1. Catalogs
  2. Rf-t
  3. AVANTAGE

AVANTAGE

AVANTAGE
1 / 34 PagesView full catalog

AVANTAGE

Product catalog summary
Declaration of Performance
The AVANTAGE smoke evacuation shutter is designed for smoke control systems, suitable for both multi-compartment and single-compartment applications at fire temperatures. It complies with the European standard EN 12101-8:2011 and has been tested for fire resistance according to EN 1366-10.

Product Presentation
The AVANTAGE shutter is known for its superior airtightness and is available in single (1V) and double (2V) units, as well as a motorized version (1V ME) for remote resetting. It offers fire resistance of 60 or 120 minutes and ensures minimal pressure loss. The shutters are suitable for installation in various shaft types, including calcium-silicate and concrete, and are maintenance-free.

Variants and Dimensions
- AVANTAGE 1V: Single shutter with fire resistance up to 120 minutes.
- AVANTAGE 2V: Double shutter with similar fire resistance.
- AVANTAGE 1V ME: Motorized version allowing remote resetting.
Dimensions vary, with nominal dimensions ranging from 300x385 mm to 1100x1105 mm depending on the variant.

Installation and Operation
Installation must adhere to the provided manual and classification report. The shutters can be installed in various shaft types, ensuring the blade moves freely. Operation involves manual or remote unlocking and resetting, with specific instructions for each variant.

Electrical Connection
Electrical supply can be connected at any corner of the shutter. Proper sealing with fire-resistant adhesive is required after cable installation.

Storage and Handling
The product should be stored in a dry area, avoiding impacts, water contact, and deformation. It should not be used as a scaffold or table.

Approvals and Certificates
The product is certified under EN 12101-8:2011 and has been tested for compliance with relevant fire resistance standards.

Specifications
The document provides detailed specifications for various models of air passage systems, including AVANTAGE 1V60, 1V120, 2V60, and 2V120. It includes tables with measurements of free air passage in square meters (m²) for different height and width configurations.

Procedures
The document outlines the sample order process for AVANTAGE products, specifying options such as the number of shutters, fire resistance duration, dimensions, and additional features like resetting motors and type magnets.

Standards and Certifications
The products are tested by official institutes, and the NF-label guarantees conformity with NF S 61-937 Parts 1 and 10 standards, as well as compliance with national fire resistance classification decrees. Certification is provided by AFNOR Certification.

Recommendations
It is advised that the products should not be manipulated in any way other than described in the manual, as this would void the guarantee and Rf-Technologies would decline any responsibility.
See more

Catalog excerpts

AVANTAGE-1

Smoke evacuation shutter. Rf-Technologies nv  Lange Ambachtstraat 40  9860 Oosterzele  Belgium  Tel +32 9 362 31 71  Fax +32 9 362 33 07  [email protected]

 Open the catalog to page 1
AVANTAGE-2

Product presentation AVANTAGE 5 Range and dimensions AVANTAGE 1V 6 Range and dimensions AVANTAGE 2V 7 Range and dimensions AVANTAGE 1V ME 8 Options - at the time of order 9 Shock absorbers for the doors 14 Installation into vertical concrete shaft with mounting frame 15 Installation into vertical concrete shaft without mounting frame 17 Installation into vertical shaft with built-in mounting frame: general instructions for all types of shafts (other than concrete) 18 Installation into vertical shaft (without a mounting frame): general instructions for all types of shafts (other than concrete)...

 Open the catalog to page 2
AVANTAGE-3

Wn = nominal width Hn = nominal height Sn = free air passage E = integrity I = thermal insulation S = smoke leakage 60/120 = fire resistance time Pa = pascal o -> i = meets the criteria from the outside (o) to the inside (i) i <-> o = fire side not important AA = automatic activation multi = multi compartment 1500 = pressure level 3 (1500Pa) ved = vertical duct hod = horizontal duct vew = vertical wall penetration V = volt W = watt V AC = Volt alternating current V DC = Volt direct current E.TELE = power supply magnet E.ALIM = power supply motor Auto = automatic Tele = remote controlled Pnom...

 Open the catalog to page 3
AVANTAGE-4

6. Declared performance according to EN 12101-8:2011 Type of installation: shaft-mounted 0/180°. Minimal in-between distances authorised. Range 300x385 mm ≤ Avantage 1V ≤ 700x1075 mm; 350x385 mm ≤ Avantage 2V ≤ 1100x1105 mm; 350x385 mm ≤ Avantage 1V ME ≤ 700x1075 mm Installation Classification 1 EI 60 (ved i n o) S 1500 AA multi (fire resistance according to EN 1366-10, classification according to EN 13501-4) 5. Harmonised standard / European Assessment Document; notified body / European Technical Assessment, Technical Assessment Body, notified body; certificate of constancy of performance: Shaft...

