREWS, SPRING & BOLTS STAINLESS STEEL FEMALE BODY

 Open the catalog to page 1
1534/1524 EN P VAPOR RECOVERY CAMLOCK-2

PROTECTED SIDE FLOW l/min (230 mbar) Chemical Suitability - Standard model is for tradi onal fuel without addi ves. 1524 EN P Installa on - In-line flame arrester is for ver cal or horizontal installa on. - Protec on System is unidirec onal, the safety side is the FEMALE thread. - For correct installa on follow the Direc ves and product User Manual. - Explosion Group is “IIB3” in according with EN ISO 16852 (MESG > 0.65 mm). - Contact our technical department for custom applica on or maintenance by email to: [email protected]. - Product Cer fica on, Declara on of Conformity and User Manuals are...

 Open the catalog to page 2

All Ridart srl catalogs and technical brochures

  1. Ridart 6000

    3  Pages

  2. 190 VENT CAP

    2  Pages

  3. RIDART CATALOG

    39  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry