Overview: The LOW E TESTER RG-306 is a device designed to detect the conductive side of special glass used in glazing. This ensures that the glass is installed correctly to maintain its functional properties.
Specifications: The tester requires 3 AAA batteries, which are not included for delivery safety. It features a power switch and multiple LEDs for operation indication.
Procedures:
  • Disassemble the bottom plate to insert batteries, ensuring the semi-circle groove is not perpendicular to the power switch to prevent damage.
  • Ensure internal wiring is not obstructed during reassembly.
  • When not in use, turn off the power switch to deactivate the 3 center LEDs.
  • In standby mode, the 3 center LEDs will be illuminated.
  • To test, place the tester against the glass and apply slight pressure. If all LEDs except the center ones illuminate and a beep is heard, the tested side is conductive.
Recommendations: Field workers should carry this tester to verify the conductive coating of glass before installation to avoid incorrect glazing.
See more

Catalog excerpts

LOW E TESTER RG-306-1

LOW E TESTER RG-306 ( Detecter for Conductive side of Special Glass ) In Glazing Special functional glass coated with Conductive matter If coated side is wrongfully installed, expected function of special glass is lost and should glaze it inside out again. For convenience of field workers who glaze specail glass, by carrying this tester to check whether glazed side of glass has conductive coating. Actual Size Figure. Disassembled RG-306 ( Reference: batteries are not included for delivery safety) * Direction 1. Disassemble screws at the bottom plate, and insert 3 AAA batteries, then please make sure semi circle groove on the bottom plate should not be perpendicular with power switch in black circle to avoid damage also please confirm inside wiring should not be stuck by bottom plate during assembly of bottom plate. 2. When tester is not used, please make sure to push power switch in black circle for 3 center LEDs to turn off 3. In standby condition, 3 center LEDs will shine. 4. There are contacts at the bottom of tester, please place tester on side and slighly push tester against a glass. 5. If all LEDs shine except for 3 center LEDs and make a beep sound, tested side has a conductive side.

 Open the catalog to page 1

All REGEN-I Company catalogs and technical brochures

  1. RG-513

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.