1. Catalogs
  2. RENISHAW
  3. RSP3-6 extended reach probe

RSP3-6 extended reach probe
1 /4Pages

RSP3-6 extended reach probe

RSP3-6 extended reach probe
1 /4Pages

Catalog excerpts

RSP3-6 extended reach probe-1

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom RSP3-6 extended reach probe Enhanced access and inspection capability with RSP3-6 RSP3-6 Key benefits Reach Available with straight extensions up to 800 mm from REVO’s A-axis centre of rotation, and cranked extensions up to 600 mm from REVO’s A-axis centre of rotation. Accuracy Scanning accuracy: Typically better than 10 µm form error (filtered) and 5 µm diameter error Touch-trigger accuracy: Typically better than 3 µm form and diameter error Part of the REVO 5-axis multi-sensor system Long extensions combined with 5-axis movements for better part access, and multi-sensor changing for increased flexibility. The other RSP3 probes within the range (RSP3-1, -2, -3, -4) can be used for 3-axis scanning with fixed REVO head angles during measurement, providing the REVO system with 3D-scanning (X, Y, Z) with crank stylus capabilities. It also allows different lengths of styli to be used whilst maintaining optimum metrology performance. The RSP3-6 provides enhanced capability for accessing deep bores and inspecting features within large parts. It is available with a range of stylus holders for applications requiring straight and cranked extensions and can be used for both touch-trigger and 2D scanning applic

 Open the catalog to page 1
RSP3-6 extended reach probe-2

Performance Scanning of a ring gauge REVO A-axis centre of rotation Form error (F) and diameter error (D) Test setup criteria Stylus used Renishaw’s M2 stylus range Data filter used Harmonic simple cut off order = 60 UPR (undulation values) Artefacts used Ø45 mm (nom) calibration sphere (for the calibration) Ø50 mm (nom) ring gauge (for the ring gauge tests) 5 mm/s (for the ring gauge scan tests) Touch speed 2 mm/s (for the ring gauge touch tests) Bi-directional scans Bi-directional scan data is quoted to demonstrate the performance of the Renishaw probe calibration method Scanning speed

 Open the catalog to page 2
RSP3-6 extended reach probe-3

Touch-trigger probing of a ring gauge Form error (F) and diameter error (D) EWL = effective working length

 Open the catalog to page 3
RSP3-6 extended reach probe-4

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom REVO A-axis centre of rotation Measurement range ±0.5 mm deflection in all directions in all orientations X, Y +Z Overtravel range 300 g (10.58 oz) (excluding stylus holder and stylus) RSP3-6 + RSH3-6c-500 EWL 348 mm (13.70 in) RSP3-6 + RSH3-6c-600 EWL 448 mm (17.64 in) Effective stylus length range Using M2 star centre Using 10 mm stylus RSP3-6 + RSH3-6c-500 50 mm (8 g) * Maximum permissible stylus Mounting Crash protection Magnetised kinematic coupling ±X, ±Y, ­ Z - Via break out of probe or stylus holder Via...

 Open the catalog to page 4

All RENISHAW catalogs and technical brochures

  1. QC20 ballbar

    16  Pages

  2. RTP20

    2  Pages

  3. PH10M-iQ PLUS

    2  Pages

  4. RLMD01_09

    13  Pages

  5. RLBD01_04

    9  Pages

  6. RLCD03_03

    9  Pages

  7. HiLin™

    20  Pages

  8. SP80

    4  Pages

  9. SP600

    4  Pages

  10. Precision styli

    60  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.