 Open the catalog to page 4
AVANTAGE-5

Product presentation AVANTAGE Product presentation AVANTAGE The smoke evacuation shutter Avantage is noted for its superior airtight properties. The shutter is available as single (1V) and double (2V) shutter units; it is also available in a motorised version (Avantage ME) that allows the remote resetting of the blade. Developed in accordance with the European product standard EN 12101-8 and tested with front grill according to the EN 1366-10 standard, Avantage offers a fire-resistance of 60 or 120 minutes (see the classification overview), and ensures minimum pressure loss. Smoke evacuation...

 Open the catalog to page 5
AVANTAGE-6

Avantage smoke evacuation shutter, single (1V) shutter unit. ■ 1 shutter ■ fire resistance till 60 minutes / 120 minutes 5. blocking mechanism + automatic locking at 90° 7. front protection grill (compulsory) 2. Sealing if mounting frame 3. Mounting frame (optional) 4. Nominal dimensions shutter Wn x Hn 5. Built-in dimensions without mounting frame (Wn+10) x (Hn+10)mm 6. Built-in dimensions with mounting frame (Wn+20) x (Hn+20)mm 7. Overall (outside) dimensions of the shutter (Wn+54) x (Hn+54)mm

 Open the catalog to page 6
AVANTAGE-7

Variant AVANTAGE 2V60 - 2V120_ Avantage smoke evacuation shutter, double (2V) shutter unit. ■ 2 shutters ■ fire resistance till 60 minutes / 120 minutes 5. blocking mechanism + automatic locking at 90° 8. front protection grill (compulsory) 2. Sealing if mounting frame 3. Mounting frame (optional) 4. Nominal dimensions shutter Wn x Hn 5. Built-in dimensions without mounting frame (Wn+10) x (Hn+10)mm 6. Built-in dimensions with mounting frame (Wn+20) x (Hn+20)mm 7. Overall (outside) dimensions of the shutter (Wn+54) x (Hn+54)mm

 Open the catalog to page 7
AVANTAGE-8

Motorised (ME) Avantage 1V smoke evacuation shutter that allows the remote resetting of the blade. ■ with resetting motor ■ 1 shutter ■ fire resistance till 60 minutes / 120 minutes 5. blocking mechanism + automatic locking at 90° 8. front protection grill (compulsory) 2. Sealing if mounting frame 3. Mounting frame (optional) 4. Nominal dimensions shutter Wn x Hn 5. Built-in dimensions without mounting frame (Wn+10) x (Hn+10)mm 6. Built-in dimensions with mounting frame (Wn+20) x (Hn+20)mm 7. Overall (outside) dimensions of the shutter (Wn+54) x (Hn+54)mm

 Open the catalog to page 8
AVANTAGE-9

Evolution - kits Evolution - kits KITS VD24-VA Electromagnet 24 V DC (not applicable for ME model) Electromagnet 48 V DC (not applicable for ME model) KITS FDC-VA Limit switches 'open/closed' KITS ME-AVANM Mounting frame (delivered separately) Technical front protection grill (aluminium frame and perforated plate, fastened with screws 4.8x19mm), free air passage of 69,4% Options - at the time of order Technical front protection grill (aluminium frame and perforated plate, fastened with screws 4.8x19mm), free air passage of 69,4%

 Open the catalog to page 9
AVANTAGE-10

Storage and handling Storage and handling As this product is a safety element, it should be stored and handled with care. Avoid: • any kind of impact or damage • contact with water • deformation of the casing It is recommended: • to unload in a dry area • not to flip or roll the product to move it • not to use the damper as a scaffold, working table, etc. • not to store smaller dampers inside larger ones Installation General points ∎  ∎  ∎  ∎  ∎  ∎  The installation must comply with the installation manual and the classification report. The installation of the shaft must comply with the classification...

 Open the catalog to page 10
AVANTAGE-11

Installation Operation: closing 1 1. Resetting 1V Manual: Turn the key 20° clock wise and withdraw it. Push the blocking mechanism. Close the shutter by pulling the metal profile. 2. Resetting 2V Manual: Press on both blocking devices to deactivate them. 3. Turn the key 20° clock wise and withdraw it. Close both shutters together by pulling on the metal profiles. Make sure that the shutters hook in each other as illustrated. 4. Resetting ME Manual: Turn the key 20° clock wise and withdraw it. Push the blocking mechanism. Close the shutter by pulling the metal profile. Remote: Power the actuator...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.