Overview: The document provides technical specifications and details for Richter Pipeline Strainers, designed for use in corrosive environments. These strainers are lined with PFA, with an optional antistatic PFA-L lining, and are suitable for filtering particles ranging from 85 to 2000 µm. They operate effectively within a temperature range of -60 °C to +150 °C (-76 °F to +300 °F).
Specifications:
  • The strainers are constructed from ductile cast iron EN-JS 1049 (ASTM A395), ensuring durability and compliance with chemical industry standards.
  • The PFA lining offers robust protection against corrosive chemicals, with a thick-walled design to prevent damage from permeating substances.
  • Filter cross-cut surface is ≥ 130% of DN with a standard mesh of 250 µm, except for DN 65.
  • Pressure range is up to 16 bar, with temperature capabilities up to 150 °C (300 °F) and low temperatures down to -60 °C (PS 12 bar).
  • High vacuum stability is achieved through interlocked lining.
Installation and Dimensions:
  • Face-to-face dimensions conform to ISO 5752 - R.1 (DIN EN 558-1 R.1), with flanges according to ISO 7005-2 PN 16 DIN 2532/33, and can be drilled to ASME standards upon request.
  • ANSI/ISA 75-08.01 Cl.150 and Cl.300 standards are applicable for certain sizes, with flanges to ASME B16.5 150 lbs and Cl.300, respectively.
  • Flange with groove according to DIN 2512 is available on request.
Materials and Components:
  • Shell and cover are made from ductile cast iron EN-JS 1049 (ASTM A395).
  • Seat ring and strainer basket components are made from modified PTFE.
  • Filterweb options include 85, 250, 500, 1000 ETFE, and 2000 µm.
  • Strainer basket support and locking rope are also made from PTFE.
  • Cover bolting is constructed from stainless steel.
Dimensions: The document provides detailed dimensions for various DN sizes, including face-to-face flange dimensions according to ISO 5752 series 1/ISO 7005-2 PN 16, with ANSI/ISA dimensions available on request.
See more

Catalog excerpts

Pipeline Strainers-1

Richter Pipeline Strainers Lining PFA, optional PFA-L antistatic

 Open the catalog to page 1
Pipeline Strainers-2

Face-to-face flange dimensions to ISO 5752 series 1/ISO 7005-2 PN 16 Dimensions for ANSI/ISA-on request *reduced passage all dimensions in mm • The ductile cast iron EN-JS 1049 (ASTM A395) used for the shell, meets the requirements of the chemical industry • The fluoroplastic lining PFA provides a reliable protection against corrosive chemicals • The especially thick-walled lining prevents damage even with permeating chemicals • Filter cross-cut surface > 130% of DN with standard mesh 250 pm (except of DN 65) • Further technical data: Pressure range to 16 bar* Temperature to 150 °C (300°F) Low...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.