REGUPOL VIBRATION 450 - 1

— REGUPOL Forms of delivery, ex warehouse Plates Thickness: 25 and 50 mm, special thicknesses available Length: 1,000 mm Technical Details Maximum static load bearing capacity 0.120 N/mm* Rare, short term peak loads up to 0.180 N/mm2 Physical property Norm Static modulus of elasticity Based on EN 826 Dynamic modulus of elasticity Based on DIN 53513 Mechanical loss factor DIN 53513 DIN EN ISO 1856 Tensile strength Based on DIN EN ISO 1798 Elongation at break Based on DIN EN ISO 1798 Tear resistance Based on DIN ISO 34-1 DIN EN 13501 Sliding friction REGUPOL-laboratory REGUPOL-laboratory Compression hardness Based on DIN EN ISO 3386-2 Rebound elasticity Based on Result Comment 0.2 - 0.4 N/mm* Tangential modulus, see figure “Modulus of elasticity” 0.45 - 2.70 N/mm* Depending on frequency, load and thickness, see figure “dynamic stiffness” 0.17 Load-, amplitude- and frequency-dependent 4.1 % Measured 30 minutes after decompression with 50% deformation / 23 °C after 72 hrs E acceptable fire behaviour 83 kPa Compressive stress at 25 % deformation test specimen h = 50 mm 42.7 % dependent on thickness, test specimen h = 50 mm 74 % dependent on thickness, test specimen h = 50 mm Cracking stage 0 Technical Data | REGUPOL vibration 450 | Release 06.04.2021 | www.regupol.com

Open the catalog to page 1
REGUPOL VIBRATION 450 - 2

Pressure [N/mm2] Maximum static load bearing capacity in N/mm2 Deflection [mm] Examination of deflection in accordance to DIN EN 826 between two stiff panels. Illustration based on the third loading. Velocity of loading and unloading 20 seconds. Tested at room temperature. Dimensions of test specimens 300 x 300 mm. Technical Data | REGUPOL vibration 450 | Release 06.04.2021 | www.regupol.com

Open the catalog to page 2
REGUPOL VIBRATION 450 - 3

Vibration Isolation Natural frequency [Hz] Dargestellt of the isolation efficiencyeinen Ein-Massen-Schwinger auf starrem Untergrundon Illustration ist die Isolierwirkung für of a single-degree-of-freedom system (SDOF system) mit Regufoam® vibration 150 plus. Parameter: Kraftübertragungsmaß in dB, Isolierwirkungsgrad in %. a rigid base with REGUPOL vibration 450. Parameter: power transmission (insertion loss) in dB, isolation factor in %. Natural Frequency Natural frequency [Hz] Natural frequency of a für einen eindimensionalen Feder-Masse-Schwinger unter Berücksichtigung der...

Open the catalog to page 3
REGUPOL VIBRATION 450 - 4

Change of mechanical loss factor [%] Change of dynamic stiffness [%] Difference in natural frequency [%] Amplitude [pm] Change of the dynamic stiffness due to changes in amplitudes. Average for 5 Hz, 10 Hz and 40 Hz excitation. Sinusoidal excitation at a constant mean load of 0.10 N/mm2 dimensions of the specimens 300 x 300 x 50 mm. Natural frequency of a single-degree-of-freedom system (SDOF system) on a rigid base. Amplitude [pm] Change of the mechanical loss factor due to changes in amplitudes. Sinusoidal excitation at a constant mean load of 0.10 N/mm!, dimensions of the specimens 300 x...

Open the catalog to page 4
REGUPOL VIBRATION 450 - 5

Pressure [N/mm²] Illustration of the dynamic modulus of elasticity for sinusoidal excitation at a constant mean load and an amplitude of ± 0.25 mm. Dimensions of specimens 300 x 300 x 50 mm; static modulus of elasticity as a result of the tangent modulus of the spring characteristic. Tested in accordance with DIN 53513. Dynamic Stiffness Pressure [N/mm²] Illustration of the dynamic stiffness for sinusoidal excitation at a constant mean load and an amplitude of ± 0.25 mm. Dimensions of specimens 300 x 300 x 50 mm; static stiffness as a result of the tangent m odulus of the spring...

Open the catalog to page 5
REGUPOL VIBRATION 450 - 6

Long-Term Creep Test Duration of load [h] Dimensions of specimens 300 x 300 x 50 mm Exclusion of Liability Technical services and offers based on these are subject to our General Terms and Conditions of sale, a copy of which can be found on our website www. berleburger.com. Special attention should be paid to paragraphs 4 and 5. In so far, please be advised as follows: Our expertise is the development and manufacturing of products. With our recommendation we can only assist you in selecting a product that is suitable for your demand. However, we cannot act as your architect or consulting...

Open the catalog to page 6