Product catalog summary
Overview: This document provides technical specifications and guidelines for the RLK series of control lamps manufactured by Relpol S.A. These lamps are used for optical signaling of voltage presence in electrical networks.
Single-Phase Control Lamps (RLK-1 Series):
  • Models: RLK-1G (green LED), RLK-1R (red LED), RLK-1Y (yellow LED).
  • Specifications: Operates on AC/DC with a supply voltage of 130-260 V AC at 50/60 Hz. Rated power consumption is ≤ 0.7 W. Operating temperature ranges from -20 to +55 °C.
  • Dimensions: 90(98.8) x 17.5 x 64.5 mm.
  • Connection: Uses screw terminals. Requires additional fuse protection if connected to a circuit breaker of 25 A or more.
Three-Phase Control Lamps (RLK-3 Series):
  • Models: RLK-3G (green LEDs), RLK-3R (red LEDs), RLK-3K (red, yellow, green LEDs).
  • Specifications: Operates on AC with a supply voltage of 3(N)~ 400/230 V at 50/60 Hz. Rated power consumption is ≤ 1.1 W. Operating temperature ranges from -20 to +55 °C.
  • Dimensions: 90(98.8) x 17.5 x 64.5 mm.
  • Connection: Uses screw terminals. Requires additional fuse protection if connected to a circuit breaker of 25 A or more.
Standards and Applications: Both series comply with PN-EN 62094-1 and PN-EN 61000 standards, suitable for low-voltage systems.
Precautions:
  • Ensure product parameters provide a safety margin and do not exceed specified limits.
  • Avoid touching live parts and ensure correct connection to prevent malfunctions or fire risks.
  • Design systems with double safety measures for critical applications.
Additional Products Offered by Relpol S.A.:
  • Subminiature, miniature, industrial, interface, programmable, time, monitoring, and railroad industry relays.
  • Plug-in sockets, installation contactors, power supplies, overvoltage arresters, solid state relays, protection relays, and radiation portal monitors.
See more

Catalog excerpts

Signal Lamps-2

► single-phase control lamps - modular covers RLK-1. PN-EN 62094-1, PN-EN 61000-4-2,3,4,5,6,11, « applications: in low-voltage systems Indicator (colors of LEDs) © Supply voltage AC/DC Rated power consumption Ambient temperature Dimensions mm AC: 50/60 Hz: 130...260 V DC: < 0,7 W operating: -20...+55 °C 90(98,8) x 17,5 x 64,5 © screw terminals © Self-operating control lamps - optic signaling of AC/DC voltage presence in single-phase network (lighting of one non-replaceable LED in the center of the face panel) © In the bracket the length with 35 mm rail taps is shown connection diagram Single-phase...

 Open the catalog to page 2
Signal Lamps-3

► three-phase control lamps - modular covers RLK-3. applications: in low-voltage systems RLK-3G Indicator (colors of LEDs) © 3x green Supply voltage AC Rated power consumption Ambient temperature Dimensions mm © Self-operating control lamps - optic signaling of AC voltage presence in three-phase network - 3(N)~ 400/230 V (lighting of three non-replaceable LEDs in the center of the face panel) © In the bracket the length with 35 mm rail taps is shown connection diagram three-phase lamps description Three-phase network © © In case an overcurrent circuit breaker of 25 A or more is installed before...

 Open the catalog to page 3
Signal Lamps-4

The offer of Relpol S.A. includes the following products: subminiature signal relays rated switching capacity: from 0,5 A to 3 A, coil voltage range: from 3 V to 48 V DC miniature relays rated switching capacity: from 5 A to 20 A industrial relays rated switching capacity: from 5 A to 48 A, mounting: to plug-in sockets on 35 mm rail mount acc. to PN-EN 60715 or on panel mounting, for PCB interface relays rated switching capacity: from 0,05 A to 16 A, number of contacts: from 1 to 4 programmable relays versions: 8 inputs / 4 outputs, 16 inputs / 8 outputs, with LCD display, without display, supply...

 Open the catalog to page 4

All RELPOL catalogs and technical brochures

  1. Catalogue 2021

    106  Pages

  2. Time relays

    4  Pages

  3. MR-GU1M2P-TR2

    4  Pages

  4. RSR20

    4  Pages

  5. RSR30

    5  Pages

  6. RSR40

    3  Pages

  7. RSR50

    10  Pages

  8. RLK-1

    2  Pages

  9. RLK-3

    2  Pages

  10. Contactors

    16  Pages

  11. RZI60-24-P

    3  Pages

  12. Time relays

    12  Pages

  13. RM12N

    3  Pages

  14. MT-W...M

    7  Pages

  15. R2N, R3N, R4N

    4  Pages

  16. R40N

    3  Pages

  17. R30N

    3  Pages

  18. RSM822

    3  Pages

Archived catalogs

  1. Contactors

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.