Catalog excerpts
REZONTECH FLAME DETECTOR THE BEST SOLUTION FOR FIRE DETECTION SYSTEM Rezontech Building, 72-9 Beolmal-st, Donggan-gu, Anyang-si, Gyeonggi-do, South Korea Tel. + 82-31-348-4246~8 Fax. +82-31-348-3004 E. sales@rezontech.com Web. www.rezontech.com Design by DesignTiki 2018.04 I Copyright©2018.REZONE TECH Co., Ltd. All rights Reserved THE BEST SOLUTION FOR FIRE DETECTION SYSTEM
Open the catalog to page 1REZONTECH FLAME DETECTOR Designed and manufactured in South Korea, under Rezontech' s technology and the own strict quality control system with international laboratories such as FM, ATEX, CCCF, IECEX, KFI(Korea Fire Institute) and so on. This expertise and responsibility for quality will make Rezontech meet all your needs from the fire detection. PRINCIPLE The Rezontech flame detector can promptly analyze sensory inputs from the ultraviolet and infrared light sources emitted by a flame to alert against fires. IR3 flame detection sensing three specific wavelength bands within the Infrared...
Open the catalog to page 2/ UV/IR FLAME DETECTOR d IR3 & HYDROGEN FLAME DETECTOR normal: r^?9ALRAT|NG 'O 32VDC t 8W MAX Rating "OC. AA 125VAC. , 2A 250VAC / JJRE CODE T6 I Type | UV/ IR Enclosure Material | SUS 316 Detection Range | 98.5ft(30m) Weight | 3.2kg Field Of View | H90° V90° Response | Typically 5 seconds Operating Temperature Range | -40 °C to +75 C Humidity Range | Up to 95% relative humidity ELECTRICAL SPECIFICATION Operating Voltage | 24 VDC (17 VDC to 32 VDC) Power Consumption | 1.8W maximum at 32VDC Output | Relay Contacts (Fire, Fault, Warning Alarm) 4-20mA Current Output RS-485 Proprietary...
Open the catalog to page 3/ PRODUCT LINE-UP FLAME DETECTOR TESTER Rezontech test lamp produces a particular frequency of IR and UV radiation to exclusively test Rezontech flame detectors within 30 seconds. Rezontech test lamp is proper to use in hazardous areas because it can make the flame detector tested without the needs of an actual fire. PRODUCTS TL-3000 ■ Operation Distance | ■ Target Model | ■ Operation Time | ■ Dimension & Weight | ■ Enclosure | IECEX FM,ATEX NEPSI (CNEX) ATEX NEPSI EX-GOST ■ Operation Distance ■ Target Model ■ Operation Time ■ Dimension & Weight ■ Enclosure ■ Temperature Range 3m...
Open the catalog to page 4All REZONTECH catalogs and technical brochures
-
FIRE Detector RMD-5T
2 Pages
-
REZONTECH FLAME DETECTOR
8 Pages
-
PSU-20
5 Pages
-
Eagle Flame Detector Series
4 Pages
-
Condensed Fire Aerosol
7 Pages