Compressed air treatment
17Pages

{{requestButtons}}

Catalog excerpts

Compressed air treatment - 1

Compressed air quality made to measure Sketch made with RENNER Planner Software – available to RENNER distributors on request Cyclone separators / Air filters / Condensate drains / Refrigeration dryers / Oil-water separators

Open the catalog to page 1
Compressed air treatment - 2

Compressed air treatment and accessories Compressed air is used in almost all industrial sectors. The demands on their quality and purity vary depending on the application. RENNER offers the right products and solutions for all requirements. Cyclone separator Condensate drain Condensate is separated at the compressed air outlet of the compressor In different filtration classes according to ISO 8573:1 for clean compressed air Discharge of condensate without unnecessary compressed air losses Refrigeration dryer Adsorption dryer Adsorption dryer Protection against condensation Clean and dry...

Open the catalog to page 2
Compressed air treatment - 3

Cyclone separator RF-C 0050 - 1500 for separating larger amounts of condensate and coarse dirt particles with level-controlled condensate drain Through centrifugal separation of liquids from compressed air of up to 99%, Cyclone separators extract water and coarse dirt particles from compressed air by means of the centrifugal effect and are installed directly behind the compressor. The incorporated deflector plate creates a spinning movement resulting in a cyclone-like, upward stream of compressed air inside the enclosure. The special design of the lower section of the filter enclosure, and...

Open the catalog to page 3
Compressed air treatment - 4

RENNER air filters RF 0035 - 1500 product range RF = with thread with automatic condensate drain max. operating pressure 16 bar RENNER compressed air filters are suitable for separating oil and water aerosols as well for the removal of solid contaminants from compressed air. Even dust is securely kept on the surface and in the filter material. A filtration efficiency of almost 100 percent is reached through the use of various filtration mechanisms, such as separation by direct trapping, inertial impact and Brownian motion. The standard filter is fitted with a mechanically controlled steam...

Open the catalog to page 4
Compressed air treatment - 6

Condensate drain UFM-D03 - 130 / UFM-P level-controlled condensate drain without pressure loss pneumatic level-controlled condensate drain All condensers and refrigeration dryers produce condensate that must be drained off safely. A reliable condensate drain is therefore an important part of compressed air treatment. The condensate flows into the steam trap via the intake line (1) and collects in the enclosure (2). A capacitive sensor (3) continuously records the fill level and signals the electronic controller as soon as the tank is full. The pilot valve (4) is activated and the membrane...

Open the catalog to page 6
Compressed air treatment - 7

Three-stages-filter RF-T 0050 - 0110 / DF-T 0050 - 0110 creating oil-free compressed air composed of a sub-micro coalescent filter stage, an active carbon filter stage and a high efficient particle filter (air quality class 1 according to ISO 8573-1:2010) all with thread, economizer and automatic condensate drain KA /", max. operating pressure 16 bar The Economizer (differential pressure indicator) If you replace a used filter element at the right time, you save money! The economizer determines the most economical time to do this as it continuously measures the differential pressure. The...

Open the catalog to page 7
Compressed air treatment - 8

Refrigeration dryer RKT-CQ 0020 - 0850 AB stand-alone unit, can not be mounted to RENNER compressors with electronic control and time controlled or level-controlled condensate drain The electronic control of the refrigeration dryer The electronic DDS3 control is a micro-control specially developed for compressed air dryers with the following functions: Corrected dryer performance: Volume flow at entry (f x f x f x f,.) p ti ta tpd'

Open the catalog to page 8
Compressed air treatment - 9

Refrigeration dryer RKT+ 0035 - 0450 for mounting at RENNER compressors with electronic control and time controlled or level-controlled condensate drain The dryer has a cooling system that cools down the compressed air. In this process, the water vapour saturation limit is lowered resulting in condensate that is removed by the condensate drain. The greater the cooling temperature differential of the compressed air, the higher the condensed water volume. The lower the cooling temperature of the compressed air, the lower the moisture content. The lower limit of the compressed air cooling...

Open the catalog to page 9
Compressed air treatment - 10

Cyclone separator 2x filter incl. filter element Cyclone separator Cyclone separator Cyclone separator Filter packages Refrigeration dryer* Refrigeration dryer* Refrigeration dryer* RKT-CQ / RKT+* 2x filter incl. filter element Micro filter 3x filter incl. filter element RF-V 1100 Superplus + RF-S 1100 Standard + RF-A 1100 Standard RF-V 0750 Superplus + RF-S 0750 Standard + RF-A 0750 Standard RF-V 0600 Superplus + RF-S 0600 Standard + RF-A 0600 Standard RF-V 0450 Superplus + RF-S 0450 Standard + RF-A 0450 Standard RF-V 0320 Superplus + RF-S 0320 Standard + RF-A 0320 Standard RF-V 0210...

Open the catalog to page 10
Compressed air treatment - 11

Refrigeration dryer DC 1000 + 1175 AES / DV 1260 - 2000 AB / DV 1260 - 2000 AVS DC 1000 + 1175 AES with energy saving control unit DV 1260 - 2000 AB with hot gas bypass control DV 1260 - 2000 AVS with variable speed control stand-alone unit, all with micro processor control and level-controlled condensate drain Volume flow at entry (f x f x f x f .) p ti ta tpd

Open the catalog to page 11
Compressed air treatment - 12

Adsorption dryer 0005 - 0100 Superplus compressed air treatment system with heatless regenerating adsorption dryer with integrated pre- and afterfilter dew point -40°C, according to ISO 8573-1:2010 The cold-regenerating adsorption dryers of the RUP series are a comprehensive air treatment system with integrated pre- and after-filter as well as an automatic condensate drain. All mechanical and electronic components are integrated in a unique and compact multifunction block. This allows easy maintenance in a small space. Convenient desiccant cartridges simplify storage, transport and...

Open the catalog to page 12
Compressed air treatment - 13

Adsorption dryers RAT-40 0100 - 1650 compressed air treatment system with heatless regenerating adsorption dryer with integrated pre- and afterfilter dew point -40°C (RAT-70 with dew point -70°C on request) according to ISO 8573-1:2010 Adsorption drying is a physical process in which water vapour is bound to a desiccant. Adsorption dryers are typically built with two drying vessels to regularly regenerate the desiccant so it regains its drying capacity. The first vessel dries the incoming compressed air while the second vessel is being regenerated. Each vessel switches tasks when the other...

Open the catalog to page 13

All RENNER Kompressoren catalogs and technical brochures

  1. RSW / RSWF

    8 Pages

  2. RS-B

    5 Pages

  3. RS-H series