CU4 Rectangular fire damper
6Pages

{{requestButtons}}

Catalog excerpts

CU4 Rectangular fire damper - 1

NF-Clapets coupe-feu et V Volets de désenfumage D.A.S. NF 26 64 CU4 Rectangular fire damper www.marque e-nf.com

Open the catalog to page 1
CU4 Rectangular fire damper - 2

Rectangular fire damper Rectangular re dampers CU4 are installed in ventilation ducts passing through a construction element in order to stop the propagation of re. They dispose of a modular operating mechanism positionned completely outside the wall. The rectangular re damper CU4 has a re resistance up to 240' and was tested at 500Pa. The refractory casing is asbestos free and resistant to humidity. The re damper can be equipped with a common fusible link mechanism up to a motorized mechanism. 9 • Tested according to the European standard EN 1366-2 at 500Pa • Suitable for mounting in rigid...

Open the catalog to page 2
CU4 Rectangular fire damper - 3

Rectangular fire damper CU4L Elongated tunnel The CU4L damper is a CU4 damper of which the tunnel is extended to one or both sides Applications: - The damper can not exceed one or both sides of the tunnel - To allow an easy connection in case of a thick wall - To allow the installation of a grill directly on the tunnel of the damper x = elongation on the side of the mechanism y = elongation on the other side of the mechanism x of y>0 Rigid wall ve = damper mounted directly in the wall ho = damper mounted directly in a floor/ceiling i o = fire can come from either direction Pa = Pascal E =...

Open the catalog to page 3
CU4 Rectangular fire damper - 4

Rectangular fire damper CFTH: Operating mechanism with fusible link The operating mechanism CFTH automatically unlocks the blade when the temperature in the duct exceeds 72°C. The damper needs to be rearmed manually Standard: Fusible link 72° C Manual unlocking possible Manual rearmation, use the enclosed key (turn clockwise) IP42 FCU: Unipolar end of range switch FCU/DCU : Unipolar end and beginning of range switches FCB/DCB : Bipolar end and beginning of range switches fig. CU4 + CFTH MANO: Upgradable automatic / remote controlled operating mechanism with fusible link The operating...

Open the catalog to page 4
CU4 Rectangular fire damper - 5

Rectangular fire damper The damper blade exceeds the tunnel as from Hn ≥ 300mm The damper exceeds the tunnel as from Hn ≥ 550mm • Connection to ducts with 30 mm anges • The connection of damper/duct: - with either sliding prole - or with bolts - or with clamps • The four corners of the frame are provided with elliptical holes Ø 8,5 x 16mm. - Connection to ducts with 20mm anges - Elliptical holes Ø 6,5 x 16mm CFTH MANO(+ME) - Connection to ducts with 40mm anges - Elliptical holes Ø 8,5 x 16mm

Open the catalog to page 5
CU4 Rectangular fire damper - 6

Rectangular fire damper Connection to a duct by insertion Ø 8,5 x 16mm No connection. Used on transfer dampers • Elongated frame to avoid the damper blade from exceeding the tunnel • Connection to ducts with 30mm anges. • The four corners of the frame are provided with elliptical holes Ø 8,5 x 16mm. • Maximum extension on 1 side = 500mm. • Maximum extension on both sides together = 600mm. • Extensions in steps of 50mm. Round connection on a rectangular damper Round connection with rubber sealing ring Grill, very well suited as protection grill for an end piece of a ductsystem or for a...

Open the catalog to page 6