Introduction
This manual provides comprehensive instructions for the RESI-MBUSxLVL-ETH device by RESI Informatik & Automation GmbH, covering installation, configuration, and operation. It is proprietary and confidential.

Important Security Notes
Only qualified personnel should handle the device, ensuring it is disconnected from power during installation. Compliance with electrical standards and EMC regulations is mandatory. Unauthorized modifications void warranties.

General Information
The manual includes technical data, mounting instructions, and connection guidelines, emphasizing adherence to instructions for optimal functionality.

Technical Specifications
Details include dimensions and operational parameters, supported by a 3D drawing for reference.

Mounting and Connections
Instructions cover device assembly, DIP switch settings, and wiring, with a wiring diagram provided.

Operation Modes
Describes various operation modes, including configuration via web interface and Ethernet.

Configuration
Guidelines for IP address setup, socket number changes, and serial MBUS interface configuration are included, with ASCII commands and Modbus register tables for advanced settings.

Software Configuration
Details on using Modbus Doctor software for device configuration.

RESI-MBUSxLVL-ETH Web Configuration

Overview:
Instructions for configuring gateways with a built-in web server for Ethernet interface. Standard IP settings and default credentials are provided.

IP Address Setup:
Navigate to 'Local IP Config' for static IP or DHCP settings. Save changes and reboot for effect. Factory reset available for troubleshooting.

Socket Number Configuration:
Set socket number on 'TTL1' page. Default is 1024, with 502 for MODBUS/TCP. Avoid altering other parameters.

User Credentials and Module Name:
Update module name, username, and password on 'Misc config' page. Save changes.

Module Restart:
Restart via Ethernet on 'Reboot' page.

Serial MBUS Interface Configuration:
Configure using MODBUS/RTU, MODBUS/TCP, or ASCII commands. ASCII command table provided.

MODBUS Holding Register Table:
Details holding registers for serial MBUS line configuration. Standard unit ID is 254, changeable via special register.

Specifications
  • Dimensions: 35.8 x 90 x 58 mm.
  • Weight: 90 grams.
  • Color: Grey (RAL7035).
  • Material: PA - UL 94 V0, flame retardant.
  • Protection Class: IP20, protection against solid objects larger than 12.5 mm.
Illustrations
  • Dimension Illustration: Visual representation in millimeters.
  • 3D Drawing: Three-dimensional view of the housing.
See more

Catalog excerpts

RESI-MBUSxLVL-ETH -1

. Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . . Weitergabe sowie Ver vielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdr ücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung. . Great care has been taken in the creation of the text, illustrations and program examples in this manual. The editors and publishers accept no responsibility for any inadvertent omission of entries or for typographical or other errors herein. Nor can they be held responsible or liable for consequences arising from any errors herein. This manual is subject to copyright law. All rights are reserved. This manual may not be copied in part or whole in any form including electronic media without the written consent of RESI. Neither may it be transferred in any other language suitable for machines or data processing facilities. Also rights for reproduction through lecture, radio or television transmission are reserved. This documentation and the accompanying software are copyrighted by RESI. © Copyright 2005 – 2020 by RESI Informatik & Automation GmbH RESI Informatik & Automation GmbH Date: Version: Edited by: Great care has been taken in the creation of the text, illustrations and program examples in this manual. The editors and publishers accept no responsibility for any inadvertent omission of entries or for Pages Client: 05.10.2020 typographical or other errors herein. Nor can they be held responsible 1.0 or liable for consequences arising from any errors herein. Title: RESI-MBUSxLVL-ETH Manual DI HC Sigl,MSc This manual is subject to copyright law. All rights are reserved. This manual may not be copied in part or whole in any form including electronic media without the written consent of RESI. Neither may i

 Open the catalog to page 1
RESI-MBUSxLVL-ETH -2

. Weitergabe sowie Ver vielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdr ücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung. . . Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . RESI-MBUSxLVL-ETH Manual Description Initial...

 Open the catalog to page 2
RESI-MBUSxLVL-ETH -3

RESI® 2 Content . Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . . Weitergabe sowie Ver vielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdr ücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung. . RESI-MBUSxLVL-ETH Manual

 Open the catalog to page 3
RESI-MBUSxLVL-ETH -4

. Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . 3 IMPORTANT SECURITY NOTES Danger to life through electrical current! Only skilled personal trained in electro-engineering should perform the described steps in the following chapters. Please observe the country specific rules and standards. Do not perform any electrical work while the device is connected to power. Pay attention to the...

 Open the catalog to page 4
RESI-MBUSxLVL-ETH -5

RESI®  The information on our homepage, in our datasheets, in our manuals, in our catalogues or published by our partners can deviate from the product documentation and is not necessarily always actual, due to constant improvement of our products for technical progress! . Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. .  In case of modification of our devices made by the user, all warranty...

 Open the catalog to page 5
RESI-MBUSxLVL-ETH -6

RESI®4 General Information The RESI-MBUSxLVL-ETH gateways are designed for integrating MBUS smart meters via Ethernet interface into an own building automation or industrial solution with a host system, which is able to interpret the MBUS standard protocol. The converters offer the following features: • RESI-MBUSxLVL-ETH: Serial communication with MBUS smart meters with 300-57600baud, even parity, 1 stop bit. • Different versions of gateways for individual situations: • RESI-MBUS24LVL-ETH: Gateway for maximum of 24 MBUS meters • RESI-MBUS48LVL-ETH: Gateway for maximum of 48 MBUS meters • RESI-MBUS64LVL-ETH:...

 Open the catalog to page 6
RESI-MBUSxLVL-ETH -7

. Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . Technical data for RESI-MBUSxLVL-ETH Technical Data Power supply Supply voltage Power LED Power consumption Serial interface Protocol Type Baud rates . Weitergabe sowie Ver vielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdr ücklich zugestanden. Zuwiderhandlungen verpflichten zu...

 Open the catalog to page 7
RESI-MBUSxLVL-ETH -8

. Weitergabe sowie Ver vielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdr ücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung. . . Proprietary data, company confidential. All rights reserved. Confié à titre de secret d'entreprise. Tous droits réservés. Comunicado como segredo empresarial. Reservados todos os direitos. Confidado como secreto industrial. Nos reservamos todos los derechos. . Our RESI-MBUSxLVL-ETH converters are designed...

 Open the catalog to page 8

All RESI catalogs and technical brochures

  1. RESI-KNX-xxx

    1  Page

  2. GATEWAYS

    122  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.