1. Catalogs
  2. RELPOL
  3. Contactors
video corpo
cad

Contactors
1 /16Pages

Contactors

Contactors
1 /16Pages

Catalog excerpts

Contactors-2

www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 2
Contactors-3

are built in consumer devices operating in the electrical installations in: dwellings, business premises, hotels, hospitals, shopping centres, sport centres, production halls, warehouses, public places, for remote switching and automatic control of electric devices and equipment: 1-phase and 3-phase motors, different pumps, air-conditioning, electric heating, lighting. Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected] firelpols!

 Open the catalog to page 3
Contactors-4

RIK21 features • Control coil voltages of contactors: - RIK21: AC: 24 V, 230 V AC: 50/60 Hz, - RIK20 O, RIK25 O, RIK40 O, RIK63 O: AC/DC: 24 V, 230 V AC: 50/60 Hz, • Setting up contacts of contactors: - RIK20, RIK25, RIK40, RIK63: can be used as main or auxiliary contacts, - RIK25, RIK40, RIK63: additional auxiliary contacts RIKN ©, mounted on the side of the contactor. • Silent operation. • Protection against direct contact IP 20. • Compliance with standards: IEC/EN 61095, IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660, VDE 0637. • Recognitions, certifications, directives: RoHS, O RIK20, RIK25,...

 Open the catalog to page 4
Contactors-5

technical data Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 5
Contactors-6

mounting Installation contactors RIK are designed for: • direct mounting on 35 mm rail mount acc. to PN-EN 60715, • operational position - see page 11 "Mounting positions", • application site - mounted in switchboards. RIK21Output circuit - main contacts data AC6b Switching of capacitors C 230 V 36 pF Electrical life (cycles) 105 DC1 (L/R < 1 ms) Rated operational current Ie • 1 pole Ue = 24 V DC 20 A Electrical life (cycles) DC3 (L/R < 2 ms) Rated operational current Ie • 1 pole Ue = 24 V DC 10 A Electrical life (cycles) 105 www.relpol.com.pl Export Sales Department...

 Open the catalog to page 6
Contactors-7

technical data Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected] firelpol

 Open the catalog to page 7
Contactors-8

o Q. Output circuit - main contacts data Insulation rated voltage Ui Rated surge voltage Uimp Rated thermal current Ith Rated operational voltage Ue AC15 Rated operational current 230 V Electrical life (cycles) Input circuit - coil data u re RIKN-20 RIKN-11 O RIK20, RIK25, RIK40, RIK63: contactors with a varistor for overvoltage protection and a rectifier enable DC and AC voltage control a RIK20, RIK25: contactors can be controlled by AC voltage with frequency 40 ... 400 Hz Control voltage Uc Range of control voltage Uc Rated frequency f Surge immunity test (IEC/EN 61000-4-5) switch-on operation make break Max....

 Open the catalog to page 8
Contactors-9

technical data series-motors: starting, plugging, inching, dynamic breaking of motors Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected] firelpol

 Open the catalog to page 9
Contactors-10

www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 10
Contactors-11

dimensions, mounting positions dimensions, mounting positions contactors RIK40, RIK63auxiliary contacts RIKN o 60 O RIKN increase by 9 mm the width of contactors RIK25, RIK40, RIK63 © RIK21: mounting position of contactor is optional Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 11
Contactors-12

Control of lighting circuits Power [W] RIK21 RIK20 RIK25 RIK40 RIK63 Incandescent lamps and tungsten halogen lamps www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 12
Contactors-13

Power Current Capacitance High-pressure mercury-vapour lamps Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected] firelpol

 Open the catalog to page 13
Contactors-14

Power Current Capacitance www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 14
Contactors-15

maximum number of lamps on each pole contactor at 230 V 50 Hz Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]

 Open the catalog to page 15
Contactors-16

subminiature signal relays rated switching capacity: from 0,5 A to 3 A, coil voltage range: from 3 V to 48 V DC miniature relays rated switching capacity: from 5 A to 20 A industrial relays rated switching capacity: from 5 A to 48 A, mounting: to plug-in sockets on 35 mm rail mount acc. to PN-EN 60715 or on panel mounting, for PCB interface relays rated switching capacity: from 0,05 A to 16 A, number of contacts: from 1 to 4 programmable relays NEED versions: 8 inputs / 4 outputs, 16 inputs / 8 outputs, with LCD display, without display, supply voltages: 12 V DC, 24 V DC, 220 V DC, 230 V AC, programming:...

 Open the catalog to page 16

All RELPOL catalogs and technical brochures

  1. Catalogue 2021

    106  Pages

  2. Time relays

    4  Pages

  3. MR-GU1M2P-TR2

    4  Pages

  4. RSR20

    4  Pages

  5. RSR30

    5  Pages

  6. RSR40

    3  Pages

  7. RSR50

    10  Pages

  8. RLK-1

    2  Pages

  9. RLK-3

    2  Pages

  10. RZI60-24-P

    3  Pages

  11. Signal Lamps

    4  Pages

  12. Time relays

    12  Pages

  13. RM12N

    3  Pages

  14. MT-W...M

    7  Pages

  15. R2N, R3N, R4N

    4  Pages

  16. R40N

    3  Pages

  17. R30N

    3  Pages

  18. RSM822

    3  Pages

Archived catalogs

  1. Contactors

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.