STATIONARY HOT AIR HEATING SYSTEMS Rapid heat, adapted to your needs Stationary heaters Wall-mounted heaters Universal heaters Hot water heaters Ceiling ventilation units Ceiling heating systems Ceiling fans Exhaust gas systems
Open the catalog to page 1Efficient wall heaters with modulating gas burner REMKO GPS SERIES Hall heating with high energy efficiency The REMKO series is characterised by their compact dimensions, flexible application possibilities, and particularly by their microprocessor controlled gas burner technology. A total of 5 unit sizes with a heating capacity from 10.0 to 73.5 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible installation possibility of this series of units. The use of modulating gas burner technology achieves...
Open the catalog to page 2Suitable accessories at www.remko.de/en Technical data Device type Nominal heat load Nominal heat power Air flow rate Fuel Fuel consumption, natural gas H Fuel consumption, natural gas L Fuel consumption, liquid gas Power supply Space heating seasonal performance factor Exhaust connection Ø Combustion air connection Ø Weight Natural gas H version EDV-Nr. Natural gas L version EDV-Nr. Propane version EDV-Nr. Note: The gas connection must be performed by a licensed installer. Calorific value Hi related to dry standard test gas at 15°C and 1,013.25 mbar Natural gas H G 20 = 9.45 kWh/m³ propane gas...
Open the catalog to page 3Wall-mounted calorific value heating systems with modulating gas burner in a condensing design REMKO GPC SERIES Hall heating with the highest energy efficiency The REMKO series is characterised by their compact dimensions, flexible application possibilities, and particularly by their microprocessor controlled gas burner technology. A total of four unit sizes with a heating capacity from 5.4 to 82.0 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible installation possibility of this series of units....
Open the catalog to page 4Suitable accessories at www.remko.de/en Technical data Device type Nominal heat load Nominal heat power Air flow rate Max. condensate Fuel Fuel consumption, natural gas H Fuel consumption, natural gas L Fuel consumption, liquid gas Power supply Space heating seasonal performance factor Exhaust connection Ø Combustion air connection Ø Weight Natural gas H version EDV-Nr. Natural gas L version EDV-Nr. Propane version EDV-Nr. Note: The gas connection must be made by a licenced installer * The flue gas and fresh air diameter is achieved using an adapter supplied as standard
Open the catalog to page 5Efficient universal heating systems in a planning-oriented modular system for oil and gas combustion REMKO VRS EN Horizontal design REMKO VRS EN SERIES Rapid heat, adapted to your needs For economical heating in industrial halls and warehouses, workshops, sports centres and exhibition halls, or glass and plastic film greenhouses, these REMKO heaters are incomparable. Whether you use EL heating oil, propane or natural gas, VRS EN heaters always generate the heat you need: quickly, safely, and economically. In contrast with conventional hot water heating systems, these heaters function without...
Open the catalog to page 6Suitable accessories at www.remko.de/en Technical data Device type Nominal heat load 1) Nominal heat power Air flow rate 2) Fuel Fuel consumption, natural gas H Fuel consumption, natural gas L Fuel consumption, liquid gas Fuel consumption, heating oil Exhaust gas mass flow (HEL) 5) Exhaust gas temperature, approx. 6) Max. exhaust gas loss Flue-gas-side resistance Power supply Max. power consumption Nominal current consumption max. Utilization efficiency for nominal heat output Utilization efficiency for minimum performance Efficiency heat emission Space heating seasonal performance factor Exhaust...
Open the catalog to page 7Universal calorific value heating systems in a planning-oriented modular system for oil and gas combustion Radial fan with EC motor Low-emission blue flame burner Fast heat, low emissions with high energy efficiency Space-saving installation with low mounting effort This REMKO series is characterised by a combination of extremely advanced technologies. Due to the newly developed design of the combustion chamber and heat exchanger and the use of state-ofthe-art blue flame burner technology and EC fans, the VRS-C automatic heaters set new standards in hall heating. Through consistent use of the...
Open the catalog to page 8Suitable accessories at www.remko.de/en Technical data Device type Nominal heat load 1) Nominal heat power Air flow rate 2) Fuel Fuel consumption, natural gas H Fuel consumption, natural gas L Fuel consumption, liquid gas Fuel consumption, heating oil Exhaust gas temperature, approx. 6) Flue-gas-side resistance Power supply Max. power consumption Nominal current consumption max. Utilization efficiency for nominal heat output 1) Utilization efficiency for minimum performance 1) Efficiency heat emission Space heating seasonal performance factor Exhaust connection Ø Weight 7) Related to calorific...
Open the catalog to page 9Hot water heaters in low-temperature design with EC fan for heating REMKO PWN H SERIES The efficient heating system for warehouses and supermarkets High-quality plastic housing for industrial applications The PWN H hot water heaters are optimally suited for use in commercial applications due to their high-quality, robust plastic housing. Through the universal colouring of the devices, they fit in discreetly in almost every environment. Discreet design Modern, efficient EC technology Versatile mounting possibilities using series-standard bracket Thanks to the modern, energy-efficient EC motors,...
Open the catalog to page 10Suitable accessories at www.remko.de/en Technical data Device type Heating capacity at 70/50 and 15°C air intake Heating capacity at 55/45 and 15°C air intake Cooling capacity for 7/12 and 27°C air inlet 3) Air flow rate Nominal flow rate, heating medium 1) Nominal flow rate, coolant 3) Throw Power supply Max. power consumption Nominal current consumption max. Connection Heating medium temperature Max. operating pressure Nominal pressure drop, internal heating Nominal pressure drop, internal, cooling Sound pressure level at 1.5m distance 4) Dimensions H/W/D Weight Ref. no. Water inlet temp. 70°C,...
Open the catalog to page 1148 Pages
40 Pages
28 Pages
4 Pages
24 Pages
12 Pages
52 Pages
4 Pages
4 Pages
16 Pages
12 Pages
8 Pages
32 Pages
28 Pages
40 Pages
8 Pages
52 Pages
4 Pages
28 Pages
24 Pages