1. Catalogs
  2. Resistencias Tope S.A.
  3. ATEX industrial fan heater
video corpo

ATEX industrial fan heater

ATEX industrial fan heater

ATEX industrial fan heater

Product catalog summary
ATEX Industrial Fan Heaters

Features:
  • Equipped with ATEX II 2GD cable glands for power and safety thermostat.
  • Motor fan series EVXP ATEX with three-phase voltage 230/400V 50Hz.
  • Includes a safety thermostat with manual reset and galvanized components.
  • ATEX certified electric heater battery.
Temperature Specifications:
  • Operational temperature range: -20°C to +40°C for both transported fluid and ambient conditions.
Options:
  • Power options up to 60 kW and various ATEX classifications for gas and dust versions.
  • Pre-wired ATEX control panels and construction options with centrifugal fans or stainless steel materials.
Remarks:
  • For GD versions, surface temperatures are reduced by 5°C for T4 and 10°C for T3 in dust areas.
Standards:
  • Tested for vibration control as per ISO 14964 and compliant with machine directive 2006/42/EC and Ecodesign Directive 2009/125/EC.
  • Mechanical protection standards according to EN ISO 12499 and turbine balancing as per ISO 1940.

ATEX Industrial Convectors

Features:
  • Certified under LCIE 03 ATEX 6386 X with ATEX II 2GD EExd IIC protection.
  • Available in single-phase 230V or three-phase 230/400V 50Hz configurations.
  • Constructed with painted support and perforated sheet casing.
Temperature Specifications:
  • Operational temperature range: -20°C to +60°C for both ambient and transport fluid.
Options:
  • Thermostat control with stainless steel thermowell and additional cable gland.
  • Special voltage and frequency options, and construction with stainless steel materials.
Remarks:
  • For GD versions, surface temperatures are reduced by 5°C for T4 and 10°C for T3 in dust areas.
Standards:
  • Tested for vibration control as per ISO 14964 and compliant with machine directive 2006/42/EC and Ecodesign Directive 2009/125/EC.
  • Mechanical protection standards according to EN ISO 12499 and turbine balancing as per ISO 1940.

Standard ATEX Fan Heater and Convector Specifications:
  • Fan heaters range from 6 kW to 22.5 kW with varying air flow and motor power specifications.
  • Convectors range from 500 W to 3000 W with specific voltage and weight details.
See more

Catalog excerpts

ATEX industrial fan heater-1

ATEX INDUSTRIAL FAN HEATERS ATEX Industrial fan heaters for space heating in explosive atmosphere gas (areas 1 or 2) or dust (areas 21 or 22). 1. Features  1 Cable gland ATEX II 2GD (Power).  1 Cable gland ATEX II 2GD (Safety Thermostat).  Motor fan series EVXP ATEX.  Voltage Three Phase 230/400V 50Hz.  Safety thermostat with manual reset.  Galvanized screws.  Galvanized Steel Sheet Metal.  Battery electric heater ATEX certified by a notified body. 2. Temperature of transported fluid  Temperature from -20°C up to +40°C. 3. Ambient temperature  Temperature from -20°C up to +40°C. 4. Options  Other power (up to 60 kW).  Other ATEX classification : Gas Versions : II 2G Ex d IIC T1 à T4 .  Dust Versions : II 2D ExtD A21 IP6X T140°C, 210°C, 310°C ou 460°C.  ATEX control panels pre-wired.  Construction with centrifugal fan.  Special Voltage and frequency.  Construction with stainless steel sheet metal, screws and stainless steel smooth or finned heater tubes. 5. Remark  For heaters versions GD, the maximum surface temperatures for dust areas are downgraded 5°C for T4 and 10°C for T3. 6. Standards  Each fan is tested in operation with vibration control in accordance with ISO 14964.  All fans are in accordance with the machine directive 2006/42/EC (as "partly completed machinery") and Directive 2009/125/EC Ecodesign “ERP” (Regulation n°327/2011).  Safety requirements for mechanical protections according to EN ISO 12499  The turbines are balanced according to ISO 1940 (standard class G6.3) Resistencias Tope,S.A·C/Josep Ros i Ros 57·Sant Andreu de la Barca· Barcelona· SPAIN· Phone:+34 93

 Open the catalog to page 1
ATEX industrial fan heater-2

LID OF JUNCTION BOX GRILLE WITH STEERABLE FINS JUNCTION BOX SHEATH FOR THERMOWEL DUCT HEATER List of standar ATEX fan heater Power (KW) Motor power Resistencias Tope,S.A·C/Josep Ros i Ros 57·Sant Andreu de la Barca· Barcelona· SPAIN· Phone:+34 932 650 246 www.resistenciastope.com·export@resistenciastope

 Open the catalog to page 2
ATEX industrial fan heater-3

ATEX Industrial convectors for space heating in explosive atmosphere gas (areas 1 or 2) or dust (areas 21 or 22). 1. Features  Certificate LCIE 03 ATEX 6386 X.  1 Cable gland ATEX II 2GD EExd IIC.  Type protection Eexd IIC T3.  Single phase 230V or three phase 230/400V 50Hz.  Painted support (x2).  Case in painted perforated sheet.  Casted in aluminium junction box. 2. Ambient temperature  Temperature from -20°C up to +60°C. 3. Temperature of transport fluid.  Temperature from -20°C up to +60°C. 4. Opctions  Thermostat control +6 / +38°C with thermowell in stainless steel 304 and 1...

 Open the catalog to page 3
ATEX industrial fan heater-4

List of standar ATEX convector Power (W) Resistencias Tope,S.A·C/Josep Ros i Ros 57·Sant Andreu de la Barca· Barcelona· SPAIN· Phone:+34 932 650 246 www.resistenciastope.com·export@resistencia

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.