1. Catalogs
  2. REXEL
  3. FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR

FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR

FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR

FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR

Product catalog summary
Introduction
This document provides guidelines for the installation of the FUKA dryer, emphasizing the importance of proper site preparation to ensure long-term, trouble-free operation.
Electrical Connection Preparation
The installation site must have a stable power supply with a minimum voltage of 230V (1 phase). The cable cross-section should be at least 2.5 mm2 for lengths up to 40 m, and 4 mm2 for longer cables. The cable should protrude at least 2.5 m above the foundation level. A 20A fuse of class D, an FR switch-disconnector, and an RCD differential switch are required. The power cable must be encased in corrugated plastic, extending 5 cm above the foundation.
Grounding Preparation
Proper grounding is crucial for user safety, with a maximum resistance of 10 Ohms. Grounding must be performed and approved by an authorized person, with the grounding connection close to the connecting cable.
Chemical Anchor on Existing Concrete Foundation
If excavation is not possible, the device can be installed on an existing concrete base using a steel plate and specialist glue. The concrete pedestal must be monolithic or prefabricated, with a minimum class of C25/30, and reinforced with anti-shrinkage mesh. Dimensions: width 6 m, depth 0.8 m, height 0.3 m. The foundation must be level, clean, stable, and undamaged.
Attaching the Machine to the Ground
A steel plate, supplied and mounted by the manufacturer, is used to secure the device. The plate dimensions are height: 3.2 m, arm length: 2.9 m, and housing width: 0.5 m.
Important Notes
Failure to meet the specified requirements for the foundation, electrical connection, or grounding may result in the installation team refusing to perform the installation and charging for travel and work costs.
See more

Catalog excerpts

FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR-1

Chemical anchor on existing concrete foundation

 Open the catalog to page 1
FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR-2

Thank you for purchasing (or planning to purchase) our innovative device! We are convinced that with the help of our product - the FUKA dryer - you will take your car wash to the next level. To ensure long and trouble-free use of our product, the final installation site of the FUKA dryer must be properly prepared. Here are the basic requirements for preparing such a site: Preparing the electrical connection The place prepared for the installation of the device must be supplied with stable power supply with minimum voltage of 230V (1 phase) using a cable of the appropriate crosssection: • for cable...

 Open the catalog to page 2
FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR-3

Attaching the machine to the ground In order to ensure maximum stability of the device during normal use, a proper foundation for the installation should be prepared in advance. Chemical anchor on existing concrete foundation If it is not possible to make an excavation and concrete the steel anchor, it is possible to install the device on an existing concrete base. The device is attached using a steel plate (delivered and assembled by the assembly team together with the device) screwed to the ground and additionally glued using specialist glue. To ensure the stability of the device, the concrete...

 Open the catalog to page 3
FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR-4

Steel plate Steel plate - supplied and mounted

 Open the catalog to page 4
FUKA - PREPARATION FOR INSTALLATION CHEMICAL ANCHOR-5

height: 3,2 m arm lenght: 2,9 m housing width: 0,5 m InnoSync s.r.o. Fuka – Mind Blowing Solutions Rybna 716/24, 110 00 Prague, Czech Republic mail: [email protected] tel: +420 776 747 716 www.airfuka.com

 Open the catalog to page 5

All REXEL catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.