Catalog excerpts
Operating range, hydraulic coverage Operating pressure: Up to 275 psi (19 bar), depending on temperature. Pump standstill vacuum permissible depending on temperature and pump specification. Operating temperature: From -20 to 360 °F (-30 °C to 180 °C), depending on configuration and pressure. Solids containing liquids: When solids containing media are pumped, flushing of bearings can be carried out using an external sealing liquid. This also refers to fluids which Presented by: Richter Inc. A Unit of IDEX Corporation 406 State Street, Cedar Falls, 50613 IA, USA Tel. +1(319) 266-1741, Fax +1(319) 273-8157 Headquarter: Richter Chemie-Technik GmbH Otto-Schott-Str. 2, D-47906 Kempen, Germany Tel. +49 (0) 21 52/146-0, Fax +49 (0) 21 52/146-190 www.richter-ct.com, richter-info@idexcorp.com 8 Publication No. 615us 05.09 © Richter Chemie-Technik GmbH. Subject to change without notice. Printed in Germany. Richter Heavy Duty Lined Mag-Drive ASME/ANSI Pumps tend to crystallize. Low solids content of small particle size can often be handled even without such ancillary equipment. Please ask for details on a case to case basis. Dry-run optimized SAFEGLIDE® PLUS sleeve bearings Corrosion-re
Open the catalog to page 1• Dichloroethylene • Chlorine dioxide • Sodium hypochlorite • Freon 113 • Ethers • Acetone • Bromine • CIP solutions MNKA Richter heavy duty lined mag-drive ASME/ANSI chemical pump MNKA Applications Demanding applications with corrosive, hazardous, polluted and pure media in chemical, pharmaceutical, petrochemical, water treatment, pulp and metal processing, and waste disposal/recycling industries. Economical alternative to pumps made of special metals like Alloy C, titanium, nickel etc. Operating range • Rows to 400 US gpm (95 m!/h) • Heads to 480 feet (146 m) • Temperatures to 360 °F...
Open the catalog to page 2MNKA Richter heavy duty lined mag-drive ASME/ANSI chemical pump MNKA Applications Demanding applications with corrosive, hazardous, polluted and pure media in chemical, pharmaceutical, petrochemical, water treatment, pulp and metal processing, and waste disposal/recycling industries. Economical alternative to pumps made of special metals like Alloy C, titanium, nickel etc. Flows to 400 US gpm (95 m3/h) Heads to 480 feet (146 m) Temperatures to 360 °F (180 °C) Pressures to 275 psig (19 bar) For higher flows to 2650 US gpm (600 m3/h) and temperatures to 400 °F (200 °C) see Richter´s mag-drive...
Open the catalog to page 3Parts and Additional features and options Casing drain available as an option: • allows for safe and easy pump drainage • for standstill conditions especially with crystallizing media Casing drain provides a flushing circuit via the lowest point of the pump. External corrosion • casing fasteners of stainless steel Quality Quality system to ISO 9001. Temperature monitoring Available as an option, measuring the liquid's temperature. Type code: magnetic MNKA/.., highly permeation resistant PFA-P .../F-P 'PP/PE-UHMW, antistatic and highly permeation resistant linings on request 21 Housing...
Open the catalog to page 4MNKA Parts and material list Modular interchangeability Size Bearing pedestal Additional features and options Plain Inner bearing magnet set assembly* External corrosion protection • epoxy coating • casing fasteners of stainless steel Hollow drive shaft Casing drain available as an option: • allows for safe and easy pump drainage • for standstill conditions especially with crystallizing media Casing drain provides a flushing circuit via the lowest point of the pump. Drive Adapter magnet assembly* Illustration: Frame-mounted pump with oil bath lubrication. Not shown: grease lubrication and...
Open the catalog to page 5The MNKA in detail: built for outstanding service life Optional SAFEGLIDE^ PLUS silicon carbide (SSiC) sleeve bearings provide dry-run capability. That helps to overcome short-term upsets and gives valuable time to make corrections before pump damage occurs (see separate brochure). Radial rubbing safety ring ("bump ring”): no danger for the containment shell even in the unlikely event of a failure of the ball bearings. Shown: optionr'-------— Tough all-metal external pump casing absorbs hydraulic loads and those from suction and discharge piping. Unlike non-armoured plastic pumps, no...
Open the catalog to page 6Pump dimensions for frame-mounted and close-coupled designs Dimensions inch (mm)/Weight appr. lbs (kg) * e.g. 3x2x6” = Suction x Discharge x Impeller (in inches). Flanges ANSI B 16.5/CI.150 ** Frame foot has only one mounting hole to ground on pump center line *** Weights are for bare-shaft pump MNKA Dimensions vary depending on motor manufacturer.
Open the catalog to page 7Operating pressure: Solids containing liquids: tend to crystallize. Low solids When solids containing media content of small particle size to 18CrC), depending on con-ding on temperature. Pump are pumped, flushing of bear-can often be handled even standstill vacuum permissible ings can be carried out using without such ancillary equip- depending on temperature an external sealing liquid. This ment. Please ask for details also refers to fluids which on a case to case basis. RICHTER Publication No. 615en 05.09 © Richter Chemie-Technik GmbH. Subject to change without notice. Printed in...
Open the catalog to page 8All Richter Chemie Technik catalogs and technical brochures
-
Sight glasses
6 Pages
-
Low-pressure safety valves
4 Pages
-
Lined safety relief valves
4 Pages
-
Safety valves
6 Pages
-
Control ball valves
6 Pages
-
Pipeline Strainers
2 Pages
-
Dangerous Goods
4 Pages
-
Lined check valves
6 Pages
-
Sampling valves PA/F, PA/S
6 Pages
-
Tank Bottom Valve System
8 Pages
-
Chlor-alkali Electrolysis
6 Pages
-
Mechanical Seal Pump SCK
10 Pages