Magnetic Drive Pump  MNKA, MNKA-B - 1

Operating range, hydraulic coverage Operating pressure: Up to 275 psi (19 bar), depending on temperature. Pump standstill vacuum permissible depending on temperature and pump specification. Operating temperature: From -20 to 360 °F (-30 °C to 180 °C), depending on configuration and pressure. Solids containing liquids: When solids containing media are pumped, flushing of bearings can be carried out using an external sealing liquid. This also refers to fluids which Presented by: Richter Inc. A Unit of IDEX Corporation 406 State Street, Cedar Falls, 50613 IA, USA Tel. +1(319) 266-1741, Fax +1(319) 273-8157 Headquarter: Richter Chemie-Technik GmbH Otto-Schott-Str. 2, D-47906 Kempen, Germany Tel. +49 (0) 21 52/146-0, Fax +49 (0) 21 52/146-190 www.richter-ct.com, richter-info@idexcorp.com 8 Publication No. 615us 05.09 © Richter Chemie-Technik GmbH. Subject to change without notice. Printed in Germany. Richter Heavy Duty Lined Mag-Drive ASME/ANSI Pumps tend to crystallize. Low solids content of small particle size can often be handled even without such ancillary equipment. Please ask for details on a case to case basis. Dry-run optimized SAFEGLIDE® PLUS sleeve bearings Corrosion-re

Open the catalog to page 1
Magnetic Drive Pump  MNKA, MNKA-B - 2

• Dichloroethylene • Chlorine dioxide • Sodium hypochlorite • Freon 113 • Ethers • Acetone • Bromine • CIP solutions MNKA Richter heavy duty lined mag-drive ASME/ANSI chemical pump MNKA Applications Demanding applications with corrosive, hazardous, polluted and pure media in chemical, pharmaceutical, petrochemical, water treatment, pulp and metal processing, and waste disposal/recycling industries. Economical alternative to pumps made of special metals like Alloy C, titanium, nickel etc. Operating range • Rows to 400 US gpm (95 m!/h) • Heads to 480 feet (146 m) • Temperatures to 360 °F...

Open the catalog to page 2
Magnetic Drive Pump  MNKA, MNKA-B - 3

MNKA Richter heavy duty lined mag-drive ASME/ANSI chemical pump MNKA Applications Demanding applications with corrosive, hazardous, polluted and pure media in chemical, pharmaceutical, petrochemical, water treatment, pulp and metal processing, and waste disposal/recycling industries. Economical alternative to pumps made of special metals like Alloy C, titanium, nickel etc. Flows to 400 US gpm (95 m3/h) Heads to 480 feet (146 m) Temperatures to 360 °F (180 °C) Pressures to 275 psig (19 bar) For higher flows to 2650 US gpm (600 m3/h) and temperatures to 400 °F (200 °C) see Richter´s mag-drive...

Open the catalog to page 3
Magnetic Drive Pump  MNKA, MNKA-B - 4

Parts and Additional features and options Casing drain available as an option: • allows for safe and easy pump drainage • for standstill conditions especially with crystallizing media Casing drain provides a flushing circuit via the lowest point of the pump. External corrosion • casing fasteners of stainless steel Quality Quality system to ISO 9001. Temperature monitoring Available as an option, measuring the liquid's temperature. Type code: magnetic MNKA/.., highly permeation resistant PFA-P .../F-P 'PP/PE-UHMW, antistatic and highly permeation resistant linings on request 21 Housing...

Open the catalog to page 4
Magnetic Drive Pump  MNKA, MNKA-B - 5

MNKA Parts and material list Modular interchangeability Size Bearing pedestal Additional features and options Plain Inner bearing magnet set assembly* External corrosion protection • epoxy coating • casing fasteners of stainless steel Hollow drive shaft Casing drain available as an option: • allows for safe and easy pump drainage • for standstill conditions especially with crystallizing media Casing drain provides a flushing circuit via the lowest point of the pump. Drive Adapter magnet assembly* Illustration: Frame-mounted pump with oil bath lubrication. Not shown: grease lubrication and...

Open the catalog to page 5
Magnetic Drive Pump  MNKA, MNKA-B - 6

The MNKA in detail: built for outstanding service life Optional SAFEGLIDE^ PLUS silicon carbide (SSiC) sleeve bearings provide dry-run capability. That helps to overcome short-term upsets and gives valuable time to make corrections before pump damage occurs (see separate brochure). Radial rubbing safety ring ("bump ring”): no danger for the containment shell even in the unlikely event of a failure of the ball bearings. Shown: optionr'-------— Tough all-metal external pump casing absorbs hydraulic loads and those from suction and discharge piping. Unlike non-armoured plastic pumps, no...

Open the catalog to page 6
Magnetic Drive Pump  MNKA, MNKA-B - 7

Pump dimensions for frame-mounted and close-coupled designs Dimensions inch (mm)/Weight appr. lbs (kg) * e.g. 3x2x6” = Suction x Discharge x Impeller (in inches). Flanges ANSI B 16.5/CI.150 ** Frame foot has only one mounting hole to ground on pump center line *** Weights are for bare-shaft pump MNKA Dimensions vary depending on motor manufacturer.

Open the catalog to page 7
Magnetic Drive Pump  MNKA, MNKA-B - 8

Operating pressure: Solids containing liquids: tend to crystallize. Low solids When solids containing media content of small particle size to 18CrC), depending on con-ding on temperature. Pump are pumped, flushing of bear-can often be handled even standstill vacuum permissible ings can be carried out using without such ancillary equip- depending on temperature an external sealing liquid. This ment. Please ask for details also refers to fluids which on a case to case basis. RICHTER Publication No. 615en 05.09 © Richter Chemie-Technik GmbH. Subject to change without notice. Printed in...