1. Catalogs
  2. Republic Manufacturing
  3. HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz

HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz

HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz

HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz

Product catalog summary
Overview
Republic offers a comprehensive range of regenerative blowers suitable for high vacuum or compressed air applications, available in both horizontal and vertical mounting positions. These blowers feature TEFC motors that are certified for 50/60 Hz operation and meet cUL, UL, and CE standards. The design ensures powerful air force with minimal friction, and the bearings are positioned outside the compression chamber for enhanced reliability under high differential pressure. The blowers are low-maintenance and oil-free, providing continuous and dependable service.

Performance Specifications
The performance curves are based on air at 59°F and atmospheric pressure of 29.91 inch Hg, with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77°F. Suction capacity is related to inlet conditions, while pressure capacity is related to atmospheric conditions. For conditions outside these parameters, Republic should be contacted. Motor tolerances for three-phase motors are +/-10% for fixed voltage and +/-5% for voltage range motors, while single-phase machines have a +/-5% tolerance. Frequency tolerance is +/-2% maximum.

Model Specifications
  • HRC 300: Three-phase, 50/60 Hz, air flow of 124/210 CFM/m³/hr, rated vacuum of 80/200 in. H2O/mbar, rated pressure of 76/190 in. H2O/mbar, motor power of 2.1/1.6 HP/kW, voltage range of 200-275 r/345-415 Y, sound level of 64 dB, weight of 51/23 lb/kg.
  • HRC 400: Three-phase, 50/60 Hz, air flow of 124/210 CFM/m³/hr, rated vacuum of 88/220 in. H2O/mbar, rated pressure of 108/270 in. H2O/mbar, motor power of 3.0/2.2 HP/kW, voltage range of 200-275 r/345-415 Y, sound level of 64 dB, weight of 57/26 lb/kg.
  • HRC 301: Single-phase, 50/60 Hz, air flow of 124/210 CFM/m³/hr, rated vacuum of 65/161 in. H2O/mbar, rated pressure of 65/161 in. H2O/mbar, motor power of 2.0/1.5 HP/kW, voltage of 230 V, sound level of 64 dB, weight of 53/24 lb/kg.
  • HRC 401: Single-phase, 50/60 Hz, air flow of 124/210 CFM/m³/hr, rated vacuum of 88/220 in. H2O/mbar, rated pressure of 84/210 in. H2O/mbar, motor power of 2.5/1.9 HP/kW, voltage of 230 V, sound level of 64 dB, weight of 57/26 lb/kg.

Available Options
Republic offers pre-assembled kits for pressure or vacuum applications, including an inlet filter, gauge, and relief valve, all factory tested before shipment. Optional items include check valves, tube adaptors, washdown motors, explosion-proof motors, noise enclosures, and control panels such as VFDs, PLCs, or starter panels.

Dimensions
All models (HRC 300, 400, 301, 401) share the same dimensions: 13.15 in (334 mm) length, 14.69 in (373 mm) width, and various other detailed measurements provided for installation purposes.
See more

Catalog excerpts

HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz-1

Republic offers a complete line of regenerative blowers for high vacuum or compressed air applications in both horizontal and vertical mounted positions. TEFC motors are rated for 50/60 Hz operation and are cUL, UL, and CE certified. The impeller is directly connected to the motor shaft, providing powerful air force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. This low-maintenance, oil-free design provides continuous, dependable service to our customers. PERFORMANCE Vacuum Total Pressure Difference Pressure The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of 29.91 inch Hg with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 oF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/-5% tolerance. The frequency tolerance is +/-2% maximum. ©Republic Manufacturing

 Open the catalog to page 1
HRC301, 210 m3/hr, 3 Phase/ 1 Phase, 50Hz-2

Available Options All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. VACUUM KIT PRESSURE KIT Check Valvev ^Adapter Check Valve JUEPUBLIC * ** .MANUFACTURING 5131 Cash Road, Dallas, TX 75247, USA 800.847.0380 • [email protected]...

 Open the catalog to page 2

All Republic Manufacturing catalogs and technical brochures

Archived catalogs

  1. 4RB610

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.