This document provides guidelines for the installation of the FUKA dryer, an innovative device designed to enhance car wash operations. Proper site preparation is crucial for the device's long-term and trouble-free use.
Electrical Connection Preparation
The installation site must have a stable power supply with a minimum voltage of 230V (1 phase). The cable cross-section requirements are:
  • Up to 40 m: minimum 2.5 mm²
  • Over 40 m: minimum 4 mm²
The cable should protrude at least 2.5 m above the foundation level. A 20A fuse of class D, an FR switch-disconnector, and an RCD differential switch must protect the connection. The power cable should be encased in a corrugated plastic casing, extending 5 cm above the foundation.
Grounding Preparation
Proper grounding is essential for user safety, with a maximum resistance of 10 Ohms. Grounding must be performed and approved by an authorized person. The grounding connection should be close to the connecting cable and perpendicular to the base surface. Improper grounding may result in installation refusal and additional charges.
Steel Anchor and Concrete Foundation
A concrete foundation must be prepared at least 7 days before installation, using a steel anchor provided by the manufacturer. The trench should measure at least 70 cm x 50 cm and 120 cm deep. The power cable should be routed through the trench as specified. The steel anchor must be positioned horizontally, with the upper plate level with the ground. The structure should be stabilized and filled with at least B20 class concrete. Incorrect foundation construction may lead to installation refusal and additional charges.
Attaching the Machine to the Ground
For maximum stability, the foundation must be properly prepared. Key dimensions include a power cable cover height of 3.2 m, arm length of 2.9 m, and housing width of 0.5 m.
Contact Information
InnoSync s.r.o., Fuka – Mind Blowing Solutions, Rybna 716/24, 110 00 Prague, Czech Republic. Email: [email protected], Phone: +420 776 747 716, Website: www.airfuka.com
See more

Catalog excerpts

FUKA - PREPARATION FOR INSTALLATION CONCRETE FOUNDATION-2

Thank you for purchasing (or planning to purchase) our innovative device! We are convinced that with the help of our product - the FUKA dryer - you will take your car wash to the next level. To ensure long and trouble-free use of our product, the final installation site of the FUKA dryer must be properly prepared. Here are the basic requirements for preparing such a site: Preparing the electrical connection The place prepared for the installation of the device must be supplied with stable power supply with minimum voltage of 230V (1 phase) using a cable of the appropriate crosssection: • for cable...

 Open the catalog to page 2
FUKA - PREPARATION FOR INSTALLATION CONCRETE FOUNDATION-3

Attaching the machine to the ground In order to ensure maximum stability of the device during normal use, a proper foundation for the installation should be prepared in advance. Steel anchor + concrete foundation At least 7 days prior to the scheduled installation of the device, the concrete foundation must be constructed in accordance with the specifications below and with use a steel anchor previously supplied by the device manufacturer. To do this, you need to make a trench measuring minimum 70cm x 50cm and 120 cm deep. The power cable must be led into the trench in accordance with the specifications...

 Open the catalog to page 3
FUKA - PREPARATION FOR INSTALLATION CONCRETE FOUNDATION-5

height: 3,2 m arm lenght: 2,9 m housing width: 0,5 m InnoSync s.r.o. Fuka – Mind Blowing Solutions Rybna 716/24, 110 00 Prague, Czech Republic mail: [email protected] tel: +420 776 747 716 www.airfuka.com

 Open the catalog to page 5