Catalog excerpts
Output circuit - contact data Multifunctions monitoring relays (DC and AC voltage monitoring in 1-phase network, with adjustable thresholds) Fault latch mode • Timing adjustment of start-up suppression and tripping delay © • Supply via TR2 supply transformer © • Frequency of supply voltage: 16,6...400 Hz • Output: 2 CO (2 changeover contacts) Industrial cover, width 22,5 mm Direct mounting on 35 mm rail mount acc. to PN-EN 60715 Recognitions, certifications, directives: cc Number and type of contacts © Separately adjustable (two adjusting knobs). © Supply voltage depending on the TR2 transformer which shall be ordered as a separate product - see page 4. © If the distance between the mounting relays is less than 5 mm. © If the distance between the mounting relays is greater than 5 mm. © Indication of relay status - according to the set threshold. www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl
Open the catalog to page 1MR-GU1M2P-TR2 monitoring relays Functions When the supply voltage U is applied, the output relay R switches into on-position (yellow LED illuminated) and the set interval of the start-up suppression (Start) begins (green LED flashes). Changes of the measured voltage during this period do not affect the state of the output relay R. After the interval has expired the green LED is illuminated steadily. For all the functions the LEDs MIN and MAX are flashing alternating, when the minimum value for the measured voltage was chosen to be greater than the maximum value. UNDER, UNDER+LATCH -...
Open the catalog to page 2Mounting Relays MR-GU1M2P-TR2 are designed for direct mounting on 35 mm rail mount acc. to PN-EN 60715. Operational position - any. Terminals - cross section of the connection cables: 1 x 0,5 ... 2,5 mm2 with/without multicore cable end, 1 x 4 mm2 without multicore cable end, 2 x 0,5 ... 1,5 mm2 with/without multicore cable end, 2 x 2,5 mm2 flexible without multicore cable end. © Supply voltage depending on the TR2 transformer which shall be ordered as a separate product - see page 4. Measuring circuit 30 V AC/DC, with fault latch mode Measuring circuit 60 V AC/DC, with fault latch mode...
Open the catalog to page 3TR2supply transformers for relays MR-G... series • Separating TR2... supply transformers for the monitoring relays of MR-G... series to reduce the input voltage applied to the terminals A1 and A2 of monitoring relays to the level required by the internal system • TR2 transformers shall be ordered as a separate product. Mounting, mechanical design TR2 supply transformers are designed for mounting in MR-G... monitoring relays and they are inseparable for their operation. MR-G... relays will not operate without the TR2... transformers. In order to mount the TR2... transformer in the monitoring...
Open the catalog to page 4All RELPOL catalogs and technical brochures
-
Interface relays
5 Pages
-
Catalogue 2021
106 Pages
-
Bistable - impulse relays
4 Pages
-
High power relays
4 Pages
-
Time relays
4 Pages
-
Monitoring relays
4 Pages
-
Relays for railroad industry
8 Pages
-
Solid state relays
4 Pages
-
RSR20
4 Pages
-
RSR30
5 Pages
-
RSR40
3 Pages
-
RSR50
10 Pages
-
RLK-1
2 Pages
-
RLK-3
2 Pages
-
Contactors
16 Pages
-
RZI60-12-M, RZI60-24-M
3 Pages
-
RZI60-24-P
3 Pages
-
NEED Programmable Relay
8 Pages
-
Signal Lamps
4 Pages
-
Time relays
12 Pages
-
Relays for electronics
16 Pages
-
Relays for industry
16 Pages
-
RM12N
3 Pages
-
MT-W...M
7 Pages
-
R2N, R3N, R4N
4 Pages
-
R40N
3 Pages
-
R30N
3 Pages
-
RSM822
3 Pages
Archived catalogs
-
Power Supplies
2 Pages
-
NEED intelligent relay
8 Pages
-
Motor circuit breakers
16 Pages
-
Contactors
36 Pages
-
Solid State Relays
28 Pages