1. Catalogs
  2. RENISHAW
  3. REVO-2 and RSP2 probes

REVO-2 and RSP2 probes

REVO-2 and RSP2 probes

REVO-2 and RSP2 probes

Product catalog summary
Overview of REVO-2 and RSP2 Probes
The REVO-2 dynamic measuring system is engineered to enhance measurement throughput while maintaining high accuracy. It is the sole scanning system for Coordinate Measuring Machines (CMMs) that simultaneously manages the motion of three machine and two head axes, collecting data with 2D and 3D tactile probes, a surface roughness measurement probe, and a non-contact vision probe. The system's design includes advanced laser measurement and electrical signal transmission technology, allowing precise measurements at high data capture rates. The 5-axis control system minimizes dynamic errors from machine movement, as the lighter and more dynamic measuring head performs most of the work.

RSP2 Probe Features
The RSP2 is a lightweight probe designed for REVO systems, capable of 2D scanning and 3D touch-trigger measurement. It features a universal body compatible with various stylus holders, ranging from 175 mm to 500 mm in reach. Renishaw's tip-sensing technology is utilized for high-speed scanning with low forces and minimal stylus wear. The UCCserver software manages stylus compatibility to ensure optimal performance.

Specifications of REVO-2
  • Scan speed: Up to 500 mm/sec
  • Data collection rate: Up to 4000 points/sec
  • Operating temperature: +10 °C to +40 °C
  • Storage temperature: -25 °C to +70 °C
  • Weight: 2.1 kg
  • Height: 176.5 mm
  • B-axis dimensions: 92 mm × 93 mm
  • A-axis swept diameter: 116 mm
  • Movement speed: 3 revs/sec
  • A-axis rotation: -5° to +120°
  • B-axis rotation: Continuous
  • Angular resolution: 0.02 arc sec
  • Air bearings consumption: Up to 50 l/min

Probe Comparison
The document includes a comparison chart for various probes (RSP2, RSP3, SFP1, RVP) detailing features like tip sensing, non-contact capabilities, head scanning, and automatic changing systems.

Additional Information
The RCP TC-2 is used for changing RSP2 probes, while the RCP2 is for changing RSP2 stylus holders. For further contact details, visit Renishaw's website. The document emphasizes that while efforts have been made to ensure accuracy, Renishaw excludes liability for any inaccuracies.
See more

Catalog excerpts

REVO-2 and RSP2 probes-1

The REVO-2 dynamic measuring system is designed to maximise measurement throughput whilst maintaining high system accuracy. REVO-2 is the only scanning system for CMMs that simultaneously controls the motion of three machine and two head axes whilst collecting work piece data using its range of 2D and 3D tactile probes, surface roughness measurement probe and now non-contact vision probe too. The head’s design incorporates sophisticated laser measurement and electrical signal transmission technology for precise work piece measurement at extremely high rates of data capture. The 5-axis control system removes unwanted dynamic errors associated with machine movement because the measuring head performs most of the work. As the head is much lighter and more dynamic than the CMM, it is able to quickly follow changes in the part geometry without introducing large dynamic errors. RSP2 is a dedicated lightweight probe for use on REVO systems, capable of 2D-scanning (x, y) and 3D touch-trigger measurement (x, y, z). The RSP2 has a universal body to which a number of different length stylus holders, with a minimum reach of 175 mm* and a maximum reach of 500 mm*, can be fitted. The RSP2 utilises Renishaw’s tip-sensing technology, specifically designed for high speed scanning with low scanning forces and minimal stylus wear. The UCCserver software manages the type of stylus that can be used with RSP2, ensuring that optimal metrology performance is achieved. RSH450 *The number behind RSH represents length from head centre of rotation to stylus ball centre when carrying a 10 mm stylus.

 Open the catalog to page 1
REVO-2 and RSP2 probes-2

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom RSP2 and RSH# changing system The RCP TC-2 (thermally controlled REVO change port) is used for changing RSP2, whereas the RCP2 (REVO change port) is configured to change RSP2 stylus holders (RSH175, RSH250, RSH350, RSH450 and RSH500). REVO-2 specification Scan speed Data collection rate Operating temperature Storage temperature Weight (excluding probe and cables) Height (overall) 176.5 mm (6.95 in). Quill to probe mount, including 4 mm mounting plate B-axis dimensions A-axis swept diameter Movement speed A-axis...

 Open the catalog to page 2

All RENISHAW catalogs and technical brochures

  1. QC20 ballbar

    16  Pages

  2. RTP20

    2  Pages

  3. PH10M-iQ PLUS

    2  Pages

  4. RLMD01_09

    13  Pages

  5. RLBD01_04

    9  Pages

  6. RLCD03_03

    9  Pages

  7. HiLin™

    20  Pages

  8. SP80

    4  Pages

  9. SP600

    4  Pages

  10. Precision styli

    60  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.